Simplified method of scatter correction using a beam-stop-array algorithm for cone-beam computed tomography breast imaging

被引:10
|
作者
Cai, Weixing [1 ,2 ]
Ning, Ruola [1 ]
Conover, David [1 ]
机构
[1] Univ Rochester, Med Ctr, Dept Imaging Sci, Rochester, NY 14642 USA
[2] Univ Rochester, Dept Phys Astron, Rochester, NY 14642 USA
关键词
medical imaging; x-ray imaging; cone-beam CT; scatter correction;
D O I
10.1117/1.2977527
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In flat-panel detector-based cone-beam computed-tomography breast imaging (CBCTBI) systems, scatter is an important factor that degrades image quality. It has been shown that despite the use of a large air gap, scatter still causes problems when imaging breast phantoms with our CBCTBI prototype. As a result, linear attenuation coefficient (LAC) distortion is obvious in the reconstruction; it appears as cupping artifacts and contrast loss. A simplified beam-stop array (BSA) algorithm is presented in this paper to solve this problem practically and efficiently. When the breast is positioned along the rotational axis, the scatter profiles from different views along a circular orbit are similar, and thus it is possible to use only one x-ray shot with the BSA in place for scatter pattern estimation, and this BSA image is used to generate a scatter pattern for all projections. The result of this scatter correction algorithm is compared with the reconstruction image over a small field of view, where scatter is assumed to be negligible, and the relative reconstruction error (RRE) is evaluated. The reconstruction is not sensitive to the estimation of scatter profile curvature, but is sensitive to the estimation of scatter intensity. It is shown as well that for any angular position where the BSA image is taken, the RRE is very small. The results show that the BSA algorithm works well for our CBCTBI prototype system with almost unchanged x-ray exposure. (C) 2008 Society of Photo-Optical Instrumentation Engineers. [DOI: 10.1117/1.2977527]
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Use of cone-beam computed tomography for advanced imaging of the equine patient
    Stewart, Holly L.
    Siewerdsen, Jeffery H.
    Nelson, Brad B.
    Kawcak, Christopher E.
    EQUINE VETERINARY JOURNAL, 2021, 53 (05) : 872 - 885
  • [32] Single-scan scatter correction for cone-beam CT using a stationary beam blocker: a preliminary study
    Niu, Tianye
    Zhu, Lei
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [33] Scatter Correction Method for Cone Beam CT Using Beam Attenuation Grid
    Xie, Shipeng
    Luo, Limin
    Yang, Lifeng
    Zhang, Feng
    MATERIALS ENGINEERING FOR ADVANCED TECHNOLOGIES, PTS 1 AND 2, 2011, 480-481 : 341 - +
  • [34] Local filtration based scatter correction for cone-beam CT using primary modulation
    Zhu, Lei
    MEDICAL PHYSICS, 2016, 43 (11) : 6199 - 6209
  • [35] Scatter correction for clinical cone beam CT breast imaging based on breast phantom studies
    Cai, Weixing
    Ning, Ruola
    Conover, David
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2011, 19 (01) : 91 - 109
  • [36] Robust scatter correction method for cone-beam CT using an interlacing-slit plate
    Huang, Kui-Dong
    Xu, Zhe
    Zhang, Ding-Hua
    Zhang, Hua
    Shi, Wen-Long
    CHINESE PHYSICS C, 2016, 40 (06) : 99 - 106
  • [37] A calibration method for misaligned scanner geometry in cone-beam computed tomography
    Sun, Yi
    Hou, Ying
    Zhao, Fengyong
    Hu, Jiasheng
    NDT & E INTERNATIONAL, 2006, 39 (06) : 499 - 513
  • [38] 4D cone-beam computed tomography (CBCT) using a moving blocker for simultaneous radiation dose reduction and scatter correction
    Zhao, Cong
    Zhong, Yuncheng
    Duan, Xinhui
    Zhang, You
    Huang, Xiaokun
    Wang, Jing
    Jin, Mingwu
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (11)
  • [39] Unpaired-Paired Learning for Shading Correction in Cone-Beam Computed Tomography
    Park, Hyoung Suk
    Jeon, Kiwan
    Lee, Sang-Hwy
    Seo, Jin Keun
    IEEE ACCESS, 2022, 10 : 26140 - 26148
  • [40] A rotating beam-blocker method for cone beam CT scatter correction
    Cui, Hehe
    Zhan, Haolin
    Yuan, Xiaogang
    Yang, Yidong
    MEDICAL PHYSICS, 2024, 51 (10) : 7320 - 7331