The reliability of postural balance measures in single and dual tasking in elderly fallers and non-fallers

被引:98
作者
Swanenburg, Jaap [1 ,2 ]
de Bruin, Eling D. [1 ,2 ,3 ]
Favero, Kathrin [3 ]
Uebelhart, Daniel [1 ,2 ,4 ]
Mulder, Theo [5 ,6 ]
机构
[1] Univ Zurich Hosp, Dept Rheumatol, CH-8091 Zurich, Switzerland
[2] Univ Zurich Hosp, Inst Med Phys, CH-8091 Zurich, Switzerland
[3] ETH, Inst Human Movement Sci & Sport, Zurich, Switzerland
[4] Univ Zurich Hosp, Ctr Osteoporosis, CH-8091 Zurich, Switzerland
[5] Royal Netherlands Acad Arts & Sci, Amsterdam, Netherlands
[6] Univ Groningen, Univ Med Ctr Groningen, Ctr Human Movement Sci, NL-9713 AV Groningen, Netherlands
关键词
D O I
10.1186/1471-2474-9-162
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The purpose of this study was to determine the reliability of a forceplate postural balance protocol in a group of elderly fallers and non-fallers. The measurements were tested in single and dual-task conditions, with and without vision. Methods: 37 elderly (mean age 73 +/- 6 years) community-dwellers were included in this study. All were tested in a single (two-legged stance) and in a dual-task (two-legged stance while counting backwards aloud in steps of 7's) condition, with and without vision. A forceplate was used for registering postural variables: the maximal and the root-mean-square amplitude in medio-lateral (Max-ML, RMS-ML) and antero-posterior (Max-AP, RMS-AP) direction, mean velocity (MV), and the area of the 95% confidence ellipse (AoE). Reliability of the test protocol was expressed with intraclass correlation coefficients (ICC), with 95% limits of agreement (LoA), and with the smallest detectable difference (SDD). Results: The ICCs for inter-rater reliability and test-retest reliability of the balance variables were r = 0.70-0.89. For the variables Max-AP and RMS-AP the ICCs were r = 0.52-0.74. The SDD values were for variable Max-ML and Max-AP between 0.37 cm and 0.83 cm, for MV between 0.48 cm/s and 1.2 cm/s and for AoE between 1.48 cm(2) and 3.75 cm(2). The LoA analysis by Bland-Altman plots showed no systematic differences between test-retest measurements. Conclusion: The study showed good reliability results for group assessment and no systematic errors of the measurement protocol in measuring postural balance in the elderly in a single-task and dual-task condition.
引用
收藏
页数:10
相关论文
共 50 条
[41]   Predicting the probability for falls in community-dwelling older adults [J].
ShumwayCook, A ;
Baldwin, M ;
Polissar, NL .
PHYSICAL THERAPY, 1997, 77 (08) :812-819
[42]   A rapid upward step challenges medio-lateral postural stability [J].
Sims, KJ ;
Brauer, SG .
GAIT & POSTURE, 2000, 12 (03) :217-224
[43]   Interobserver reproducibility of the assessment of severity of complaints, grip strength, and pressure pain threshold in patients with lateral epicondylitis [J].
Smidt, N ;
van der Windt, DA ;
Assendelft, WJ ;
Mourits, AJ ;
Devillé, WL ;
de Winter, AF ;
Bouter, LM .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2002, 83 (08) :1145-1150
[44]  
SPIRDUSO WW, 1995, BALANCE POSTURE LOCO, P155
[45]  
Stelmach G E, 1985, Clin Geriatr Med, V1, P679
[46]  
Stelmach G E, 1990, Aging (Milano), V2, P155
[47]   RELIABILITY - CONSISTENCY OR DIFFERENTIATING AMONG SUBJECTS [J].
STRATFORD, P .
PHYSICAL THERAPY, 1989, 69 (04) :299-300
[48]   RISK-FACTORS FOR FALLS AMONG ELDERLY PERSONS LIVING IN THE COMMUNITY [J].
TINETTI, ME ;
SPEECHLEY, M ;
GINTER, SF .
NEW ENGLAND JOURNAL OF MEDICINE, 1988, 319 (26) :1701-1707
[49]  
Wickens C. D., 1984, PROCESSING RESOURCES, P63
[50]  
WING A.M., 1995, GAIT POSTURE, V3, P38, DOI [10.1016/0966-6362(95)90807-5, DOI 10.1016/0966-6362(95)90807-5]