Integration of fluoroscopy-based guidance in orthopaedic trauma surgery - A prospective cohort study

被引:9
|
作者
Kraus, Michael [1 ,2 ]
von dem Berge, Stephanie [3 ]
Schoell, Hendrik [4 ]
Krischak, Gert [1 ,2 ]
Gebhard, Florian [4 ]
机构
[1] Univ Ulm, Inst Res Rehabil Med, D-88422 Bad Buchau, Germany
[2] Federseeklin Bad Buchau, D-88422 Bad Buchau, Germany
[3] Univ & Rehabil Kliniken Ulm, Dept Anaesthesiol, D-89081 Ulm, Germany
[4] Univ Ulm, Dept Trauma Hand & Reconstruct Surg, D-89081 Ulm, Germany
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2013年 / 44卷 / 11期
关键词
Image-based guidance; Computer navigation; Intra-operative imaging; Fluoroscopy; Trauma; Fracture; C-arm; HIGH TIBIAL OSTEOTOMY; NAVIGATION; ANTEGRADE;
D O I
10.1016/j.injury.2013.02.008
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: Computer-assisted guidance systems are not used frequently for musculoskeletal injuries unless there are potential advantages. We investigated a novel fluoroscopy-based image guidance system in orthopaedic trauma surgery. Materials and methods: The study was a prospective, not randomised, single-centre case series at a level I trauma centre. A total of 45 patients with 46 injuries (foot 12, shoulder 10, long bones seven, hand and wrist seven, ankle seven and spine and pelvis four) were included. Different surgical procedures were examined following the basic principles of the Arbeitsgemeinschaft fur Osteosynthesefragen/Association for the Study of Internal Fixation (AO/ASIF). Main outcome measurements were the number of trials for implant placement, total surgery time, usability via user questionnaire and system failure rate. Results: In all cases, the trajectory function was used, inserting a total of 56 guided implants. The system failed when used in pelvic and spinal injuries, resulting in a total failure rate of 6.5% (n = 3) of all included cases. The overall usability was rated as good, scoring 84.3%. Conclusion: The novel image-guidance system could be integrated into the surgical workflow and was used successfully in orthopaedic trauma surgery. Expected advantages should be explored in randomised studies. (c) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1486 / 1492
页数:7
相关论文
共 50 条
  • [1] Comparison of fluoroscopy and fluoroscopy-based 2D computer navigation for iliosacral screw placement: a retrospective study
    Madeja, Roman
    Pometlova, Jana
    Osemlak, Pawel
    Voves, Jiri
    Bialy, Lubor
    Vrtkova, Adela
    Pleva, Leopold
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2022, 48 (06) : 4897 - 4902
  • [2] Orthopaedic Trauma Patients and Depression: A Prospective Cohort
    Becher, Stephen
    Smith, Michele
    Ziran, Bruce
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2014, 28 (10) : E242 - E246
  • [3] Analysing outcomes through orthopaedic trauma registry - A prospective cohort study
    Ahmad, Tashfeen
    Muhammad, Zehra Abdul
    Noordin, Shahryar
    Humayun, Ammar
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2019, 69 (01) : S7 - S11
  • [4] A new approach to computer-aided spine surgery: fluoroscopy-based surgical navigation
    L. -P. Nolte
    M. A. Slomczykowski
    U. Berlemann
    M. J. Strauss
    R. Hofstetter
    D. Schlenzka
    T. Laine
    T. Lund
    European Spine Journal, 2000, 9 : S078 - S088
  • [5] A new approach to computer-aided spine surgery: fluoroscopy-based surgical navigation
    Nolte, LP
    Slomczykowski, MA
    Berlemann, U
    Strauss, MJ
    Hofstetter, R
    Schlenzka, D
    Laine, T
    Lund, T
    EUROPEAN SPINE JOURNAL, 2000, 9 (Suppl 1) : S78 - S88
  • [6] A novel fluoroscopy-based robot system for pedicle screw fixation surgery
    Luo, Yanzhong
    Li, Zhuofu
    Jiang, Shuai
    Hu, Lei
    Liu, Wenyong
    Li, Weishi
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2020, 16 (06) : 1 - 8
  • [7] Comparison of fluoroscopy and fluoroscopy-based 2D computer navigation for iliosacral screw placement: a retrospective study
    Roman Madeja
    Jana Pometlová
    Pawel Osemlak
    Jiří Voves
    Lubor Bialy
    Adéla Vrtková
    Leopold Pleva
    European Journal of Trauma and Emergency Surgery, 2022, 48 : 4897 - 4902
  • [8] The impact of preexisting disease on outcomes of simple orthopaedic trauma: A prospective cohort study
    Rachele, Quested
    Danielle, Wiltshire
    Scott, Sommerville
    Michael, Lutz
    JOURNAL OF ORTHOPAEDICS TRAUMA AND REHABILITATION, 2019, 26 (01) : 14 - 17
  • [9] Drill-mounted video guidance for orthopaedic trauma surgery
    Vagdargi, Prasad
    Sheth, Niral
    Sisniega, Alejandro
    Uneri, Ali
    De Silva, Tharindu
    Osgood, Greg M.
    Siewerdsen, Jeffrey H.
    JOURNAL OF MEDICAL IMAGING, 2021, 8 (01)
  • [10] A fluoroscopy-based planning and guidance software tool for minimally invasive hip refixation by cement injection
    Malan, Daniel F.
    van der Walt, Stefan J.
    Raidou, Renata G.
    van den Berg, Bas
    Stoel, Berend C.
    Botha, Charl P.
    Nelissen, Rob G. H. H.
    Valstar, Edward R.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2016, 11 (02) : 281 - 296