B0 and B1 inhomogeneities in the liver at 1.5 T and 3.0 T

被引:28
作者
Roberts, Nathan T. [1 ,2 ]
Hinshaw, Louis A. [1 ]
Colgan, Timothy J. [1 ]
Ii, Takanori [1 ,3 ]
Hernando, Diego [1 ,4 ]
Reeder, Scott B. [1 ,4 ,5 ,6 ,7 ]
机构
[1] Univ Wisconsin Madison, Dept Radiol, 1111 Highland Ave,WIMR2,Room 2472, Madison, WI 53705 USA
[2] Univ Wisconsin Madison, Dept Elect & Comp Engn, Madison, WI USA
[3] Univ Yamanashi, Dept Radiol, Yamanashi, Japan
[4] Univ Wisconsin Madison, Dept Med Phys, Madison, WI USA
[5] Univ Wisconsin Madison, Dept Biomed Engn, Madison, WI USA
[6] Univ Wisconsin Madison, Dept Med, Madison, WI USA
[7] Univ Wisconsin Madison, Dept Emergency Med, Madison, WI USA
基金
美国国家卫生研究院;
关键词
B-0; B-1; dielectric effect; inhomogeneities; liver; quantitative imaging biomarkers; MAGNETIC-RESONANCE; FIELD INHOMOGENEITY; FAT; WATER; T-1; QUANTIFICATION; SEPARATION; MRI; DECOMPOSITION; DISTORTION;
D O I
10.1002/mrm.28549
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The purpose of this work is to characterize the magnitude and variability of B-0 and B-1 inhomogeneities in the liver in large cohorts of patients at both 1.5 T and 3.0 T. Methods Volumetric B-0 and B-1 maps were acquired over the liver of patients presenting for routine abdominal MRI. Regions of interest were drawn in the nine Couinaud segments of the liver, and the average value was recorded. Magnitude and variation of measured averages in each segment were reported across all patients. Results A total of 316 B-0 maps and 314 B-1 maps, acquired at 1.5 T and 3.0 T on a variety of GE Healthcare MRI systems in 630 unique exams, were identified, analyzed, and, in the interest of reproducible research, de-identified and made public. Measured B-0 inhomogeneities ranged (5th-95th percentiles) from -31.7 Hz to 164.0 Hz for 3.0 T (-14.5 Hz to 81.3 Hz at 1.5 T), while measured B-1 inhomogeneities (ratio of actual over prescribed flip angle) ranged from 0.59 to 1.13 for 3.0 T (0.83 to 1.11 at 1.5 T). Conclusion This study provides robust characterization of B-0 and B-1 inhomogeneities in the liver to guide the development of imaging applications and protocols. Field strength, bore diameter, and sex were determined to be statistically significant effects for both B-0 and B-1 uniformity. Typical clinical liver imaging at 3.0 T should expect B-0 inhomogeneities ranging from approximately -100 Hz to 250 Hz (-50 Hz to 150 Hz at 1.5 T) and B-1 inhomogeneities ranging from approximately 0.4 to 1.3 (0.7 to 1.2 at 1.5 T).
引用
收藏
页码:2212 / 2220
页数:9
相关论文
共 42 条
[1]  
Andrews T, 2010, P 18 ANN M INT SOC M
[2]   Multiparametric magnetic resonance for the non-invasive diagnosis of liver disease [J].
Banerjee, Rajarshi ;
Pavlides, Michael ;
Tunnicliffe, Elizabeth M. ;
Piechnik, Stefan K. ;
Sarania, Nikita ;
Philips, Rachel ;
Collier, Jane D. ;
Booth, Jonathan C. ;
Schneider, Jurgen E. ;
Wang, Lai Mun ;
Delaney, David W. ;
Fleming, Ken A. ;
Robson, Matthew D. ;
Barnes, Eleanor ;
Neubauer, Stefan .
JOURNAL OF HEPATOLOGY, 2014, 60 (01) :69-77
[3]   Fitting Linear Mixed-Effects Models Using lme4 [J].
Bates, Douglas ;
Maechler, Martin ;
Bolker, Benjamin M. ;
Walker, Steven C. .
JOURNAL OF STATISTICAL SOFTWARE, 2015, 67 (01) :1-48
[4]   Imaging artifacts at 3.OT [J].
Bernstein, Matt A. ;
Huston, John, III ;
Ward, Heidi A. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (04) :735-746
[5]   Advanced body composition assessment: from body mass index to body composition profiling [J].
Borga, Magnus ;
West, Janne ;
Bell, Jimmy D. ;
Harvey, Nicholas C. ;
Romu, Thobias ;
Heymsfield, Steven B. ;
Leinhard, Olof Dahlqvist .
JOURNAL OF INVESTIGATIVE MEDICINE, 2018, 66 (05) :887-895
[6]   Clinical Applications of Dual-Channel Transmit MRI: A Review [J].
Brink, Wyger M. ;
Gulani, Vikas ;
Webb, Andrew G. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 42 (04) :855-869
[7]   Standardized Approach for ROI-Based Measurements of Proton Density Fat Fraction and R2*in the Liver [J].
Campo, Camilo A. ;
Hernando, Diego ;
Schubert, Tilman ;
Bookwalter, Candice A. ;
Van Pay, Andrew J. ;
Reeder, Scott B. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2017, 209 (03) :592-603
[8]   Rapid high-resolution T1 mapping by variable flip angles:: Accurate and precise measurements in the presence of radiofrequency field inhomogeneity [J].
Cheng, HLM ;
Wright, GA .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (03) :566-574
[9]   Central brightening due to constructive interference with, without, and despite dielectric resonance [J].
Collins, CM ;
Liu, WZ ;
Schreiber, W ;
Yang, QX ;
Smith, MB .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (02) :192-196
[10]  
DeGraaf RA, 1997, CONCEPT MAGNETIC RES, V9, P247, DOI 10.1002/(SICI)1099-0534(1997)9:4<247::AID-CMR4>3.0.CO