Comparison of breast specific gamma imaging and molecular breast tomosynthesis in breast cancer detection: Evaluation in phantoms

被引:15
|
作者
Gong, Zongyi [1 ]
Williams, Mark B. [1 ,2 ,3 ]
机构
[1] Univ Virginia, Dept Radiol & Med Imaging, Charlottesville, VA 22908 USA
[2] Univ Virginia, Dept Biomed Engn, Charlottesville, VA 22908 USA
[3] Univ Virginia, Dept Phys, Charlottesville, VA 22904 USA
关键词
breast specific gamma imaging; molecular imaging; nuclear medicine; breast; tomosynthesis; PROOF-OF-CONCEPT; HIGH-RISK; DENSITY; MODALITY; SCINTIMAMMOGRAPHY; MAMMOGRAPHY; SYSTEMS; CAMERA; WOMEN; DIAGNOSIS;
D O I
10.1118/1.4922398
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Breast specific gamma imaging or molecular breast imaging (BSGI) obtains 2D images of Tc-99m sestamibi distribution in the breast. Molecular breast tomosynthesis (MBT) maps the tracer distribution in 3D by acquiring multiple projections over a limited angular range. Here, the authors compare the performance of the two technologies in terms of spatial resolution, lesion contrast, and contrast-to-noise ratio (CNR) in phantom studies under conditions of clinically relevant sestamibi dose and imaging time. Methods: The systems tested were a Dilon 6800 and a MBT prototype developed at the University of Virginia. Both systems comprise a pixelated sodium iodide scintillator, an array of position sensitive photomultipliers, and a parallel hole collimator. The active areas and energy resolution of the systems are similar. System sensitivity, spatial resolution, lesion contrast, and CNR were measured using a Petri dish, a point source phantom, and a breast phantom containing simulated lesions at two depths, respectively. A single BSGI projection was acquired. Five MBT projections were acquired over +/- 20 degrees. For both modalities, the total scan count density was comparable to that observed for each in typical 10 min human scans following injection of 22 mCi (814 MBq) of Tc-99m-sestamibi. To assess the impact of reducing the tracer dose, the pixel counts of projection images were later binomially subsampled by a factor of 2 to give images corresponding to an injected activity of approximately 11 mCi (407 MBq). Both unprocessed (pixelated) BSGI projections and interpolated (smoothed) BSGI images displayed by default on the Dilon 6800 workstation were analyzed. Volumetric images were reconstructed from the MBT projections using a maximum likelihood expectation maximization algorithm and extracted slices were analyzed. Results: Over a depth range of 1.5-7.5 cm, BSGI spatial resolution was 5.6-11.5 mm in unprocessed projections and 5.7-12.0 mm in interpolated images. Over the same range, the in-slice MBT spatial resolution was 6.7-9.4 mm. Lesion contrast was significantly improved with MBT relative to BSGI for five out of eight lesions imaged at either the 22 mCi or the 11 mCi dose level (p < 0.05). At both dose levels, significant improvements in CNR with MBT were also found for five out of eight lesions (9.8, 7.8, 6.2 mm lesions at water depth of 1.7 cm and 9.8, 7.8 mm lesions at water depth of 4.5 cm, p < 0.05). The 6.2 and 4.9 mm lesions located at 4.5 cm below the water surface were not visible in either modality at either activity level. Conclusions: Under conditions of equal dose, imaging time and similar detectors, compared to BSGI, MBT provided higher lesion contrast, higher CNR, and spatial resolution that was less depth dependent. (C) 2015 American Association of Physicists in Medicine.
引用
收藏
页码:4250 / 4259
页数:10
相关论文
共 50 条
  • [11] Comparison of MRI and digital breast tomosynthesis in the preoperative evaluation of multifocal breast cancer
    Bhavna Batohi
    Valeria Vinci
    Clare Peacock
    Michael Michell
    Asif Iqbal
    David Evans
    Juliet Morel
    Keshthra Satchithananda
    Reema Wasan
    Rumana Rahim
    Breast Cancer Research, 17
  • [12] Detection of Breast Cancer Using Digital Breast Tomosynthesis
    Veena, M.
    Padma, M. C.
    EMERGING RESEARCH IN ELECTRONICS, COMPUTER SCIENCE AND TECHNOLOGY, ICERECT 2018, 2019, 545 : 721 - 730
  • [13] Comparison of Abbreviated Breast MRI vs Digital Breast Tomosynthesis for Breast Cancer Detection among Women with a History of Breast Cancer
    Kim, Mi Young
    Suh, Young Jin
    An, Yeong Yi
    ACADEMIC RADIOLOGY, 2022, 29 (10) : 1458 - 1465
  • [14] Breast Specific Gamma Imaging as an Adjunct Imaging Modality for the Diagnosis of Breast Cancer
    Brem, R. F.
    Floerke, A. C.
    Rapelyea, J. A.
    Teal, C.
    Kelly, T.
    Mathur, V.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05)
  • [15] Breast MRI, digital mammography and breast tomosynthesis: Comparison of three methods for early detection of breast cancer
    Roganovic, Dragana
    Djilas, Dragana
    Vujnovic, Sasa
    Pavic, Dag
    Stojanov, Dragan
    BOSNIAN JOURNAL OF BASIC MEDICAL SCIENCES, 2015, 15 (04) : 64 - 68
  • [16] Breast-Specific Gamma Imaging for the Detection of Breast Cancer in Dense Versus Nondense Breasts
    Rechtman, Lauren R.
    Lenihan, Megan J.
    Lieberman, Jennifer H.
    Teal, Christine B.
    Torrente, Jessica
    Rapelyea, Jocelyn A.
    Brem, Rachel F.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 202 (02) : 293 - 298
  • [17] Breast-Specific Gamma Imaging for the Evaluation of Patients Treated with Neoadjuvant Chemotherapy for Breast Cancer
    Teal, Christine B.
    Millien, Jeffanne
    Edwards, Claire
    Rapelyea, Jocelyn
    Torrente, Jessica
    McSwain, Anita P.
    ANNALS OF SURGICAL ONCOLOGY, 2014, 21 : 116 - 116
  • [18] Comparison of molecular breast imaging and SPECT for detection of breast lesions
    Hruska, Carrie
    Collins, Douglas
    Phillips, Stephen
    Tortorelli, Cindy
    Maxwell, Robert
    Rhodes, Deborah
    O'Connor, Michael
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [19] Comparison of Breast MR Imaging with Molecular Breast Imaging in Breast Cancer Screening, Diagnosis, Staging, and Treatment Response Evaluation
    Rauch, Gaiane M.
    Adrada, Beatriz E.
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2018, 26 (02) : 273 - +
  • [20] A COMPARISON OF DIGITAL BREAST TOMOSYNTHESIS AND FULL FIELD DIGITAL MAMMOGRAPHY IN THE DETECTION OF BREAST CANCER
    Moradzadeh, A.
    Bassett, L. W.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2013, 61 (01) : 128 - 128