Screening for anabolic steroids in doping analysis by liquid chromatography/electrospray ion trap mass spectrometry

被引:53
作者
Deventer, K. [1 ]
Van Eenoo, P. [1 ]
Delbeke, F. T. [1 ]
机构
[1] Univ Ghent, Dept Clin Chem Microbiol & Immunol, DoCoLab, B-9052 Zwijnaarde, Belgium
关键词
anabolic steroids; stanozolol; 3 '-hydroxystanozolol; gestrinone; 17; alpha-trenbolone; doping analysis;
D O I
10.1002/bmc.579
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A fast and selective LC/MS/MS method for the screening of four anabolic steroids in human urine has been developed and validated. Liquid-liquid extraction with diethyl ether was applied after enzymatic hydrolysis. Analyses were performed on an ion trap mass spectrometer equipped with electrospray ionisation. MS/MS was applied for all compounds. The analytical run time was 11 min. ne LOD for all compounds varied between 1 and 10 ng/mL. Left-over A samples, which were declared positive by GC/MS for the presence of 3'-hydroxystanozolol, were assessed using the described method. Copyright (c) 2005 John Wiley & Sons, Ltd.
引用
收藏
页码:429 / 433
页数:5
相关论文
共 16 条
[1]   Testing for natural and synthetic anabolic agents in human urine [J].
Ayotte, C ;
Goudreault, D ;
Charlebois, A .
JOURNAL OF CHROMATOGRAPHY B, 1996, 687 (01) :3-25
[2]   Mechanistic aspects of electrospray ionization [J].
Bruins, AP .
JOURNAL OF CHROMATOGRAPHY A, 1998, 794 (1-2) :345-357
[3]   Tetrahydrogestrinone: discovery, synthesis, and detection in urine [J].
Catlin, DH ;
Sekera, MH ;
Ahrens, BD ;
Starcevic, B ;
Chang, YC ;
Hatton, CK .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (12) :1245-1249
[4]  
Choi MH, 1999, RAPID COMMUN MASS SP, V13, P376, DOI 10.1002/(SICI)1097-0231(19990315)13:5<376::AID-RCM494>3.0.CO
[5]  
2-#
[6]  
DEVENTER K, IN PRESS J CHROMAT B
[7]  
Eurachem Working Group, 1998, LAB GUID METH VAL RE
[8]   Sensitive liquid chromatographic/tandem mass spectrometric method for the determination of beclomethasone dipropionate and its metabolites in equine plasma and urine [J].
Guan, FY ;
Uboh, C ;
Soma, L ;
Hess, A ;
Luo, Y ;
Tsang, DS .
JOURNAL OF MASS SPECTROMETRY, 2003, 38 (08) :823-838
[9]   Screening of free 17-alkyl-substituted anabolic steroids in human urine by liquid chromatography-electrospray ionization tandem mass spectrometry [J].
Leinonen, A ;
Kuuranne, T ;
Kotiaho, T ;
Kostiainen, R .
STEROIDS, 2004, 69 (02) :101-109
[10]   Liquid chromatography/mass spectrometry in anabolic steroid analysis-optimization and comparison of three ionization techniques: electrospray ionization, atmospheric pressure chemical ionization and atmospheric pressure photoionization [J].
Leinonen, A ;
Kuuranne, T ;
Kostiainen, R .
JOURNAL OF MASS SPECTROMETRY, 2002, 37 (07) :693-698