Quantitative in vitro comparison of the thrombogenicity of commercial dental implants

被引:13
|
作者
Milleret, Vincent [1 ]
Lienemann, Philipp S. [2 ]
Bauer, Sebastian [3 ]
Ehrbar, Martin [1 ]
机构
[1] Univ Zurich, Univ Hosp Zurich, Dept Obstet, Lab Cell & Tissue Engn, Schmelzbergstr 12, CH-8091 Zurich, Switzerland
[2] Nobel Biocare AG, Prod Dev Regenerat & Biol, Kloten, Switzerland
[3] Nobel Biocare AG, Mat Res & Surface Technol, Kloten, Switzerland
关键词
coagulation; dental implant; fibrin coverage; platelet activation; surface properties; thrombogenicity; BLOOD-CLOT; TITANIUM; SURFACES; OSSEOINTEGRATION; HYDROPHILICITY; NANOSTRUCTURES; BIOMATERIAL; CELL;
D O I
10.1111/cid.12737
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background Dental implants often have surface modifications that alter surface topography and chemistry to improve osseointegration and thereby increase treatment predictability. Surface contact-induced blood coagulation is associated with the onset of osseointegration. Purpose To quantitatively evaluate the thrombogenicity of two commercially available dental implants that have similar surface roughness but different surface chemistry. Material and Methods Two commercially available dental implants with anodized or sandblasted acid-etched surfaces were evaluated for thrombogenic properties. Thrombogenicity was assessed by incubating implants for 1 hour in fresh, partially heparinized blood followed by hemocyte quantification, microscopic evaluation, and quantification of thrombogenic biomarkers. Results Fibrin coverage was significantly higher on the anodized surface compared with the sandblasted acid-etched surface (P < 0.0001). Platelet and white blood cell attachment followed a similar pattern. The increased thrombogenicity was confirmed based on a significant increase in the levels of the coagulation cascade biomarkers, thrombin antithrombin complex, and beta-thromboglobulin (all P < 0.05). Conclusion Dental implants with comparable roughness but differing surface chemistry had differing extents of blood contact activation. These data suggest that surface chemistry from anodization augments implant thrombogenicity compared with that from sandblasting and acid-etching, which could have implications for osseointegration.
引用
收藏
页码:8 / 14
页数:7
相关论文
共 50 条
  • [1] Surface characteristics on commercial dental implants differentially activate macrophages in vitro and in vivo
    Abaricia, Jefferson O.
    Shah, Arth H.
    Ruzga, Marissa N.
    Olivares-Navarrete, Rene
    CLINICAL ORAL IMPLANTS RESEARCH, 2021, 32 (04) : 487 - 497
  • [2] Fibrin Clot Extension on Zirconia Surface for Dental Implants: A Quantitative In Vitro Study
    Traini, Tonino
    Caputi, Sergio
    Gherlone, Enrico
    Degidi, Marco
    Piattelli, Adriano
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2014, 16 (05) : 718 - 727
  • [3] An in vitro biofilm model associated to dental implants: Structural and quantitative analysis of in vitro biofilm formation on different dental implant surfaces
    Sanchez, M. C.
    Llama-Palacios, A.
    Fernandez, E.
    Figuero, E.
    Marin, M. J.
    Leon, R.
    Blanc, V.
    Herrera, D.
    Sanz, M.
    DENTAL MATERIALS, 2014, 30 (10) : 1161 - 1171
  • [4] Topographic characterisation of dental implants for commercial use
    Mendoza-Arnau, Amparo
    Vallecillo-Capilla, Manuel-Francisco
    Cabrerizo-Vilchez, Miguel-Angel
    Rosales-Leal, Juan-Ignacio
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2016, 21 (05): : E631 - E636
  • [5] Measuring Luxation of Dental Implants In Vitro
    Ilies, Horea T.
    Flanagan, Dennis
    Raby, Matthew
    Stevenson, Richard
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2008, 2 (01):
  • [6] ANALYSIS OF SURFACE CLEANLINESS OF 3 COMMERCIAL DENTAL IMPLANTS
    EDWARDS, BN
    GOLD, BR
    BIOMATERIALS, 1992, 13 (11) : 775 - 780
  • [7] Morphology and microchemistry study of three commercial dental implants
    Ausiello, Pietro
    Bolli, Eleonora
    Kaciulis, Saulius
    Gloria, Antonio
    Lanzotti, Antonio
    Martorelli, Massimo
    Mezzi, Alessio
    Montanari, Roberto
    Richetta, Maria
    Varone, Alessandra
    SURFACE AND INTERFACE ANALYSIS, 2023, 55 (6-7) : 411 - 416
  • [8] CHARACTERIZATION OF COMMERCIAL HA-COATED DENTAL IMPLANTS
    KIM, Y
    LEGEROS, J
    LEGEROS, R
    JOURNAL OF DENTAL RESEARCH, 1994, 73 : 137 - 137
  • [9] COMPARISON OF THE PRIMARY STABILITIES OF CONICAL AND CYLINDRICAL ENDOSSEOUS DENTAL IMPLANTS: AN IN-VITRO STUDY
    Aleo, E.
    Varvara, G.
    Scarano, A.
    Sinjari, B.
    Murmura, G.
    JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2012, 26 (01): : 89 - 96
  • [10] TRIBOCORROSION IN DENTAL IMPLANTS: AN IN-VITRO STUDY
    Figueiredo-Pina, C. G.
    Moreira, V.
    Colaco, R.
    Serro, A. P.
    PROCEEDINGS OF VIII INTERNATIONAL SCIENTIFIC CONFERENCE (BALTTRIB' 2015), 2016, : 122 - 125