Assessment of spatial normalization of PET ligand images using ligand-specific templates

被引:161
作者
Meyer, JH
Gunn, RN
Myers, R
Grasby, PM
机构
[1] Hammersmith Hosp, Imperial Coll Sch Med, MRC, Cyclotron Unit, London W12 0NN, England
[2] Clarke Inst Psychiat, PET Ctr, Toronto, ON M5T 1R8, Canada
基金
英国医学研究理事会;
关键词
D O I
10.1006/nimg.1999.0431
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Recent advances allow robust computation of parametric maps of ligand-receptor binding from PET data sets. Parametric maps may be statistically analyzed at the voxel level, given suitable techniques for both the spatial normalization of image data into a standard space and the application of appropriate statistical tests. The purpose of this study was to spatially normalize parametric maps of [carbonyl-C-11]WAY-100635 and [C-11]raclopride binding using SPM 96 and ligand-specific templates. Ligand-specific templates were created from integral images taken from healthy subjects. For this, a MRI-based spatial normalization was used: T1-weighted MRI scans were coregistered to the PET integral images, and the spatial normalization of the MRI to the SPM 96 T1 MRI template was applied to the integral images. These integral images were meaned and smoothed to form [carbonyl-C-11]WAY-100635 and [C-11]raclopride templates, Reliability of spatial normalization using the ligand template method and the previous MRI-based spatial normalization was investigated by using a second set of integral images taken from a different cohort: Landmark coordinates were defined on all spatially normalized integral images. Mean coordinates were found in order to produce an overall (average) landmark for each location. For each image, at each location, the distance from the landmark coordinates to the overall landmark were found. A multivariate analysis of variance was used to examine the effects of observer variance, landmark location, and the method used. Visually acceptable templates were created. While observer variance was not significant, the landmark x method interaction was significant. The ligand template method had significantly smaller distances: Among the landmark locations with this method, the mean distances between individual image landmarks and overall image landmarks ranged from 1.1 to 4.9 mm. The ligand template method provides a reliable approach for spatial normalization of PET ligand images.
引用
收藏
页码:545 / 553
页数:9
相关论文
共 24 条
[1]   Incorporating prior knowledge into image registration [J].
Ashburner, J ;
Neelin, P ;
Collins, DL ;
Evans, A ;
Friston, K .
NEUROIMAGE, 1997, 6 (04) :344-352
[2]   Suppression of noise artifacts in spectral analysis of dynamic PET data [J].
Cunningham, VJ ;
Gunn, RN ;
Byrne, H ;
Matthews, JC .
QUANTITATIVE FUNCTIONAL BRAIN IMAGING WITH POSITRON EMISSION TOMOGRAPHY, 1998, :329-334
[3]   Stereotaxic summation analysis of human cerebral benzodiazepine binding maps [J].
Frey, KA ;
Minoshima, S ;
Koeppe, RA ;
Kilbourn, MR ;
Berger, KL ;
Kuhl, DE .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1996, 16 (03) :409-417
[4]   PARAMETRIC INVIVO IMAGING OF BENZODIAZEPINE RECEPTOR DISTRIBUTION IN HUMAN BRAIN [J].
FREY, KA ;
HOLTHOFF, VA ;
KOEPPE, RA ;
JEWETT, DM ;
KILBOURN, MR ;
KUHL, DE .
ANNALS OF NEUROLOGY, 1991, 30 (05) :663-672
[5]  
Friston K., 1995, HUM BRAIN MAP, V2, P165, DOI DOI 10.1002/HBM.460030303
[6]  
Friston K. J., 1995, HUMAN BRAIN MAPPING, V2, P189, DOI [10.1002/hbm.460020402, DOI 10.1002/HBM.460020402]
[7]   PLASTIC TRANSFORMATION OF PET IMAGES [J].
FRISTON, KJ ;
FRITH, CD ;
LIDDLE, PF ;
FRACKOWIAK, RSJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (04) :634-639
[8]   Correction for scatter in 3D brain PET using a dual energy window method [J].
Grootoonk, S ;
Spinks, TJ ;
Sashin, D ;
Spyrou, NM ;
Jones, T .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (12) :2757-2774
[9]   Parametric imaging of ligand-receptor binding in PET using a simplified reference region model [J].
Gunn, RN ;
Lammertsma, AA ;
Hume, SP ;
Cunningham, VJ .
NEUROIMAGE, 1997, 6 (04) :279-287
[10]  
GUNN RN, 1998, IN PRESS NEUROIMAGE