B0 and B1 inhomogeneities in the liver at 1.5 T and 3.0 T

被引:27
|
作者
Roberts, Nathan T. [1 ,2 ]
Hinshaw, Louis A. [1 ]
Colgan, Timothy J. [1 ]
Ii, Takanori [1 ,3 ]
Hernando, Diego [1 ,4 ]
Reeder, Scott B. [1 ,4 ,5 ,6 ,7 ]
机构
[1] Univ Wisconsin Madison, Dept Radiol, 1111 Highland Ave,WIMR2,Room 2472, Madison, WI 53705 USA
[2] Univ Wisconsin Madison, Dept Elect & Comp Engn, Madison, WI USA
[3] Univ Yamanashi, Dept Radiol, Yamanashi, Japan
[4] Univ Wisconsin Madison, Dept Med Phys, Madison, WI USA
[5] Univ Wisconsin Madison, Dept Biomed Engn, Madison, WI USA
[6] Univ Wisconsin Madison, Dept Med, Madison, WI USA
[7] Univ Wisconsin Madison, Dept Emergency Med, Madison, WI USA
基金
美国国家卫生研究院;
关键词
B-0; B-1; dielectric effect; inhomogeneities; liver; quantitative imaging biomarkers; MAGNETIC-RESONANCE; FIELD INHOMOGENEITY; FAT; WATER; T-1; QUANTIFICATION; SEPARATION; MRI; DECOMPOSITION; DISTORTION;
D O I
10.1002/mrm.28549
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The purpose of this work is to characterize the magnitude and variability of B-0 and B-1 inhomogeneities in the liver in large cohorts of patients at both 1.5 T and 3.0 T. Methods Volumetric B-0 and B-1 maps were acquired over the liver of patients presenting for routine abdominal MRI. Regions of interest were drawn in the nine Couinaud segments of the liver, and the average value was recorded. Magnitude and variation of measured averages in each segment were reported across all patients. Results A total of 316 B-0 maps and 314 B-1 maps, acquired at 1.5 T and 3.0 T on a variety of GE Healthcare MRI systems in 630 unique exams, were identified, analyzed, and, in the interest of reproducible research, de-identified and made public. Measured B-0 inhomogeneities ranged (5th-95th percentiles) from -31.7 Hz to 164.0 Hz for 3.0 T (-14.5 Hz to 81.3 Hz at 1.5 T), while measured B-1 inhomogeneities (ratio of actual over prescribed flip angle) ranged from 0.59 to 1.13 for 3.0 T (0.83 to 1.11 at 1.5 T). Conclusion This study provides robust characterization of B-0 and B-1 inhomogeneities in the liver to guide the development of imaging applications and protocols. Field strength, bore diameter, and sex were determined to be statistically significant effects for both B-0 and B-1 uniformity. Typical clinical liver imaging at 3.0 T should expect B-0 inhomogeneities ranging from approximately -100 Hz to 250 Hz (-50 Hz to 150 Hz at 1.5 T) and B-1 inhomogeneities ranging from approximately 0.4 to 1.3 (0.7 to 1.2 at 1.5 T).
引用
收藏
页码:2212 / 2220
页数:9
相关论文
共 50 条
  • [1] A novel spectrally selective fat saturation pulse design with robustness to B0 and B1 inhomogeneities: A demonstration on 3D T1-weighted breast MRI at 3 T
    Xu, Feng
    Li, Wenbo
    Liu, Dapeng
    Zhu, Dan
    Schaer, Michael
    Myers, Kelly
    Qin, Qin
    MAGNETIC RESONANCE IMAGING, 2021, 75 : 156 - 161
  • [2] Correction of errors in estimates of T1ρ at low spin-lock amplitudes in the presence of B0 and B1 inhomogeneities
    Zu, Zhongliang
    Adelnia, Fatemeh
    Harkins, Kevin
    Wang, Feng
    Ostenson, Jason
    Gore, John C.
    NMR IN BIOMEDICINE, 2023, 36 (09)
  • [3] On-resonance and off-resonance continuous wave constant amplitude spin-lock and T1 quantification in the presence of B1 and B0 inhomogeneities
    Jiang, Baiyan
    Chen, Weitian
    NMR IN BIOMEDICINE, 2018, 31 (07)
  • [4] Quantitative T1ρ imaging using phase cycling for B0 and B1 field inhomogeneity compensation
    Chen, Weitian
    Takahashi, Atsushi
    Han, Eric
    MAGNETIC RESONANCE IMAGING, 2011, 29 (05) : 608 - 619
  • [5] A novel method for T2 quantification in presence of B1 inhomogeneities
    Milford, David
    Bendszus, Martin
    Heiland, Sabine
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2018, 28 (01): : 63 - 72
  • [6] Multislice 1H MRSI of the human brain at 7 T using dynamic B0 and B1 shimming
    Boer, Vincent O.
    Klomp, Dennis W. J.
    Juchem, Christoph
    Luijten, Peter R.
    de Graaf, Robin A.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (03) : 662 - 670
  • [7] Metal artifacts of hip arthroplasty implants at 1.5-T and 3.0-T: a closer look into the B1 effects
    Iman Khodarahmi
    John Kirsch
    Gregory Chang
    Jan Fritz
    Skeletal Radiology, 2021, 50 : 1007 - 1015
  • [8] Mapping tissue water T1 in the liver using the MOLLI T1 method in the presence of fat, iron and B0 inhomogeneity
    Mozes, Ferenc E.
    Tunnicliffe, Elizabeth M.
    Moolla, Ahmad
    Marjot, Thomas
    Levick, Christina K.
    Pavlides, Michael
    Robson, Matthew D.
    NMR IN BIOMEDICINE, 2019, 32 (02)
  • [9] Frequency Offset Corrected Inversion Pulse for B0 and B1 Insensitive Fat Suppression at 3T: Application to MR Neurography of Brachial Plexus
    Wang, Xinzeng
    Greer, Joshua S.
    Dimitrov, Ivan E.
    Pezeshk, Parham
    Chhabra, Avneesh
    Madhuranthakam, Ananth J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2018, 48 (04) : 1104 - 1111
  • [10] Shimming toolbox: An open-source software toolbox for B0 and B1 shimming in MRI
    D'Astous, Alexandre
    Cereza, Gaspard
    Papp, Daniel
    Gilbert, Kyle M.
    Stockmann, Jason P.
    Alonso-Ortiz, Eva
    Cohen-Adad, Julien
    MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (04) : 1401 - 1417