Biological pacemaker created by percutaneous gene delivery via venous catheters in a porcine model of complete heart block

被引:39
作者
Cingolani, Eugenio [1 ]
Yee, Kristine [1 ]
Shehata, Michael [1 ]
Chugh, Sumeet S. [1 ]
Marban, Eduardo [1 ]
Cho, Hee Cheol [1 ]
机构
[1] Cedars Sinai Heart Inst, Los Angeles, CA 90048 USA
关键词
Biological pacemaker; In vivo gene transfer; Preclincal large animal model; Pacemaker device infection; Temporary pacing; CARDIAC DEVICE INFECTIONS; LEFT-VENTRICULAR FUNCTION; INTEGRATION; MANAGEMENT; CELLS; CARDIOMYOCYTES; DEFIBRILLATOR; EXPRESSION; INSIGHTS; RATES;
D O I
10.1016/j.hrthm.2012.04.020
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Pacemaker-dependent patients with device infection require temporary pacing while the infection is treated. External transthoracic pacing is painful and variably effective, while temporary pacing leads are susceptible to superinfection. OBJECTIVE To create a biological pacemaker delivered via venous catheters in a porcine model of complete heart block, providing a temporary alternative/adjunct to external pacing devices without additional indwelling hardware. METHODS Complete atrioventricular (AV) nodal block was induced in pigs by radiofrequency ablation after the implantation of a single-chamber electronic pacemaker to maintain a ventricular backup rate of 50 beats/min. An adenoviral vector cocktail (K-AAA + H2), expressing dominant-negative inward rectifier potassium channel (Kir2.1AAA) and hyperpolarization-activated cation channel (HCN2) genes, was injected into the AV junctional region via a NOGA Myostar catheter advanced through the femoral vein. RESULTS Animals injected with K-AAA + H2 maintained a physiologically relevant ventricular rate of 93.5 +/- 7 beats/min (n = 4) compared with control animals (average rate, 59.4 +/- 4 beats/min; n = 6 at day 7 postinjection; P < .05). Backup electronic pacemaker utilization decreased by almost 4-fold in the K-AAA + H2 group compared with the control (P < .05), an effect maintained for the entire 14-day window. In contrast to the efficacy of gene delivery into the AV junctional region, open-chest, direct injection of K-AAA + H2 (or its individual vectors) into the ventricular myocardium failed to elicit significant pacemaker activity. CONCLUSIONS The right-sided delivery of K-AAA + H2 to the AV junctional region provided physiologically relevant biological pacing over a 14-day period. Our approach may provide temporary, bridge-to-device pacing for the effective clearance of infection prior to the reimplantation of a definitive electronic pacemaker.
引用
收藏
页码:1310 / 1318
页数:9
相关论文
共 42 条
  • [1] The Anatomy of the Cardiac Conduction System
    Anderson, Robert H.
    Yanni, Joseph
    Boyett, Mark R.
    Chandler, Natalie J.
    Dobrzynski, Halina
    [J]. CLINICAL ANATOMY, 2009, 22 (01) : 99 - 113
  • [2] ARMON C, 1993, NEW ENGL J MED, V329, P1277
  • [3] Regional survey of temporary transvenous pacing procedures and complications
    Betts, TR
    [J]. POSTGRADUATE MEDICAL JOURNAL, 2003, 79 (934) : 463 - 466
  • [4] Adeno-Associated Virus (AAV) Serotype 9 Provides Global Cardiac Gene Transfer Superior to AAV1, AAV6, AAV7, and AAV8 in the Mouse and Rat
    Bish, Lawrence T.
    Morine, Kevin
    Sleeper, Meg M.
    Sanmiguel, Julio
    Wu, Di
    Gao, Guangping
    Wilson, James M.
    Sweeney, H. Lee
    [J]. HUMAN GENE THERAPY, 2008, 19 (12) : 1359 - 1368
  • [5] Increasing rates of cardiac device infections among Medicare beneficiaries: 1990-1999
    Cabell, CH
    Heidenreich, PA
    Chu, VH
    Moore, CM
    Stryjewski, ME
    Corey, GR
    Fowler, VG
    [J]. AMERICAN HEART JOURNAL, 2004, 147 (04) : 582 - 586
  • [6] Acute myocardial infarction complicated by ventricular standstill terminated by thrombolysis and transcutaneous pacing
    Castle, Nick
    Porter, Crispin
    Thompson, Beverley
    [J]. RESUSCITATION, 2007, 74 (03) : 559 - 562
  • [7] CHARDACK WM, 1960, SURGERY, V48, P643
  • [8] Biological Therapies for Cardiac Arrhythmias Can Genes and Cells Replace Drugs and Devices?
    Cho, Hee Cheol
    Marban, Eduardo
    [J]. CIRCULATION RESEARCH, 2010, 106 (04) : 674 - 685
  • [9] Diagnosis and management of infections involving implantable electrophysiologic cardiac devices
    Chua, JD
    Wilkoff, BL
    Lee, I
    Juratli, N
    Longworth, DL
    Gordon, SM
    [J]. ANNALS OF INTERNAL MEDICINE, 2000, 133 (08) : 604 - 608
  • [10] Epstein AE, 2008, J AM COLL CARDIOL, V51, pe1, DOI DOI 10.1111/J.1540-8167.2012.02394.X