Late haemodynamic and functional consequences of radial artery removal on the forearm circulation

被引:8
作者
Gaudino, Mario [1 ]
Anselmi, Amedeo [1 ]
Serricchio, Michele [2 ]
Flore, Roberto [2 ]
Santoliquido, Angelo [2 ]
Gerardino, Laura [2 ]
Pola, Roberto [2 ]
Possati, Gian Federico [1 ]
Tondi, Paolo [2 ]
机构
[1] Catholic Univ, Dept Cardiac Surg, Rome, Italy
[2] Catholic Univ, Dept Angiol, Rome, Italy
关键词
radial artery; coronary artery bypass surgery; hand function;
D O I
10.1016/j.ijcard.2007.07.096
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: We aimed at evaluating the late haemodynamic and functional consequences on the forearm circulation of radial artery removal for coronary artery bypass grafting. Methods: Ten years after surgery we performed basal and stress echo-Doppler evaluation of the forearm circulation, baseline and stress transcutaneous oxymetry and determination of reactive oxygen metabolites in the operated and control arm in 20 asymptomatic patients submitted to radial artery removal. Results: The peak systolic velocity of the ulnar artery of the operated side was significantly higher than the control site. Transcutaneous oxymetry revealed asymptomatic hand ischemia at moderate level of muscular effort in the operated arm, but reactive oxygen metabolites measurement did not differ between the two arms. Conclusions: Even in patients with good ulnar compensation, radial artery removal leads to subtle degree of hand ischemia in conditions of sustained muscular effort. Although the clinical significance of this observation remains to be determined, this finding can have important implications for conduit selection in patients involved in manual activities. (C) 2007 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:255 / 258
页数:4
相关论文
共 18 条
[1]   Duplex ultrasonography predicts safety of radial artery harvest in the presence of an abnormal Allen test [J].
Abu-Omar, Y ;
Mussa, S ;
Anastasiadis, K ;
Steel, S ;
Hands, L ;
Taggart, DP .
ANNALS OF THORACIC SURGERY, 2004, 77 (01) :116-119
[2]   The radial artery for coronary artery bypass grafting: Clinical and angiographic results at five years [J].
Acar, C ;
Ramsheyi, A ;
Pagny, JY ;
Jebara, V ;
Barrier, P ;
Fabiani, JN ;
Deloche, H ;
Guermonprez, JL ;
Carpentier, A .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1998, 116 (06) :981-988
[3]  
Chambless LE, 1997, AM J EPIDEMIOL, V146, P483, DOI 10.1093/oxfordjournals.aje.a009302
[4]   Early postoperative angiographic assessment of radial artery grafts used for coronary artery bypass grafting [J].
Chen, AH ;
Nakao, T ;
Brodman, RF ;
Greenberg, M ;
Charney, R ;
Menegus, M ;
Johnson, M ;
Grose, R ;
Frame, R ;
Hu, EC ;
Choi, HK ;
Safyer, S .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1996, 111 (06) :1208-1212
[5]   Long saphenous vein stripping reduces local level of reactive oxygen metabolites in patients with varicose disease of the lower limbs [J].
Flore, R ;
Santoliquido, A ;
Antonio, DL ;
Pola, E ;
Flex, A ;
Pola, R ;
Muzi, MG ;
Farinon, A ;
Rulli, F ;
Gaetani, E ;
Tondi, P ;
Gerardino, L ;
Gasbarrini, A .
WORLD JOURNAL OF SURGERY, 2003, 27 (04) :473-475
[6]   Midterm endothelial function and remodeling of radial artery grafts anastomosed to the aorta [J].
Gaudino, M ;
Glieca, F ;
Trani, C ;
Lupi, A ;
Mazzari, MA ;
Schiavoni, G ;
Possati, G .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2000, 120 (02) :298-301
[7]   Chronic compensatory increase in ulnar flow and accelerated atherosclerosis after radial artery removal for coronary artery bypass [J].
Gaudino, M ;
Serricchio, M ;
Tondi, P ;
Gerardino, L ;
Di Giorgio, A ;
Pola, P ;
Possati, G .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2005, 130 (01) :9-12
[8]   Effect of target artery location and severity of stenosis on mid-term patency of aorta-anastomosed vs. internal thoracic artery-anastomosed radial artery grafts [J].
Gaudino, M ;
Alessandrini, F ;
Pragliola, C ;
Cellini, C ;
Glieca, F ;
Luciani, N ;
Girola, F ;
Possati, G .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2004, 25 (03) :424-428
[9]   A methodological study of arterial wall function using ultrasound technique [J].
JensenUrstad, K ;
Rosfors, S .
CLINICAL PHYSIOLOGY, 1997, 17 (06) :557-567
[10]   Oxygen pressure measurement during grip exercise reveals exercise intolerance after radial harvest [J].
Manabe, S ;
Tabuchi, N ;
Toyama, M ;
Yoshizaki, T ;
Kato, M ;
Wu, HS ;
Kotani, M ;
Sunamori, M .
ANNALS OF THORACIC SURGERY, 2004, 77 (06) :2066-2070