Compressed Sensing Reconstruction Improves Sensitivity of Variable Density Spiral fMRI

被引:28
|
作者
Holland, D. J. [1 ]
Liu, C. [2 ]
Song, X. [2 ]
Mazerolle, E. L. [2 ,3 ]
Stevens, M. T. [2 ,4 ]
Sederman, A. J. [1 ]
Gladden, L. F. [1 ]
D'Arcy, R. C. N. [2 ,3 ,5 ]
Bowen, C. V. [2 ,4 ,5 ,6 ]
Beyea, S. D. [2 ,4 ,5 ,6 ]
机构
[1] Univ Cambridge, Dept Chem Engn & Biotechnol, Cambridge, England
[2] Natl Res Council Canada, Inst Biodiagnost Atlantic, Halifax, NS, Canada
[3] Dalhousie Univ, Dept Psychol & Neurosci, Halifax, NS, Canada
[4] Dalhousie Univ, Dept Phys, Halifax, NS B3H 3J5, Canada
[5] Dalhousie Univ, Dept Radiol, Halifax, NS, Canada
[6] Dalhousie Univ, Sch Biomed Engn, Halifax, NS, Canada
基金
加拿大自然科学与工程研究理事会; 英国工程与自然科学研究理事会;
关键词
fMRI; compressed sensing; variable-density; spiral; IMAGE COMPRESSION; HIGH-SPEED; MRI; RESOLUTION; ROBUST; OPTIMIZATION; ACQUISITION; REGISTRATION; TRAJECTORIES; PRINCIPLES;
D O I
10.1002/mrm.24621
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeFunctional MRI (fMRI) techniques that can provide excellent blood oxygen level dependent contrast, rapid whole brain imaging, and minimal spatial distortion are in demand. This study explored whether fMRI sensitivity can be improved through the use of compressed sensing (CS) reconstruction of variable density spiral fMRI. MethodsThree different CS-reconstructed 1-shot variable density spirals were explored (corresponding to 28%, 35%, and 46% under-sampling), and compared with conventional 1-shot and 2-shot Archimedean spirals acquired using matched echo time and volume repetition time. fMRI maps were reconstructed with or without CS MRI and sensitivity was compared using identically matched voxels. ResultsThe results demonstrated that an l(1)-norm based CS reconstruction only led to an increase in functional contrast when applied to 28% under-sampled data. A whole brain t-contrast map revealed that 2-shot uniformly sampled spiral and 28% under-sampled spiral data reconstructed with CS yield equivalent sensitivity, even with matched echo time and volume repetition time ConclusionVD spiral exhibits a useful operating range, in the region of 25-30% under-sampling, for which CS reconstruction can be used to increase the sensitivity of fMRI to brain activity. Using CS, VD acquisitions achieve the same sensitivity as 2-shot Archimedean acquisitions, but require only a single shot. Magn Reson Med 70:1634-1643, 2013. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:1634 / 1643
页数:10
相关论文
共 50 条
  • [1] Deep residual network for highly accelerated fMRI reconstruction using variable density spiral trajectory
    Li, Xuesong
    Cao, Tianle
    Tong, Yan
    Ma, Xiaodong
    Niu, Zhendong
    Guo, Hua
    NEUROCOMPUTING, 2020, 398 : 338 - 346
  • [2] Exploitation of temporal redundancy in compressed sensing reconstruction of fMRI studies with a prior-based algorithm (PICCS)
    Chavarrias, C.
    Abascal, J. F. P. J.
    Montesinos, P.
    Desco, M.
    MEDICAL PHYSICS, 2015, 42 (07) : 3814 - 3821
  • [3] Adapted Variable Density Subsampling for Compressed Sensing
    Ruetz, Simon
    CONSTRUCTIVE APPROXIMATION, 2024,
  • [4] Asymmetric spin-echo (ASE) spiral improves BOLD fMRI in inhomogeneous regions
    Brewer, Kimberly D.
    Rioux, James A.
    D'Arcy, Ryan C. N.
    Bowen, Chris V.
    Beyea, Steven D.
    NMR IN BIOMEDICINE, 2009, 22 (06) : 654 - 662
  • [5] SAR image reconstruction and autofocus by compressed sensing
    Ugur, S.
    Arikan, O.
    DIGITAL SIGNAL PROCESSING, 2012, 22 (06) : 923 - 932
  • [6] Variable-Density Spiral-In/Out Functional Magnetic Resonance Imaging
    Chang, Catie
    Glover, Gary H.
    MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (05) : 1287 - 1296
  • [7] Parallel variable-density spiral imaging using nonlocal total variation reconstruction
    Fang Sheng
    Guo Hua
    CHINESE PHYSICS B, 2014, 23 (05)
  • [8] A Variable Sampling Compressed Sensing Reconstruction Algorithm Based on Texture Information
    Yu Lijun
    Zhong Fei
    Wang Hui
    Zhou Shuai
    2019 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION (ICMA), 2019, : 1632 - 1636
  • [9] Compressed sensing fMRI using gradient-recalled echo and EPI sequences
    Zong, Xiaopeng
    Lee, Juyoung
    Poplawsky, Alexander John
    Kim, Seong-Gi
    Ye, Jong Chul
    NEUROIMAGE, 2014, 92 : 312 - 321
  • [10] Compressed sensing reconstruction of cardiac cine MRI using golden angle spiral trajectories
    Tolouee, Azar
    Alirezaie, Javad
    Babyn, Paul
    JOURNAL OF MAGNETIC RESONANCE, 2015, 260 : 10 - 19