Development of a combined audiovisual and extremity dose monitoring software tool for use in nuclear medicine

被引:0
|
作者
Guy, MJ [1 ]
Greaves, CD [1 ]
Morton, RJ [1 ]
Hinton, PJ [1 ]
机构
[1] Royal Surrey Cty Hosp, Dept Med Phys Nucl Med, Guildford GU2 7XX, Surrey, England
关键词
extremity dose; radionuclide therapy; radiopharmaceutical dispensing; radiopharmacy;
D O I
10.1097/00006231-200512000-00016
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives Conventional extremity dose monitoring in nuclear medicine, using thermoluminescent dosimeters, provides a convenient method of determining integral doses from a series of procedures. Although semiconductor extremity probes are able to add time information and allow doses from individual procedures to be determined, it can be difficult to relate individual operations to the dose-time curve. Solutions to this problem have been identified and developed. Methods A novel software tool (Extremity Dose Information Package, EDIP) has been developed that uniquely combines and synchronizes two audiovisual and extremity probe data-streams. The value of this extra information was assessed by acquiring audiovisual and extremity dose information in nuclear medicine and radiopharmacy settings. Results The ability of the software tool to synchronize audiovisual and dose data-streams was verified. Preliminary studies of handling techniques in radiopharmacy and radioiodine administrations using this tool showed areas in which techniques could be adapted to reduce extremity doses, which would have been difficult or impossible to identify using the dose-time information alone. Conclusions This low-cost multimedia extremity dose monitoring package can be used, for example, to aid staff training and pinpoint issues with current operating procedures within a clinical nuclear medicine department. Its unique ability to combine and synchronize audiovisual and dosimetry data is also likely to be of benefit to other industries handling unsealed radioactive materials. Nucl Med Commun 26:1147-1153 (c) 2005 Lippincott Williams & Wilkins.
引用
收藏
页码:1147 / 1153
页数:7
相关论文
共 50 条
  • [31] A software tool for monitoring the features of convective cloud systems with the use of Meteosat images
    Feidas, H
    ENVIRONMENTAL MODELLING & SOFTWARE, 2003, 18 (01) : 1 - 12
  • [32] Quality optimization of slab casting with use of software monitoring tool and statistical methods
    Franek, Zdenek
    Masarik, Milos
    PROCEEDINGS OF 30TH INTERNATIONAL CONFERENCE MATHEMATICAL METHODS IN ECONOMICS, PTS I AND II, 2012, : 178 - +
  • [33] Development and evaluation of a dynamic cardiac phantom for use in nuclear medicine
    Dullius, Marcos A.
    Fernandes, Ramon C.
    Souza, Divanízia N.
    World Academy of Science, Engineering and Technology, 2011, 80 : 342 - 345
  • [34] Development of accident dose consequences simulation software for nuclear emergency response applications
    Cheng, Yi-Hsiang
    Shih, Chunkuan
    Jiang, Sow-Chyuang
    Weng, Tong-Li
    ANNALS OF NUCLEAR ENERGY, 2008, 35 (05) : 917 - 926
  • [35] Calculating equivalent dose received from a patient undergoing nuclear medicine procedure by merge phantoms tool and GAMOS/Geant4 6.0.0 software
    Nguyen Thi Phuong Thao
    Nguyen Thien Trung
    Nguyen Dong Son
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 68 : 41 - 46
  • [36] Cloud Environment for Development and Use of Software Systems for Clinical Medicine and Education
    Gribova, Valeria
    Moskalenko, Philip
    Petryaeva, Margaret
    Okun, Dmitry
    PROCEEDINGS OF THE 7TH SCIENTIFIC CONFERENCE ON INFORMATION TECHNOLOGIES FOR INTELLIGENT DECISION MAKING SUPPORT (ITIDS 2019), 2019, 166 : 225 - 229
  • [37] USE OF THERMOLUMINESCENT DOSIMETERS FOR MEASUREMENT OF DOSE TO HANDS OF NUCLEAR-MEDICINE TECHNICIANS
    ANDERSON, DW
    ADAMS, GD
    RICHTER, CW
    FICKEN, VJ
    JOURNAL OF NUCLEAR MEDICINE, 1972, 13 (08) : 627 - &
  • [38] Development of a commissioning tool to implement a proton independent dose calculation software at MedAustron (MA)
    Scheuchenpflug, L.
    Carlino, A.
    Elia, A.
    Boersma, D. J.
    Fuchs, H.
    Stock, M.
    Grevillot, L.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2020, 196 (03) : 312 - 312
  • [39] Combined Use of a Patient Dose Monitoring System and a Real-Time Occupational Dose Monitoring System for Fluoroscopically Guided Interventions
    Heilmaier, Christina
    Kara, Levent
    Zuber, Niklaus
    Berthold, Christian
    Weishaupt, Dominik
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2016, 27 (04) : 584 - 592
  • [40] A COMBINED SOFTWARE HARDWARE DEVELOPMENT TOOL FOR THE TMS32020 DIGITAL SIGNAL PROCESSOR
    CHANCE, RJ
    JONES, BS
    JOURNAL OF MICROCOMPUTER APPLICATIONS, 1987, 10 (03): : 179 - 197