Intrasession Reliability of Force Platform Parameters in Community-Dwelling Older Adults

被引:95
作者
Bauer, Christoph [1 ]
Groeger, Iner
Rupprecht, Roland [2 ]
Gassmann, Karl Guenter
机构
[1] Waldkrankenhaus St Marien, Dept Geriatr & Geriatr Rehabil, Gait & Balance Lab, D-91054 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Inst Psychogerontol, Erlangen, Germany
来源
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION | 2008年 / 89卷 / 10期
关键词
Aged; Posture; Rehabilitation; Reliability and validity;
D O I
10.1016/j.apmr.2008.02.033
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: To investigate the intrasession reliability of center of pressure (COP) parameters calculated from force platform measurements. Design: A cross-sectional study. Setting: Gait and balance laboratory. Participants: Community-dwelling healthy older adults (N=63) above the age of 62 years (mean age, 78.74y). Interventions: Not applicable. Main Outcome Measures: COP was estimated from a force platform, and the following parameters were calculated: (1) the total length of the COP displacement, (2) area of sway, (3) length of the COP displacement in the sagittal plane, and (4) length of the COP displacement in the frontal plane. Intraclass correlation coefficients (ICCs) were calculated by using 3 successive trials with 4 different test conditions. The test conditions were (1) normative standing with eyes open, (2) normative standing with eyes closed, (3) narrow stance with eyes open, and (4) narrow stance with eyes closed. Results: The ICCs for the tests with eyes closed (.710-.946) were higher than those for tests with eyes open (.841-.945). The highest value was obtained for the vector sum of the COP during anteroposterior movement in narrow stance with eyes closed (.946). The value .710 was the lowest of all parameters and was an outlier for the narrow stance with eyes closed test, which was otherwise very reliable. Conclusions: Eight of 16 calculated ICCs showed excellent reliability (>.90). They can be recommended for further use in clinical trials. Tests with closed eyes were more reliable than tests with eyes open. We recommend using eyes closed test conditions when assessing static balance control. For these tests, all the calculated ICCs were over .90, except for measurements of sway area.
引用
收藏
页码:1977 / 1982
页数:6
相关论文
共 42 条
[1]  
[Anonymous], 1990, Balance: Proceedings of the APTA Forum
[2]   COMPARISON OF STATIC AND DYNAMIC POSTUROGRAPHY IN YOUNG AND OLDER NORMAL PEOPLE [J].
BALOH, RW ;
FIFE, TD ;
ZWERLING, L ;
SOCOTCH, T ;
JACOBSON, K ;
BELL, T ;
BEYKIRCH, K .
JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 1994, 42 (04) :405-412
[3]   Prospective study of posturography in normal older people [J].
Baloh, RW ;
Corona, S ;
Jacobson, KM ;
Enrietto, JA ;
Bell, T .
JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 1998, 46 (04) :438-443
[4]   Kinematic characteristics of standing disequilibrium: Reliability and validity of a posturographic protocol [J].
Benvenuti, F ;
Mecacci, R ;
Gineprari, I ;
Bandinelli, S ;
Benvenuti, E ;
Ferrucci, L ;
Baroni, A ;
Rabuffetti, M ;
Hallett, M ;
Dambrosia, JM ;
Stanhope, SJ .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1999, 80 (03) :278-287
[5]  
BERG K, 1995, SCAND J REHABIL MED, V27, P27
[6]  
BERG KO, 1992, ARCH PHYS MED REHAB, V73, P1073
[7]   INFLUENCE OF SUBJECTS HEIGHT ON THE STABILIZATION OF POSTURE [J].
BERGER, W ;
TRIPPEL, M ;
DISCHER, M ;
DIETZ, V .
ACTA OTO-LARYNGOLOGICA, 1992, 112 (01) :22-30
[8]   Risk factors for serious fall related injury in elderly women living at home [J].
Bergland, A ;
Wyller, TB .
INJURY PREVENTION, 2004, 10 (05) :308-313
[9]  
BIZZO G, 1984, Agressologie, V25, P1033
[10]  
BLACK FO, 1985, VESTIBULAR VISUAL CO, P271