Simplified method of scatter correction using a beam-stop-array algorithm for cone-beam computed tomography breast imaging

被引:10
|
作者
Cai, Weixing [1 ,2 ]
Ning, Ruola [1 ]
Conover, David [1 ]
机构
[1] Univ Rochester, Med Ctr, Dept Imaging Sci, Rochester, NY 14642 USA
[2] Univ Rochester, Dept Phys Astron, Rochester, NY 14642 USA
关键词
medical imaging; x-ray imaging; cone-beam CT; scatter correction;
D O I
10.1117/1.2977527
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In flat-panel detector-based cone-beam computed-tomography breast imaging (CBCTBI) systems, scatter is an important factor that degrades image quality. It has been shown that despite the use of a large air gap, scatter still causes problems when imaging breast phantoms with our CBCTBI prototype. As a result, linear attenuation coefficient (LAC) distortion is obvious in the reconstruction; it appears as cupping artifacts and contrast loss. A simplified beam-stop array (BSA) algorithm is presented in this paper to solve this problem practically and efficiently. When the breast is positioned along the rotational axis, the scatter profiles from different views along a circular orbit are similar, and thus it is possible to use only one x-ray shot with the BSA in place for scatter pattern estimation, and this BSA image is used to generate a scatter pattern for all projections. The result of this scatter correction algorithm is compared with the reconstruction image over a small field of view, where scatter is assumed to be negligible, and the relative reconstruction error (RRE) is evaluated. The reconstruction is not sensitive to the estimation of scatter profile curvature, but is sensitive to the estimation of scatter intensity. It is shown as well that for any angular position where the BSA image is taken, the RRE is very small. The results show that the BSA algorithm works well for our CBCTBI prototype system with almost unchanged x-ray exposure. (C) 2008 Society of Photo-Optical Instrumentation Engineers. [DOI: 10.1117/1.2977527]
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Limited cone-beam computed tomography imaging of the middle ear: A comparison with multislice helical computed tomography
    Peltonen, L. I.
    Aarnisalo, A. A.
    Kortesniemi, M. K.
    Suomalainen, A.
    Jero, J.
    Robinson, S.
    ACTA RADIOLOGICA, 2007, 48 (02) : 207 - 212
  • [42] Mandible Bone Osteoporosis Detection using Cone-beam Computed Tomography
    Abu Marar, Rasha F.
    Uliyan, Diaa M.
    Al-Sewadi, Hamza A.
    ENGINEERING TECHNOLOGY & APPLIED SCIENCE RESEARCH, 2020, 10 (04) : 6027 - 6033
  • [43] PREDOCTORAL AND POSTDOCTORAL EDUCATION ON CONE-BEAM COMPUTED TOMOGRAPHY
    Buchanan, Allison
    Thachil, Karan
    Haggard, Chris
    Kalathingal, Sajitha
    JOURNAL OF EVIDENCE-BASED DENTAL PRACTICE, 2017, 17 (04) : 310 - 316
  • [44] The beam stop array method to measure object scatter in digital breast tomosynthesis
    Lee, Haeng-hwa
    Kim, Ye-seul
    Park, Hye-Suk
    Kim, Hee-Joung
    Choi, Jae-Gu
    Choi, Young-Wook
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [45] Quality Control in Dental Cone-Beam Computed Tomography
    Huang, Jin-Feng
    Chen, Xiao-Zhao
    Wang, Hong
    APPLIED SCIENCES-BASEL, 2021, 11 (17):
  • [46] Scatter correction method for cone-beam CT based on interlacing-slit scan
    黄魁东
    张华
    史仪凯
    张亮
    徐哲
    Chinese Physics B, 2014, (09) : 519 - 525
  • [47] Scatter measurement and correction method for cone-beam CT based on single grating scan
    Huang, Kuidong
    Shi, Wenlong
    Wang, Xinyu
    Dong, Yin
    Chang, Taoqi
    Zhang, Hua
    Zhang, Dinghua
    OPTICAL ENGINEERING, 2017, 56 (06)
  • [48] Scatter correction in cone-beam CT via a half beam blocker technique allowing simultaneous acquisition of scatter and image information
    Lee, Ho
    Xing, Lei
    Lee, Rena
    Fahimian, Benjamin P.
    MEDICAL PHYSICS, 2012, 39 (05) : 2386 - 2395
  • [49] Scatter correction method for cone-beam CT based on interlacing-slit scan
    Huang Kui-Dong
    Zhang Hua
    Shi Yi-Kai
    Zhang Liang
    Xu Zhe
    CHINESE PHYSICS B, 2014, 23 (09)
  • [50] Dose and Image Quality of Cone-Beam Computed Tomography as Compared With Conventional Multislice Computed Tomography in Abdominal Imaging
    Schegerer, Alexander A.
    Lechel, Ursula
    Ritter, Manuel
    Weisser, Gerald
    Fink, Christian
    Brix, Gunnar
    INVESTIGATIVE RADIOLOGY, 2014, 49 (10) : 675 - 684