Flow-through photochemically induced fluorescence optosensor for the determination of linuron

被引:28
作者
Piccirilli, Gisela N. [1 ]
Escandar, Graciela M. [1 ]
Canada Canada, Florentina [2 ]
Duran Meras, Isabel [2 ]
Munoz de la Pena, Arsenio [2 ]
机构
[1] Univ Nacl Rosario, Fac Ciencias Bioquim & Farmaceut, CONICET, Dept Quim Analit,Inst Quim Rosario, RA-2000 Rosario, Santa Fe, Argentina
[2] Univ Extremadura, Fac Ciencias, Dept Quim Analit, E-06071 Badajoz, Spain
关键词
Pesticides; Linuron; Photochemically induced fluorescence; Flow-through sensor; Environmental waters;
D O I
10.1016/j.talanta.2008.07.052
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This manuscript presents the development of a new photochemically induced fluorescence flow-injection system, combined with solid-surface adsorption, for the determination of the benzoylurea pesticide linuron. The determination is carried Out by measuring the fluorescence intensity of a photoproduct, formed by on-line irradiation with ultraviolet light, and retention on a solid matrix filling the flow-cell. The procedure is developed in the presence of two surfactants: sodium dodecyl sulphate and hexadecyltrimethylammonium chloride, which are critical for the detection of the fluorescence emission in the solid Surface. The possible interactions between the linuron photoproduct, the micellar medium employed and the solid Support (C-18 silica gel) are discussed. Parameters related to the analytical signal and to the FIA manifold are optimized. Finally, the feasibility of the developed method was tested by the determination of linuron in both environmental and drinking water samples. Determinations at mu g L-1 level were accomplished after a solid-phase pre-concentration procedure. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:852 / 857
页数:6
相关论文
共 47 条
[1]  
Barroso MB, 1999, HRC-J HIGH RES CHROM, V22, P171, DOI [10.1002/(SICI)1521-4168(19990301)22:3<171::AID-JHRC171>3.0.CO
[2]  
2-Z, 10.1002/(SICI)1521-4168(19990301)22:3&lt
[3]  
171::AID-JHRC171&gt
[4]  
3.0.CO
[5]  
2-Z]
[6]   Usefulness of micellar media for the quantitative analysis of phenylurea herbicides in water by photochemically-induced fluorescence [J].
Bautista, A ;
Aaron, JJ ;
Mahedero, MC ;
de la Peña, AM .
ANALUSIS, 1999, 27 (10) :857-863
[7]   Gas chromatographic behaviour of urea herbicides [J].
Berrada, H ;
Moltó, JC ;
Font, G .
CHROMATOGRAPHIA, 2001, 54 (5-6) :360-364
[8]   Influence of the solvent on the gas chromatographic behaviour of urea herbicides [J].
Berrada, H ;
Font, G ;
Moltó, JC .
CHROMATOGRAPHIA, 2001, 54 (3-4) :253-262
[9]   DETERMINATION OF ACIDIC AND BASIC NEUTRAL PESTICIDES IN WATER WITH A NEW MICROLITER FLOW-RATE LC/MS PARTICLE-BEAM INTERFACE [J].
CAPPIELLO, A ;
FAMIGLINI, G ;
BRUNER, F .
ANALYTICAL CHEMISTRY, 1994, 66 (09) :1416-1423
[10]  
Caux PY, 1998, ENVIRON TOXIC WATER, V13, P1, DOI 10.1002/(SICI)1098-2256(1998)13:1<1::AID-TOX1>3.0.CO