Microwave-assisted solid phase extraction prior to ICP-MS determination of Pd and Pt in environmental and biological samples

被引:6
|
作者
Kovachev, N. [1 ,2 ]
Sanchez, A. [3 ]
Simitchiev, K. [4 ]
Stefanova, V. [4 ]
Kmetov, V. [4 ]
Canals, A. [1 ,2 ]
机构
[1] Univ Alicante, Dept Quim Analit Nutr & Bromatol, E-03080 Alicante, Spain
[2] Univ Alicante, Inst Univ Mat, E-03080 Alicante, Spain
[3] Ctr Salud Publ, Lab Salud Publ Alicante, Alicante, Spain
[4] Paisij Hilendarski Univ Plovdiv, Dept Analyt Chem, BG-4000 Plovdiv, Bulgaria
关键词
microwave-assisted solid phase extraction; ICP-MS; palladium determination; platinum determination; environmental samples; biological samples; PLATINUM-GROUP ELEMENTS; ATOMIC-ABSORPTION-SPECTROMETRY; PLASMA-MASS SPECTROMETRY; AIRBORNE PARTICULATE MATTER; ONLINE PRECONCENTRATION; ROAD DUST; SILICA-GEL; CATALYTIC-CONVERTERS; ANALYTICAL-CHEMISTRY; GROUP METALS;
D O I
10.1080/03067319.2010.534158
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive and selective microwave-assisted solid phase extraction procedure coupled to inductively coupled plasma-mass spectrometry (ICP-MS) is proposed for palladium (Pd) and platinum (Pt) quantification in environmental and biological samples. Pd and Pt were quantitatively retained on commercial thioureido propyl functionalised silica gel packed inside a home-made glass microcolumn, and later eluted with 0.5% thiourea solution under microwave irradiation, followed by ICP-MS determination. The main variables affecting the procedural stages (i.e., sorption and desorption) and ICP-MS determination were optimised. The best conditions found were: (a) sorption: sample acidity, 1 M HCl; sample flow rate, 3 mL min(-1); (b) desorption: microwave radiation, power 800 W; eluent concentration, 0.5% thiourea; eluent flow rate, 0.5 mL min(-1); (c) ICP-MS determination: nebuliser feeding, free aspiration (0.3 mL min(-1)); internal standard, Rh (5 mg L-1). Analyte recoveries were higher than 90% and concentration factors up to 90 and 92 were achieved for Pd and Pt, respectively. Depending on the conditions, the methodological limits of detection were down to 0.2 ng L-1 for both analytes and repeatability, expressed as RSD%, varied between 1.3 and 11.0%. A method selectivity evaluation showed that most of the ICP-MS interferents were either quantitatively separated or more than 86% eliminated, except for Cu (elimination efficiency around 30%). Finally, the method was successfully used to determine Pd in certified reference materials (i.e. human urine and serum) and Pd and Pt in PM10 airborne particulate matter fractions.
引用
收藏
页码:1106 / 1119
页数:14
相关论文
共 50 条
  • [1] ICP-MS multispeciation in certified environmental samples after microwave-assisted sequential extraction
    Dutta, M
    Chandrasekhar, K
    Das, AK
    ATOMIC SPECTROSCOPY, 2005, 26 (01) : 14 - 18
  • [2] Comparison of Microwave-Assisted Digestion Methods and Selection of Internal Standards for the Determination of Rh, Pd and Pt in Dust Samples by ICP-MS
    Matti Niemelä
    Harri Kola
    Paavo Perämäki
    Juha Piispanen
    Jarmo Poikolainen
    Microchimica Acta, 2005, 150 : 211 - 217
  • [3] Comparison of microwave-assisted digestion methods and selection of internal standards for the determination of Rh, Pd and Pt in dust samples by ICP-MS
    Niemelä, M
    Kola, H
    Perämäki, P
    Piispanen, J
    Poikolainen, J
    MICROCHIMICA ACTA, 2005, 150 (3-4) : 211 - 217
  • [4] Determination of Pt from coke samples by ICP-MS after microwave assisted digestion and microwave assisted cloud point extraction
    Matti Niemelä
    Satu M. Huttunen
    Stanislav S. Gornostayev
    Paavo Perämäki
    Microchimica Acta, 2009, 166 : 255 - 260
  • [5] Determination of Pt from coke samples by ICP-MS after microwave assisted digestion and microwave assisted cloud point extraction
    Niemela, Matti
    Huttunen, Satu M.
    Gornostayev, Stanislav S.
    Peramaki, Paavo
    MICROCHIMICA ACTA, 2009, 166 (3-4) : 255 - 260
  • [6] Determination of Au, Pt and Pd in Biology Samples by ICP-MS
    Yu, Jing
    ASIAN JOURNAL OF CHEMISTRY, 2012, 24 (06) : 2831 - 2832
  • [7] ICP-MS multielement determination in fly ash after microwave-assisted digestion of samples
    Das, AK
    Chakraborty, R
    de la Guardia, M
    Cervera, ML
    Goswami, D
    TALANTA, 2001, 54 (05) : 975 - 981
  • [8] Fast and selective magnetic solid phase extraction of trace Cd, Mn and Pb in environmental and biological samples and their determination by ICP-MS
    Zhang, Nan
    Peng, Hanyong
    Wang, Shen
    Hu, Bin
    MICROCHIMICA ACTA, 2011, 175 (1-2) : 121 - 128
  • [9] Microwave-assisted cloud point extraction of Rh, Pd and Pt with 2-mercaptobenzothiazole as preconcentration procedure prior to ICP-MS analysis of pharmaceutical products
    Simitchiev, Kiril
    Stefanova, Violeta
    Kmetov, Veselin
    Andreev, George
    Kovachev, Nikolay
    Canals, Antonio
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2008, 23 (05) : 717 - 726
  • [10] Fast and selective magnetic solid phase extraction of trace Cd, Mn and Pb in environmental and biological samples and their determination by ICP-MS
    Nan Zhang
    Hanyong Peng
    Shen Wang
    Bin Hu
    Microchimica Acta, 2011, 175 : 121 - 128