Simplified method of scatter correction using a beam-stop-array algorithm for cone-beam computed tomography breast imaging

被引:10
|
作者
Cai, Weixing [1 ,2 ]
Ning, Ruola [1 ]
Conover, David [1 ]
机构
[1] Univ Rochester, Med Ctr, Dept Imaging Sci, Rochester, NY 14642 USA
[2] Univ Rochester, Dept Phys Astron, Rochester, NY 14642 USA
关键词
medical imaging; x-ray imaging; cone-beam CT; scatter correction;
D O I
10.1117/1.2977527
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In flat-panel detector-based cone-beam computed-tomography breast imaging (CBCTBI) systems, scatter is an important factor that degrades image quality. It has been shown that despite the use of a large air gap, scatter still causes problems when imaging breast phantoms with our CBCTBI prototype. As a result, linear attenuation coefficient (LAC) distortion is obvious in the reconstruction; it appears as cupping artifacts and contrast loss. A simplified beam-stop array (BSA) algorithm is presented in this paper to solve this problem practically and efficiently. When the breast is positioned along the rotational axis, the scatter profiles from different views along a circular orbit are similar, and thus it is possible to use only one x-ray shot with the BSA in place for scatter pattern estimation, and this BSA image is used to generate a scatter pattern for all projections. The result of this scatter correction algorithm is compared with the reconstruction image over a small field of view, where scatter is assumed to be negligible, and the relative reconstruction error (RRE) is evaluated. The reconstruction is not sensitive to the estimation of scatter profile curvature, but is sensitive to the estimation of scatter intensity. It is shown as well that for any angular position where the BSA image is taken, the RRE is very small. The results show that the BSA algorithm works well for our CBCTBI prototype system with almost unchanged x-ray exposure. (C) 2008 Society of Photo-Optical Instrumentation Engineers. [DOI: 10.1117/1.2977527]
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Scatter Correction Based on Beam Stop Array for Cone-Beam Micro-Computed Tomography
    Tang Tianxu
    Duan Xiaojiao
    Zhou Zhizheng
    Wu Qi
    ACTA OPTICA SINICA, 2019, 39 (08)
  • [2] Scatter correction using beam stop array algorithm for cone-beam CT breast imaging - art. no. 61423E
    Cai, Weixing
    Ning, Ruola
    Conover, David
    Medical Imaging 2006: Physics of Medical Imaging, Pts 1-3, 2006, 6142 : E1423 - E1423
  • [3] An experimental study of the scatter correction by using a beam-stop-array algorithm with digital breast tomosynthesis
    Kim, Ye-Seul
    Park, Hye-Suk
    Kim, Hee-Joung
    Choi, Young-Wook
    Choi, Jae-Gu
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 65 (12) : 2117 - 2125
  • [4] An experimental study of the scatter correction by using a beam-stop-array algorithm with digital breast tomosynthesis
    Ye-seul Kim
    Hye-Suk Park
    Hee-Joung Kim
    Young-Wook Choi
    Jae-Gu Choi
    Journal of the Korean Physical Society, 2014, 65 : 2117 - 2125
  • [5] Scatter characterization using a beam-stop-array algorithm for digital breast tomosynthesis
    Choi, Young-Wook
    Choi, Jae-Gu
    Kim, Ye-seul
    Park, Hye-Suk
    Kim, Hee-Joung
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2013, 63 (11) : 2239 - 2246
  • [6] Scatter characterization using a beam-stop-array algorithm for digital breast tomosynthesis
    Young-Wook Choi
    Jae-Gu Choi
    Ye-seul Kim
    Hye-Suk Park
    Hee-Joung Kim
    Journal of the Korean Physical Society, 2013, 63 : 2239 - 2246
  • [7] Scatter correction for cone-beam computed tomography using moving blocker strips
    Wang, Jing
    Mao, Weihua
    Solberg, Timothy
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [8] Model based scatter correction for cone-beam computed tomography
    Wiegert, J
    Bertram, M
    Rose, G
    Aach, T
    MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2005, 5745 : 271 - 282
  • [9] A moving blocker system for cone-beam computed tomography scatter correction
    Ouyang, Luo
    Song, Kwang
    Wang, Jing
    MEDICAL PHYSICS, 2013, 40 (07)
  • [10] A moving blocker system for cone-beam computed tomography scatter correction
    Ouyang, Luo
    Song, Kwang
    Solberg, Timothy
    Wang, Jing
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668