Purpose: Breast specific gamma imaging or molecular breast imaging (BSGI) obtains 2D images of Tc-99m sestamibi distribution in the breast. Molecular breast tomosynthesis (MBT) maps the tracer distribution in 3D by acquiring multiple projections over a limited angular range. Here, the authors compare the performance of the two technologies in terms of spatial resolution, lesion contrast, and contrast-to-noise ratio (CNR) in phantom studies under conditions of clinically relevant sestamibi dose and imaging time. Methods: The systems tested were a Dilon 6800 and a MBT prototype developed at the University of Virginia. Both systems comprise a pixelated sodium iodide scintillator, an array of position sensitive photomultipliers, and a parallel hole collimator. The active areas and energy resolution of the systems are similar. System sensitivity, spatial resolution, lesion contrast, and CNR were measured using a Petri dish, a point source phantom, and a breast phantom containing simulated lesions at two depths, respectively. A single BSGI projection was acquired. Five MBT projections were acquired over +/- 20 degrees. For both modalities, the total scan count density was comparable to that observed for each in typical 10 min human scans following injection of 22 mCi (814 MBq) of Tc-99m-sestamibi. To assess the impact of reducing the tracer dose, the pixel counts of projection images were later binomially subsampled by a factor of 2 to give images corresponding to an injected activity of approximately 11 mCi (407 MBq). Both unprocessed (pixelated) BSGI projections and interpolated (smoothed) BSGI images displayed by default on the Dilon 6800 workstation were analyzed. Volumetric images were reconstructed from the MBT projections using a maximum likelihood expectation maximization algorithm and extracted slices were analyzed. Results: Over a depth range of 1.5-7.5 cm, BSGI spatial resolution was 5.6-11.5 mm in unprocessed projections and 5.7-12.0 mm in interpolated images. Over the same range, the in-slice MBT spatial resolution was 6.7-9.4 mm. Lesion contrast was significantly improved with MBT relative to BSGI for five out of eight lesions imaged at either the 22 mCi or the 11 mCi dose level (p < 0.05). At both dose levels, significant improvements in CNR with MBT were also found for five out of eight lesions (9.8, 7.8, 6.2 mm lesions at water depth of 1.7 cm and 9.8, 7.8 mm lesions at water depth of 4.5 cm, p < 0.05). The 6.2 and 4.9 mm lesions located at 4.5 cm below the water surface were not visible in either modality at either activity level. Conclusions: Under conditions of equal dose, imaging time and similar detectors, compared to BSGI, MBT provided higher lesion contrast, higher CNR, and spatial resolution that was less depth dependent. (C) 2015 American Association of Physicists in Medicine.
引用
收藏
页码:4250 / 4259
页数:10
相关论文
共 50 条
  • [21] Comparison of Digital Breast Tomosynthesis and Digital Mammography for Detection of Breast Cancer in Kuwaiti Women
    Asbeutah, Akram M.
    Karmani, Nouralhuda
    Asbeutah, AbdulAziz A.
    Echreshzadeh, Yasmin A.
    AlMajran, Abdullah A.
    Al-Khalifah, Khalid H.
    MEDICAL PRINCIPLES AND PRACTICE, 2019, 28 (01) : 10 - 15
  • [22] Microwave Radar-Based Breast Cancer Detection: Imaging in Inhomogeneous Breast Phantoms
    Klemm, M.
    Leendertz, J. A.
    Gibbins, D.
    Craddock, I. J.
    Preece, A.
    Benjamin, R.
    IEEE ANTENNAS AND WIRELESS PROPAGATION LETTERS, 2009, 8 : 1349 - 1352
  • [23] Scanner for Integrated X-Ray Breast Tomosynthesis and Molecular Breast Imaging Tomosynthesis
    Williams, Mark B.
    Judy, Patricia G.
    Gong, Zongyi
    Graham, Audrey E.
    Majewski, Stan
    Gunn, Spencer
    DIGITAL MAMMOGRAPHY, 2010, 6136 : 444 - +
  • [24] The Preoperative Role of Breast-specific Gamma Imaging for the Breast Cancer Patients: In Comparison with Conventional Imaging Modality
    Hur, Sung Mo
    Kim, Sung Hoon
    Lee, Se Kyung
    Kim, Wan Wook
    Choi, Jae Hyuck
    Kim, Sangmin
    Lee, Su-Jin
    Choi, Jun-Young
    Choe, Jun-Ho
    Kim, Jung-Han
    Kim, Jee Soo
    Nam, Seok-Jin
    Yang, Jung-Hyun
    Lee, Jeong Eon
    JOURNAL OF BREAST CANCER, 2010, 13 (02) : 198 - 205
  • [25] The Preoperative Role of Breast-Specific Gamma Imaging for Breast Cancer Patients: A Comparison With Conventional Imaging Modalities
    Hur, Sung Mo
    Kim, Sung Hoon
    Kim, Wan Wook
    Lee, Se Kyung
    Ryu, Jae Min
    Choi, Min Young
    Nam, Seok Jin
    Yang, Jung-Hyun
    Lee, Jeong Eon
    ANNALS OF SURGICAL ONCOLOGY, 2010, 17 (02) : S175 - S175
  • [26] Overview of the evidence on digital breast tomosynthesis in breast cancer detection
    Houssami, Nehmat
    Skaane, Per
    BREAST, 2013, 22 (02): : 101 - 108
  • [27] Comparison study of reconstruction algorithms for prototype digital breast tomosynthesis using various breast phantoms
    Ye-seul Kim
    Hye-suk Park
    Haeng-Hwa Lee
    Young-Wook Choi
    Jae-Gu Choi
    Hak Hee Kim
    Hee-Joung Kim
    La radiologia medica, 2016, 121 : 81 - 92
  • [28] Comparison study of reconstruction algorithms for prototype digital breast tomosynthesis using various breast phantoms
    Kim, Ye-seul
    Park, Hye-suk
    Lee, Haeng-Hwa
    Choi, Young-Wook
    Choi, Jae-Gu
    Kim, Hak Hee
    Kim, Hee-Joung
    RADIOLOGIA MEDICA, 2016, 121 (02): : 81 - 92
  • [29] Detection of breast cancer in digital breast tomosynthesis with vision transformers
    Kassis, Idan
    Lederman, Dror
    Ben-Arie, Gal
    Rosenthal, Maia Giladi
    Shelef, Ilan
    Zigel, Yaniv
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [30] Breast-specific gamma imaging as an adjunct imaging modality for the diagnosis of breast cancer
    Brem, Rachel F.
    Floerke, Angelique C.
    Rapelyea, Jocelyn A.
    Teal, Christine
    Kelly, Tricia
    Mathur, Vivek
    RADIOLOGY, 2008, 247 (03) : 651 - 657