Computed tomography scanogram compared to long leg radiograph for determining axial knee alignment

被引:45
作者
Holme, Thomas J. [1 ]
Henckel, Johann [1 ]
Hartshorn, Kai [1 ]
Cobb, Justin P. [2 ]
Hart, Alister J. [1 ]
机构
[1] UCL, Dept Trauma & Orthopaed, London WC1E 6BT, England
[2] Univ London Imperial Coll Sci Technol & Med, Dept Trauma & Orthopaed, London SW7 2AZ, England
关键词
ARTHROPLASTY; NAVIGATION; SUPINE;
D O I
10.3109/17453674.2014.1003488
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background and purpose - Supine computed tomography scanogram (CTS) is a commonly used alternative to weight bearing long leg plain radiograph (LLR) in measuring knee alignment. No published studies have validated its use in the native knee and the post-unicompartmental replacement knee (UKR). We quantified the difference in measurements obtained from CTS and LLR for knee alignment. Patients and methods - Supine CT scanograms and weight bearing long leg plain anteroposterior radiographs were obtained for 40 knees (in 25 patients), 17 of which were native, and 23 of which were post-UKR. The mechanical and anatomical axes of the tibio-femoral joint were measured. Bland-Altman plots were used to calculate the 1.96 standard deviation limits of agreement between CTS and LLR. Intraclass correlation was used to assess intra-rater and inter-rater reliability (where values > 0.81 indicate very good reliability). Results - CTS and LLR were equally reliable in measurement of the mechanical and anatomical axes of the tibio-femoral joint (intraclass correlation coefficient (ICC) > 0.9 for all parameters). Statistically significant and clinically relevant differences were found between CTS and LLR in measurement of the mechanical axis (limits of agreement: UKR -3.2 degrees to 6.3 degrees; native -3.2 degrees to 5.6 degrees) and the anatomical axis (limits of agreement: UKR -3.7 degrees to 8.7 degrees; native -2.0 degrees to 8.8 degrees). Interpretation - Although it is a reliable tool, CTS is not necessarily an accurate one for measurement of knee alignment when compared to LLR. We recommend that CTS should not be used as a substitute for LLR in measurement of the mechanical or anatomical axes of the knee.
引用
收藏
页码:440 / 443
页数:4
相关论文
共 18 条
[1]   The long leg radiograph is a reliable method of assessing alignment when compared to computer-assisted navigation and computer tomography [J].
Babazadeh, Sina ;
Dowsey, Michelle M. ;
Bingham, Roger J. ;
Ek, Eugene T. ;
Stoney, James D. ;
Choong, Peter F. M. .
KNEE, 2013, 20 (04) :242-249
[2]   Alignment in total knee arthroplasty -: A comparison of computer-assisted surgery with the conventional technique [J].
Bäthis, H ;
Perlick, L ;
Tingart, M ;
Lüring, C ;
Zurakowski, D ;
Grifka, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (05) :682-687
[3]   The whole leg radiograph - Standing versus supine for determining axial alignment [J].
Brouwer, RW ;
Jakma, TSC ;
Bierma-Zeinstra, SMA ;
Ginai, AZ ;
Verhaar, JAN .
ACTA ORTHOPAEDICA SCANDINAVICA, 2003, 74 (05) :565-568
[4]   Accuracy of Implant Placement Utilizing Customized Patient Instrumentation in Total Knee Arthroplasty [J].
Bugbee, William D. ;
Mizu-uchi, Hideki ;
Patil, Shantanu ;
D'Lima, Darryl .
ADVANCES IN ORTHOPEDICS, 2013, 2013
[5]   The radiological outcomes of patient-specific instrumentation versus conventional total knee arthroplasty [J].
Chen, Jerry Yongqiang ;
Yeo, Seng Jin ;
Yew, Andy Khye Soon ;
Tay, Darren Keng Jin ;
Chia, Shi-Lu ;
Lo, Ngai Nung ;
Chin, Pak Lin .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (03) :630-635
[6]   Hands-on robotic unicompartmental knee replacement - A prospective, randomised controlled study of the Acrobot system [J].
Cobb, J ;
Henckel, J ;
Gomes, P ;
Harris, S ;
Jakopec, M ;
Rodriguez y Baena, F ;
Barrett, A ;
Davies, B .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (02) :188-197
[7]   Do long leg supine CT scanograms correlate with weight-bearing full-length radiographs to measure lower limb coronal alignment? [J].
Gbejuade, H. O. ;
White, P. ;
Hassaballa, M. ;
Porteous, A. J. ;
Robinson, J. R. ;
Murray, J. R. .
KNEE, 2014, 21 (02) :549-552
[8]   The effect of leg alignment on the outcome of unicompartmental knee replacement [J].
Gulati, A. ;
Pandit, H. ;
Jenkins, C. ;
Chau, R. ;
Dodd, C. A. F. ;
Murray, D. W. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2009, 91B (04) :469-474
[9]   Predisposing factors which are relevant for the clinical outcome after revision total knee arthroplasty [J].
Hardeman, Francois ;
Londers, Jurgen ;
Favril, Alexander ;
Witvrouw, Erik ;
Bellemans, Johan ;
Victor, Jan .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2012, 20 (06) :1049-1056
[10]   Alignment influences wear in the knee after medial unicompartmental arthroplasty [J].
Hernigou, P ;
Deschamps, G .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (423) :161-165