A comparative study between multiple cannulated screws and dynamic hip screw for fixation of femoral neck fracture in adults

被引:62
作者
Siavashi, Babak [1 ]
Aalirezaei, Arash [1 ]
Moosavi, Mersad [1 ]
Golbakhsh, Mohammad Reza [1 ]
Savadkoohi, Dariush [1 ]
Zehtab, Mohammad Javad [1 ]
机构
[1] Univ Tehran Med Sci, Dept Orthoped Surg, Tehran, Iran
关键词
Fracture; Neck of femur; Cannulated screw; Dynamic hip screw; INTERNAL-FIXATION; FEMUR; QUANTIFICATION; NAIL;
D O I
10.1007/s00264-015-2881-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose In younger adults with fractures of the femoral neck, anatomic reduction is compulsory and maintaining the reduction is crucial. Both cannulated screws and dynamic hip screw (DHS) have the capacity of compression in the fracture site but the strength for keeping reduction is not the same. The aim of this study was to compare the results with fixations of the femoral neck fractures with cannulated screws versus dynamic hip screw. Methods This is a randomized clinical trial study on 58 cases with a minimum of one year follow-up. Leg length discrepancy, Harris Hip Score, infection, avascular necrosis of femoral head, and union of the fracture site were evaluated. Results There were two failures in the first trimester in the cannulated screw group and three more failures in the second and third trimesters in this group. In the DHS group, there was no reduction and fixation failure in the follow-up period. There was no fixation failure (0 %) in Group B (DHS) but there were five fixation failures (18 %) in Group A (screw), and there is significant difference between the groups (p < 0.001). The rate of avascular necrosis was the same in both groups. Conclusions It seems to us that in our practice the fixation of femoral neck fracture in young adults with the DHS is a better option compared with the osteosynthsis with multiple cannulated screws.
引用
收藏
页码:2069 / 2071
页数:3
相关论文
共 24 条
[1]   Prospective randomised controlled trial of an intramedullary nail versus a sliding hip screw for intertrochanteric fractures of the femur [J].
Aktselis, Ioannis ;
Kokoroghiannis, Constantine ;
Fragkomichalos, Evaggelos ;
Koundis, Georgios ;
Deligeorgis, Anastasios ;
Daskalakis, Emmanouil ;
Vlamis, John ;
Papaioannou, Nikolaos .
INTERNATIONAL ORTHOPAEDICS, 2014, 38 (01) :155-161
[2]   Radiographic quantification of dynamic hip screw migration [J].
Audige, Laurent ;
Cagienard, Flurin ;
Sprecher, Christoph Martin ;
Suhm, Norbert ;
Mueller, Marc Andreas .
INTERNATIONAL ORTHOPAEDICS, 2014, 38 (04) :839-845
[3]   The history of internal fixation of proximal femur fractures Ernst Pohl-the genius behind [J].
Bartonicek, Jan ;
Rammelt, Stefan .
INTERNATIONAL ORTHOPAEDICS, 2014, 38 (11) :2421-2426
[4]  
Baumgaertner M R., 2001, Rockwood and Green's fracture in Adults, V5th
[5]  
BLAIR B, 1994, CLIN ORTHOP RELAT R, P256
[6]  
BRODETTI A, 1960, J BONE JOINT SURG BR, V42, P794, DOI 10.1302/0301-620X.42B4.794
[7]   Predictors of early failure of fixation in the treatment of displaced subcapital hip fractures [J].
Chua, D ;
Jaglal, SB ;
Schatzker, J .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1998, 12 (04) :230-234
[8]   COMPLICATIONS OF FEMORAL-NECK FRACTURE IN YOUNG-ADULTS [J].
DEDRICK, DK ;
MACKENZIE, JR ;
BURNEY, RE .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1986, 26 (10) :932-937
[9]   Delayed union of an operated fracture of the femoral neck [J].
Dhar S.A. ;
Gani N.U. ;
Butt M.F. ;
Farooq M. ;
Mir M.R. .
Journal of Orthopaedics and Traumatology, 2008, 9 (2) :97-99
[10]   Locked Plating: Biomechanics and Biology [J].
Dickson, Kyle F. ;
Munz, John W. .