Real-time monitoring of ozone in air using substrate-integrated hollow waveguide mid-infrared sensors

被引:41
作者
da Silveira Petruci, Joao Flavio [1 ,2 ]
Fortes, Paula Regina [2 ,3 ]
Kokoric, Vjekoslav [2 ]
Wilk, Andreas [2 ]
Raimundo, Ivo Milton, Jr. [3 ]
Cardoso, Arnaldo Alves [1 ]
Mizaikoff, Boris [2 ]
机构
[1] Sao Paulo State Univ, Dept Analyt Chem, UNESP, BR-14800970 Araraquara, SP, Brazil
[2] Univ Ulm, Inst Analyt & Bioanalyt Chem, D-89081 Ulm, Germany
[3] Univ Estadual Campinas, Dept Analyt Chem, UNICAMP, Campinas, SP, Brazil
来源
SCIENTIFIC REPORTS | 2013年 / 3卷
基金
巴西圣保罗研究基金会;
关键词
INDOOR ENVIRONMENTS; BACTERIA; LIGHT;
D O I
10.1038/srep03174
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Ozone is a strong oxidant that is globally used as disinfection agent for many purposes including indoor building air cleaning, during food preparation procedures, and for control and killing of bacteria such as E. coli and S. aureus. However, it has been shown that effective ozone concentrations for controlling e. g., microbial growth need to be higher than 5 ppm, thereby exceeding the recommended U. S. EPA threshold more than 10 times. Consequently, real-time monitoring of such ozone concentration levels is essential. Here, we describe the first online gas sensing system combining a compact Fourier transform infrared (FTIR) spectrometer with a new generation of gas cells, a so-called substrate-integrated hollow waveguide (iHWG). The sensor was calibrated using anUVlamp for the controlled generation of ozone in synthetic air. Acalibration function was established in the concentration range of 0.3-5.4 mmolm23 enabling a calculated limit of detection (LOD) at 0.14 mmol m23 (3.5 ppm) of ozone. Given the adaptability of the developed IR sensing device toward a series of relevant air pollutants, and considering the potential for miniaturization e.g., in combination with tunable quantum cascade lasers in lieu of the FTIR spectrometer, a wide range of sensing and monitoring applications of beyond ozone analysis are anticipated.
引用
收藏
页数:5
相关论文
共 37 条
  • [21] Ozone reactions with indoor materials during building disinfection
    Poppendieck, D.
    Hubbard, H.
    Ward, M.
    Weschler, C.
    Corsi, R. L.
    [J]. ATMOSPHERIC ENVIRONMENT, 2007, 41 (15) : 3166 - 3176
  • [22] FAST-RESPONSE DUAL-BEAM UV-ABSORPTION OZONE PHOTOMETER SUITABLE FOR USE ON STRATOSPHERIC BALLOONS
    PROFFITT, MH
    MCLAUGHLIN, RJ
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1983, 54 (12) : 1719 - 1728
  • [23] RIDLEY BA, 1992, J ATMOS OCEAN TECH, V9, P142, DOI 10.1175/1520-0426(1992)009<0142:ASHSMR>2.0.CO
  • [24] 2
  • [25] ATTENUATION OF INCOHERENT INFRARED RADIATION IN HOLLOW SAPPHIRE AND SILICA WAVE-GUIDES
    SAGGESE, SJ
    HARRINGTON, JA
    SIGEL, GH
    [J]. OPTICS LETTERS, 1991, 16 (01) : 27 - 29
  • [26] PRINCIPLE AND APPLICATION OF A FAST SENSOR FOR ATMOSPHERIC OZONE
    SCHURATH, U
    SPEUSER, W
    SCHMIDT, R
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1991, 340 (09): : 544 - 547
  • [27] Use of ozone to reduce molds in a cheese ripening room
    Serra, R
    Abrunhosa, L
    Kozakiewicz, Z
    Venâncio, A
    Lima, N
    [J]. JOURNAL OF FOOD PROTECTION, 2003, 66 (12) : 2355 - 2358
  • [28] EFFECTIVENESS OF PORTABLE INDOOR AIR CLEANERS - SENSORY TESTING RESULTS
    SHAUGHNESSY, RJ
    LEVETIN, E
    BLOCKER, J
    SUBLETTE, KL
    [J]. INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1994, 4 (03): : 179 - 188
  • [29] Stern A. C., 1976, AIR POLLUTION MEASUR
  • [30] Determination of ozone emission from a domestic air cleaner and decay parameters using environmental chamber tests
    Tung, TCW
    Niu, JL
    Burnett, J
    Hung, K
    [J]. INDOOR AND BUILT ENVIRONMENT, 2005, 14 (01) : 29 - 37