Quantitative in vitro comparison of the thrombogenicity of commercial dental implants

被引:13
作者
Milleret, Vincent [1 ]
Lienemann, Philipp S. [2 ]
Bauer, Sebastian [3 ]
Ehrbar, Martin [1 ]
机构
[1] Univ Zurich, Univ Hosp Zurich, Dept Obstet, Lab Cell & Tissue Engn, Schmelzbergstr 12, CH-8091 Zurich, Switzerland
[2] Nobel Biocare AG, Prod Dev Regenerat & Biol, Kloten, Switzerland
[3] Nobel Biocare AG, Mat Res & Surface Technol, Kloten, Switzerland
关键词
coagulation; dental implant; fibrin coverage; platelet activation; surface properties; thrombogenicity; BLOOD-CLOT; TITANIUM; SURFACES; OSSEOINTEGRATION; HYDROPHILICITY; NANOSTRUCTURES; BIOMATERIAL; CELL;
D O I
10.1111/cid.12737
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background Dental implants often have surface modifications that alter surface topography and chemistry to improve osseointegration and thereby increase treatment predictability. Surface contact-induced blood coagulation is associated with the onset of osseointegration. Purpose To quantitatively evaluate the thrombogenicity of two commercially available dental implants that have similar surface roughness but different surface chemistry. Material and Methods Two commercially available dental implants with anodized or sandblasted acid-etched surfaces were evaluated for thrombogenic properties. Thrombogenicity was assessed by incubating implants for 1 hour in fresh, partially heparinized blood followed by hemocyte quantification, microscopic evaluation, and quantification of thrombogenic biomarkers. Results Fibrin coverage was significantly higher on the anodized surface compared with the sandblasted acid-etched surface (P < 0.0001). Platelet and white blood cell attachment followed a similar pattern. The increased thrombogenicity was confirmed based on a significant increase in the levels of the coagulation cascade biomarkers, thrombin antithrombin complex, and beta-thromboglobulin (all P < 0.05). Conclusion Dental implants with comparable roughness but differing surface chemistry had differing extents of blood contact activation. These data suggest that surface chemistry from anodization augments implant thrombogenicity compared with that from sandblasting and acid-etching, which could have implications for osseointegration.
引用
收藏
页码:8 / 14
页数:7
相关论文
共 50 条
  • [31] Analysis of percussion response of dental implants: An in vitro study
    Dinh, Andrew
    Sheets, Cherilyn G.
    Earthman, James C.
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2013, 33 (05): : 2657 - 2663
  • [32] Smoking and dental implants
    Kasat, V.
    Ladda, R.
    JOURNAL OF INTERNATIONAL SOCIETY OF PREVENTIVE AND COMMUNITY DENTISTRY, 2012, 2 (02) : 38 - 41
  • [33] Influence of the Elastic Modulus on the Osseointegration of Dental Implants
    Brizuela, Aritza
    Herrero-Climent, Mariano
    Rios-Carrasco, Elisa
    Vicente Rios-Santos, Jose
    Perez, Roman A.
    Maria Manero, Jose
    Gil Mur, Javier
    MATERIALS, 2019, 12 (06):
  • [34] Advancing osseointegration research: A dynamic three-dimensional (3D) in vitro culture model for dental implants
    Komatsu, Keiji
    Chao, Denny
    Matsuura, Takanori
    Kido, Daisuke
    Ogawa, Takahiro
    JOURNAL OF DENTAL SCIENCES, 2025, 20 (01) : 350 - 360
  • [35] EFFECTS OF NEAR-FIELD ULTRASOUND STIMULATION ON NEW BONE FORMATION AND OSSEOINTEGRATION OF DENTAL TITANIUM IMPLANTS IN VITRO AND IN VIVO
    Hsu, Shih-Kuang
    Huang, Wen-Tao
    Liu, Bai-Shuan
    Li, Shih-Miao
    Chen, Hsien-Te
    Chang, Chen-Jung
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2011, 37 (03) : 403 - 416
  • [36] Effect of different cone beam computed tomography settings on artifact production in titanium and zirconia dental implants: An in vitro study
    Kuzu, Turan Emre
    Kis, Hatice Cansu
    DENTAL AND MEDICAL PROBLEMS, 2024, 61 (02) : 233 - 239
  • [37] In Vitro Thrombogenicity Testing of Biomaterials
    Braune, Steffen
    Latour, Robert A.
    Reinthaler, Markus
    Landmesser, Ulf
    Lendlein, Andreas
    Jung, Friedrich
    ADVANCED HEALTHCARE MATERIALS, 2019, 8 (21)
  • [38] Assessing the Impact of Various Decontamination Instruments on Titanium and Zirconia Dental Implants: An In Vitro Study
    Vierling, Louisa
    Liu, Chun Ching
    Wiedemeier, Daniel
    Gubler, Andrea
    Schmidlin, Patrick R.
    DENTISTRY JOURNAL, 2024, 12 (05)
  • [39] In vitro assessment of artifacts induced by titanium dental implants in cone beam computed tomography
    Benic, Goran I.
    Sancho-Puchades, Manuel
    Jung, Ronald E.
    Deyhle, Hans
    Haemmerle, Christoph H. F.
    CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 (04) : 378 - 383
  • [40] Comparison of conventional and synchrotron radiation based microtomography of bone around dental implants
    Cattaneo, PM
    Dalstra, M
    Beckmann, F
    Donath, T
    Melsen, B
    DEVELOPMENTS IN X-RAY TOMOGRAPHY IV, 2004, 5535 : 757 - 764