Preliminary Research on Effective Length of Concrete Filled Steel Tubular Columns in Sway Frame

被引:0
作者
Shi, Yanli [1 ,2 ]
Wang, Feng [2 ]
Wang, Wenda [1 ,2 ]
机构
[1] Lanzhou Univ Technol, Key Lab Disaster Prevent & Mitigat Civil Engn Gan, Lanzhou 730050, Peoples R China
[2] Lanzhou Univ Technol, Coll Civil Engn, Lanzhou 730050, Peoples R China
来源
TRENDS IN CIVIL ENGINEERING, PTS 1-4 | 2012年 / 446-449卷
关键词
concrete filled steel tube (CFST); frame columns; sway frame; effective length factor; finite element method (FEM); linear buckling analysis; non-linear buckling analysis;
D O I
10.4028/www.scientific.net/AMR.446-449.318
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The effective length of concrete filled steel tubular (CFST) frame columns is a key parameter to determine its ultimate strength for engineering design. There was no special design code, so engineers usually got the values according with specification for steel structure. This may cause error in some degree. Based on liner and non-linear buckling analysis respectively, the overall stability of a typical planar composite frame with CFST columns and steel beams was performed in this paper. By comparing the results of finite element method with current approach, some primary conclusions were given to refer for engineering practice on the composite frames.
引用
收藏
页码:318 / +
页数:2
相关论文
共 11 条
[1]  
AIJ, 1997, Recommendations for Design and Construction of Concrete Filled Steel Tubular Structures
[2]  
[Anonymous], 2010, AISC 360-10
[3]  
[Anonymous], 62T2530412009 DB ENG
[4]  
Chen J, 2006, Stability of steel structures theory and design
[5]  
Chen WF., 1991, Stability Design of Steel Frames
[6]  
Eurocode4, 2004, 1994112004 BS EN
[7]  
GB, GB50017-2003
[8]  
Shen Shizhao, 1999, STABILITY SPHERICAL
[9]  
Wang Wenda, 2005, J HARBIN I TECHNOLOG, V37, P167
[10]  
Xu Peifu, 2005, DESIGN COMPLEX TALL