B0 and B1 inhomogeneities in the liver at 1.5 T and 3.0 T

被引:27
|
作者
Roberts, Nathan T. [1 ,2 ]
Hinshaw, Louis A. [1 ]
Colgan, Timothy J. [1 ]
Ii, Takanori [1 ,3 ]
Hernando, Diego [1 ,4 ]
Reeder, Scott B. [1 ,4 ,5 ,6 ,7 ]
机构
[1] Univ Wisconsin Madison, Dept Radiol, 1111 Highland Ave,WIMR2,Room 2472, Madison, WI 53705 USA
[2] Univ Wisconsin Madison, Dept Elect & Comp Engn, Madison, WI USA
[3] Univ Yamanashi, Dept Radiol, Yamanashi, Japan
[4] Univ Wisconsin Madison, Dept Med Phys, Madison, WI USA
[5] Univ Wisconsin Madison, Dept Biomed Engn, Madison, WI USA
[6] Univ Wisconsin Madison, Dept Med, Madison, WI USA
[7] Univ Wisconsin Madison, Dept Emergency Med, Madison, WI USA
基金
美国国家卫生研究院;
关键词
B-0; B-1; dielectric effect; inhomogeneities; liver; quantitative imaging biomarkers; MAGNETIC-RESONANCE; FIELD INHOMOGENEITY; FAT; WATER; T-1; QUANTIFICATION; SEPARATION; MRI; DECOMPOSITION; DISTORTION;
D O I
10.1002/mrm.28549
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The purpose of this work is to characterize the magnitude and variability of B-0 and B-1 inhomogeneities in the liver in large cohorts of patients at both 1.5 T and 3.0 T. Methods Volumetric B-0 and B-1 maps were acquired over the liver of patients presenting for routine abdominal MRI. Regions of interest were drawn in the nine Couinaud segments of the liver, and the average value was recorded. Magnitude and variation of measured averages in each segment were reported across all patients. Results A total of 316 B-0 maps and 314 B-1 maps, acquired at 1.5 T and 3.0 T on a variety of GE Healthcare MRI systems in 630 unique exams, were identified, analyzed, and, in the interest of reproducible research, de-identified and made public. Measured B-0 inhomogeneities ranged (5th-95th percentiles) from -31.7 Hz to 164.0 Hz for 3.0 T (-14.5 Hz to 81.3 Hz at 1.5 T), while measured B-1 inhomogeneities (ratio of actual over prescribed flip angle) ranged from 0.59 to 1.13 for 3.0 T (0.83 to 1.11 at 1.5 T). Conclusion This study provides robust characterization of B-0 and B-1 inhomogeneities in the liver to guide the development of imaging applications and protocols. Field strength, bore diameter, and sex were determined to be statistically significant effects for both B-0 and B-1 uniformity. Typical clinical liver imaging at 3.0 T should expect B-0 inhomogeneities ranging from approximately -100 Hz to 250 Hz (-50 Hz to 150 Hz at 1.5 T) and B-1 inhomogeneities ranging from approximately 0.4 to 1.3 (0.7 to 1.2 at 1.5 T).
引用
收藏
页码:2212 / 2220
页数:9
相关论文
共 50 条
  • [31] High-resolution MR spectroscopy via intermolecular double-quantum coherences in inhomogeneous B0 and B1 fields
    Lin, Yanqin
    Cai, Congbo
    Cai, Shuhui
    Zhong, Jianhui
    Chen, Zhong
    MAGNETIC RESONANCE IMAGING, 2011, 29 (05) : 601 - 607
  • [32] Magnetic resonance fingerprinting of the pancreas at 1.5 T and 3.0 T
    Serrao, Eva M.
    Kessler, Dimitri A.
    Carmo, Bruno
    Beer, Lucian
    Brindle, Kevin M.
    Buonincontri, Guido
    Gallagher, Ferdia A.
    Gilbert, Fiona J.
    Godfrey, Edmund
    Graves, Martin J.
    McLean, Mary A.
    Sala, Evis
    Schulte, Rolf F.
    Kaggie, Joshua D.
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [33] DeepControl: 2DRF pulses facilitating B1+inhomogeneity and B0 off-resonance compensation in vivo at 7 T
    Vinding, Mads Sloth
    Aigner, Christoph Stefan
    Schmitter, Sebastian
    Lund, Torben Ellegaard
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (06) : 3308 - 3317
  • [34] Magnetic susceptibility as a B0 field strength independent MRI biomarker of liver iron overload
    Hernando, Diego
    Cook, Rachel J.
    Diamond, Carol
    Reeder, Scott B.
    MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (03) : 648 - 656
  • [35] The comparison of diffusion tensor imaging in human hearts between 1.5 T and 3.0 T
    Li, Xiaodan
    Chen, Rui
    Xu, Xi
    Xiao, Zebin
    Wei, Xiaoyu
    Yang, Yuelong
    Zhang, Zhongping
    Wu, Zhigang
    Zhu, Yanjie
    Liu, Hui
    BMC MEDICAL IMAGING, 2023, 23 (01)
  • [36] Estimation of geometrically undistorted B0 inhomogeneity maps
    Matakos, A.
    Balter, J.
    Cao, Y.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (17) : 4945 - 4959
  • [37] SENSE Shimming (SSH): A Fast Approach for Determining B0 Field Inhomogeneities Using Sensitivity Coding
    Splitthoff, D. N.
    Zaitsev, M.
    MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (05) : 1319 - 1325
  • [38] Quantification of T1ρ relaxation by using rotary echo spin-lock pulses in the presence of B0 inhomogeneity
    Yuan, Jing
    Li, Yujia
    Zhao, Feng
    Chan, Queenie
    Ahuja, Anil T.
    Wang, Yi-Xiang J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (15) : 5003 - 5016
  • [39] Intra-individual comparison of image contrast in SPIO-enhanced liver MRI at 1.5T and 3.0T
    Marcus von Falkenhausen
    Carsten Meyer
    Götz Lutterbey
    Nuschin Morakkabati
    Oliver Walter
    Jürgen Gieseke
    Renate Blömer
    Winfried A. Willinek
    Christiane K. Kuhl
    Hans H. Schild
    European Radiology, 2007, 17 : 1256 - 1261
  • [40] Intra-individual comparison of image contrast in SPIO-enhanced liver MRI at 1.5T and 3.0T
    von Falkenhausen, Marcus
    Meyer, Carsten
    Lutterbey, Goetz
    Morakkabati, Nuschin
    Walter, Oliver
    Gieseke, Juergen
    Bloemer, Renate
    Willinek, Winfried A.
    Kuhl, Christiane K.
    Schild, Hans H.
    EUROPEAN RADIOLOGY, 2007, 17 (05) : 1256 - 1261