Simplified method of scatter correction using a beam-stop-array algorithm for cone-beam computed tomography breast imaging
被引:10
|
作者:
Cai, Weixing
论文数: 0引用数: 0
h-index: 0
机构:
Univ Rochester, Med Ctr, Dept Imaging Sci, Rochester, NY 14642 USA
Univ Rochester, Dept Phys Astron, Rochester, NY 14642 USAUniv Rochester, Med Ctr, Dept Imaging Sci, Rochester, NY 14642 USA
Cai, Weixing
[1
,2
]
Ning, Ruola
论文数: 0引用数: 0
h-index: 0
机构:
Univ Rochester, Med Ctr, Dept Imaging Sci, Rochester, NY 14642 USAUniv Rochester, Med Ctr, Dept Imaging Sci, Rochester, NY 14642 USA
Ning, Ruola
[1
]
Conover, David
论文数: 0引用数: 0
h-index: 0
机构:
Univ Rochester, Med Ctr, Dept Imaging Sci, Rochester, NY 14642 USAUniv Rochester, Med Ctr, Dept Imaging Sci, Rochester, NY 14642 USA
Conover, David
[1
]
机构:
[1] Univ Rochester, Med Ctr, Dept Imaging Sci, Rochester, NY 14642 USA
[2] Univ Rochester, Dept Phys Astron, Rochester, NY 14642 USA
medical imaging;
x-ray imaging;
cone-beam CT;
scatter correction;
D O I:
10.1117/1.2977527
中图分类号:
O43 [光学];
学科分类号:
070207 ;
0803 ;
摘要:
In flat-panel detector-based cone-beam computed-tomography breast imaging (CBCTBI) systems, scatter is an important factor that degrades image quality. It has been shown that despite the use of a large air gap, scatter still causes problems when imaging breast phantoms with our CBCTBI prototype. As a result, linear attenuation coefficient (LAC) distortion is obvious in the reconstruction; it appears as cupping artifacts and contrast loss. A simplified beam-stop array (BSA) algorithm is presented in this paper to solve this problem practically and efficiently. When the breast is positioned along the rotational axis, the scatter profiles from different views along a circular orbit are similar, and thus it is possible to use only one x-ray shot with the BSA in place for scatter pattern estimation, and this BSA image is used to generate a scatter pattern for all projections. The result of this scatter correction algorithm is compared with the reconstruction image over a small field of view, where scatter is assumed to be negligible, and the relative reconstruction error (RRE) is evaluated. The reconstruction is not sensitive to the estimation of scatter profile curvature, but is sensitive to the estimation of scatter intensity. It is shown as well that for any angular position where the BSA image is taken, the RRE is very small. The results show that the BSA algorithm works well for our CBCTBI prototype system with almost unchanged x-ray exposure. (C) 2008 Society of Photo-Optical Instrumentation Engineers. [DOI: 10.1117/1.2977527]
机构:
Yonsei Univ, Dept Radiol Sci, Wonju, South Korea
Yonsei Univ, Res Inst Hlth Sci, Wonju, South KoreaYonsei Univ, Dept Radiol Sci, Wonju, South Korea
Lee, Haeng-hwa
Kim, Ye-seul
论文数: 0引用数: 0
h-index: 0
机构:
Yonsei Univ, Dept Radiol Sci, Wonju, South Korea
Yonsei Univ, Res Inst Hlth Sci, Wonju, South KoreaYonsei Univ, Dept Radiol Sci, Wonju, South Korea
Kim, Ye-seul
Park, Hye-Suk
论文数: 0引用数: 0
h-index: 0
机构:
Yonsei Univ, Dept Radiol Sci, Wonju, South Korea
Yonsei Univ, Res Inst Hlth Sci, Wonju, South KoreaYonsei Univ, Dept Radiol Sci, Wonju, South Korea
Park, Hye-Suk
Kim, Hee-Joung
论文数: 0引用数: 0
h-index: 0
机构:
Yonsei Univ, Dept Radiol Sci, Wonju, South Korea
Yonsei Univ, Res Inst Hlth Sci, Wonju, South KoreaYonsei Univ, Dept Radiol Sci, Wonju, South Korea
Kim, Hee-Joung
Choi, Jae-Gu
论文数: 0引用数: 0
h-index: 0
机构:
Korea Electrotechnol Res Inst, Ansan, South KoreaYonsei Univ, Dept Radiol Sci, Wonju, South Korea
Choi, Jae-Gu
Choi, Young-Wook
论文数: 0引用数: 0
h-index: 0
机构:
Korea Electrotechnol Res Inst, Ansan, South KoreaYonsei Univ, Dept Radiol Sci, Wonju, South Korea
Choi, Young-Wook
MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING,
2014,
9033
机构:
Key Laboratory of Contemporary Design and Integrated Manufacturing Technology of the Ministry of Education,Northwestern Polytechnical UniversityKey Laboratory of Contemporary Design and Integrated Manufacturing Technology of the Ministry of Education,Northwestern Polytechnical University