Employing an Intercalated Redox Reporter in Electrochemical Aptamer-Based Biosensors to Enable Calibration-Free Molecular Measurements in Undiluted Serum

被引:35
作者
Zhu, Man [1 ]
Li, Shaoguang [1 ]
Li, Hongxing [1 ]
Li, Hui [1 ]
Xia, Fan [1 ]
机构
[1] China Univ Geosci, Fac Mat Sci & Chem, Minist Educ, Engn Res Ctr Nanogeomat, Wuhan 430074, Peoples R China
基金
中国国家自然科学基金;
关键词
BLOOD-SERUM; LABEL-FREE; DNA; SIGNAL; REAGENTLESS; PERFORMANCE; APTASENSOR;
D O I
10.1021/acs.analchem.0c02205
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrochemical aptamer-based (E-AB) biosensors suffer from sensor-to-sensor signal variations due to the variation of the total number and the heterogeneity of probes immobilized on the electrode surface, with the former attracting more attention. As such, a calibration process to correct for such variations is required for this type of sensor, causing inconvenience and inaccessibility in harsh sensing environments such as blood samples, which has dramatically limited the widespread clinical use of biosensors. In response, here, we have adopted E-AB sensors to achieve calibration-free measurements of small biological/drug molecules. Specifically, we employ one probe-attached redox reporter and a second intercalated redox reporter to generate two signals, achieving good sensor-to-sensor reproducibility and thus obviating the need for calibration. We first demonstrated the capability of E-AB sensors for the accurate measurement of kanamycin, tobramycin, and adenosine triphosphate (ATP) in phosphate-buffered saline (PBS) buffer, achieving concentration ranges of approximately 4.7 x 10(3)-, 2.0 x 10(3)-, and 12.7-fold, respectively. Then, we applied this calibration-free approach to the measurement of these three target molecules directly in undiluted serum, achieving a concentration precision of a few micromolars.
引用
收藏
页码:12437 / 12441
页数:5
相关论文
共 27 条
[1]   Intercalation of quantum dots as the new signal acquisition and amplification platform for sensitive electrochemiluminescent detection of microRNA [J].
Chen, Ying ;
Xiang, Yun ;
Yuan, Ruo ;
Chai, Yaqin .
ANALYTICA CHIMICA ACTA, 2015, 891 :130-135
[2]   High-Performance Ratiometric Electrochemical Method Based on the Combination of Signal Probe and Inner Reference Probe in One Hairpin-Structured DNA [J].
Deng, Chunyan ;
Pi, Xiaomei ;
Qian, Pin ;
Chen, Xiaoqing ;
Wu, Wuming ;
Xiang, Juan .
ANALYTICAL CHEMISTRY, 2017, 89 (01) :966-973
[3]   Electrochemical interrogation of conformational changes as a reagentless method for the sequence-specific detection of DNA [J].
Fan, CH ;
Plaxco, KW ;
Heeger, AJ .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2003, 100 (16) :9134-9137
[4]   A DNA APTAMER THAT BINDS ADENOSINE AND ATP [J].
HUIZENGA, DE ;
SZOSTAK, JW .
BIOCHEMISTRY, 1995, 34 (02) :656-665
[5]   Seconds-resolved pharmacokinetic measurements of the chemotherapeutic irinotecan in situ in the living body [J].
Idili, Andrea ;
Arroyo-Curras, Netzahualcoyotl ;
Ploense, Kyle L. ;
Csordas, Andrew T. ;
Kuwahara, Masayasu ;
Kippin, Tod E. ;
Plaxco, Kevin W. .
CHEMICAL SCIENCE, 2019, 10 (35) :8164-8170
[6]   High frequency, calibration-free molecular measurements in situ in the living body [J].
Li, Hui ;
Li, Shaoguang ;
Dai, Jun ;
Li, Chengcheng ;
Zhu, Man ;
Li, Hongxing ;
Lou, Xiaoding ;
Xia, Fan ;
Plaxco, Kevin W. .
CHEMICAL SCIENCE, 2019, 10 (47) :10843-10848
[7]   Calibration-Free Electrochemical Biosensors Supporting Accurate Molecular Measurements Directly in Undiluted Whole Blood [J].
Li, Hui ;
Dauphin-Ducharme, Philippe ;
Ortega, Gabriel ;
Plaxco, Kevin W. .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2017, 139 (32) :11207-11213
[8]   A Biomimetic Phosphatidylcholine-Terminated Monolayer Greatly Improves the In Vivo Performance of Electrochemical Aptamer-Based Sensors [J].
Li, Hui ;
Dauphin-Ducharme, Philippe ;
Arroyo-Curras, Netzahualcoyotl ;
Tran, Claire H. ;
Vieira, Philip A. ;
Li, Shaoguang ;
Shin, Christina ;
Somerson, Jacob ;
Kippin, Tod E. ;
Plaxco, Kevin W. .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2017, 56 (26) :7492-7495
[9]   A simple regenerable electrochemical aptasensor for the parallel and continuous detection of biomarkers [J].
Liu, Chunyan ;
Liu, Xi ;
Qin, Yun ;
Deng, Chunyan ;
Xiang, Juan .
RSC ADVANCES, 2016, 6 (63) :58469-58476
[10]   Real-time monitoring of peroxynitrite (ONOO-) in the rat brain by developing a ratiometric electrochemical biosensor [J].
Liu, Feiyue ;
Dong, Hui ;
Tian, Yang .
ANALYST, 2019, 144 (06) :2150-2157