Compressed Sensing Reconstruction Improves Sensitivity of Variable Density Spiral fMRI

被引:28
|
作者
Holland, D. J. [1 ]
Liu, C. [2 ]
Song, X. [2 ]
Mazerolle, E. L. [2 ,3 ]
Stevens, M. T. [2 ,4 ]
Sederman, A. J. [1 ]
Gladden, L. F. [1 ]
D'Arcy, R. C. N. [2 ,3 ,5 ]
Bowen, C. V. [2 ,4 ,5 ,6 ]
Beyea, S. D. [2 ,4 ,5 ,6 ]
机构
[1] Univ Cambridge, Dept Chem Engn & Biotechnol, Cambridge, England
[2] Natl Res Council Canada, Inst Biodiagnost Atlantic, Halifax, NS, Canada
[3] Dalhousie Univ, Dept Psychol & Neurosci, Halifax, NS, Canada
[4] Dalhousie Univ, Dept Phys, Halifax, NS B3H 3J5, Canada
[5] Dalhousie Univ, Dept Radiol, Halifax, NS, Canada
[6] Dalhousie Univ, Sch Biomed Engn, Halifax, NS, Canada
基金
加拿大自然科学与工程研究理事会; 英国工程与自然科学研究理事会;
关键词
fMRI; compressed sensing; variable-density; spiral; IMAGE COMPRESSION; HIGH-SPEED; MRI; RESOLUTION; ROBUST; OPTIMIZATION; ACQUISITION; REGISTRATION; TRAJECTORIES; PRINCIPLES;
D O I
10.1002/mrm.24621
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeFunctional MRI (fMRI) techniques that can provide excellent blood oxygen level dependent contrast, rapid whole brain imaging, and minimal spatial distortion are in demand. This study explored whether fMRI sensitivity can be improved through the use of compressed sensing (CS) reconstruction of variable density spiral fMRI. MethodsThree different CS-reconstructed 1-shot variable density spirals were explored (corresponding to 28%, 35%, and 46% under-sampling), and compared with conventional 1-shot and 2-shot Archimedean spirals acquired using matched echo time and volume repetition time. fMRI maps were reconstructed with or without CS MRI and sensitivity was compared using identically matched voxels. ResultsThe results demonstrated that an l(1)-norm based CS reconstruction only led to an increase in functional contrast when applied to 28% under-sampled data. A whole brain t-contrast map revealed that 2-shot uniformly sampled spiral and 28% under-sampled spiral data reconstructed with CS yield equivalent sensitivity, even with matched echo time and volume repetition time ConclusionVD spiral exhibits a useful operating range, in the region of 25-30% under-sampling, for which CS reconstruction can be used to increase the sensitivity of fMRI to brain activity. Using CS, VD acquisitions achieve the same sensitivity as 2-shot Archimedean acquisitions, but require only a single shot. Magn Reson Med 70:1634-1643, 2013. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:1634 / 1643
页数:10
相关论文
共 50 条
  • [31] Sensitivity to Basis Mismatch in Compressed Sensing
    Chi, Yuejie
    Scharf, Louis L.
    Pezeshki, Ali
    Calderbank, A. Robert
    IEEE TRANSACTIONS ON SIGNAL PROCESSING, 2011, 59 (05) : 2182 - 2195
  • [32] SENSITIVITY TO BASIS MISMATCH IN COMPRESSED SENSING
    Chi, Yuejie
    Pezeshki, Ali
    Scharf, Louis
    Calderbank, Robert
    2010 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, 2010, : 3930 - 3933
  • [33] Medical Image Compressed Sensing Reconstruction
    Yan Haixia
    Liu Yanjun
    Sun Yuming
    MECHATRONICS ENGINEERING, COMPUTING AND INFORMATION TECHNOLOGY, 2014, 556-562 : 4835 - 4838
  • [34] Variable Density Compressed Image Sampling
    Wang, Zhongmin
    Arce, Gonzalo R.
    IEEE TRANSACTIONS ON IMAGE PROCESSING, 2010, 19 (01) : 264 - 270
  • [35] Embedded Magnetic Resonance Image Reconstruction Using Compressed Sensing
    Amer, Yassin A.
    El-Tager, Mostafa A.
    El-Alamy, Ehab A.
    Abdel-Salam, Ahmed
    Kadah, Yasser M.
    2012 CAIRO INTERNATIONAL BIOMEDICAL ENGINEERING CONFERENCE (CIBEC), 2012, : 35 - 38
  • [36] COMPARISON OF RECONSTRUCTION ALGORITHMS IN COMPRESSED SENSING APPLIED TO BIOLOGICAL IMAGING
    Le Montagner, Yoann
    Angelini, Elsa
    Olivo-Marin, Jean-Christophe
    2011 8TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2011, : 105 - 108
  • [37] Reconstruction of Cardiac Perfusion MRI with Motion Compensated Compressed Sensing
    Tolouee, Azar
    Alirezaie, Javad
    Babyn, Paul
    2020 IEEE 5TH MIDDLE EAST AND AFRICA CONFERENCE ON BIOMEDICAL ENGINEERING (MECBME), 2020, : 24 - 28
  • [38] Evaluation of Variable Density and Data-Driven K-Space Undersampling for Compressed Sensing Magnetic Resonance Imaging
    Zijlstra, Frank
    Viergever, Max A.
    Seevinck, Peter R.
    INVESTIGATIVE RADIOLOGY, 2016, 51 (06) : 410 - 419
  • [39] Accelerated whole-heart MR angiography using a variable-density poisson-disc undersampling pattern and compressed sensing reconstruction
    Moghari, Mehdi H.
    Uecker, Martin
    Roujol, Sebastien
    Sabbagh, Majid
    Geva, Tal
    Powell, Andrew J.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (02) : 761 - 769
  • [40] Spatial excitation using variable-density spiral trajectories
    Schröder, C
    Börnert, P
    Aldefeld, B
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 18 (01) : 136 - 141