Analysis of Ag(I) Biocide in Water Samples Using Anodic Stripping Voltammetry with a Boron-Doped Diamond Disk Electrode

被引:27
|
作者
Maldonado, Vanessa Y. [1 ,5 ]
Espinoza-Montero, Patricio J. [2 ,3 ]
Rusinek, Cory A. [4 ]
Swain, Greg M. [5 ]
机构
[1] Escuela Politec Nacl, Fac Ingn Quim & Agroind, Ladron Guevara E11-253,POB 17-01-2759, Quito 170525, Ecuador
[2] Pontificia Univ Catolica Ecuador, Escuela Ciencias Quim, Ave 12 Octubre & Roca,POB 17-01-2184, Quito, Ecuador
[3] Escuela Politec Nacl, Dept Ingn Civil & Ambiental, Ladron Guevara E11-253,POB 17-01-2759, Quito, Ecuador
[4] Michigan State Univ, Fraunhofer Ctr Coatings & Diamond Technol, E Lansing, MI 48824 USA
[5] Michigan State Univ, Dept Chem, E Lansing, MI 48824 USA
关键词
CARBON-PASTE ELECTRODE; SOLID-PHASE EXTRACTION; THIN-FILM ELECTRODES; HEAVY-METAL IONS; HYDROGENATED GLASSY-CARBON; SILVER NANOPARTICLES; ELECTROCHEMICAL DETECTION; PYROLYTIC-GRAPHITE; IN-SITU; TOXICITY;
D O I
10.1021/acs.analchem.7b04983
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The electroanalytical performance of a new commercial boron doped diamond disk and a traditional nanocrystalline thin-film electrode were compared for the anodic stripping voltammetric determination of Ag(I). The diamond disk electrode is more flexible than the planar film as the former is compatible with most electrochemical cell designs including those incorporating magnetic stirring. Additionally, mechanical polishing and surface cleaning are simpler to execute. Differential pulse anodic stripping voltammetry (DPASV) was used to detect Ag(I) in standard solutions after optimization of the deposition potential, deposition time and scan rate. The optimized conditions were used to determine the concentration of Ag(I) in a NASA simulated potable water sample and a NIST standard reference solution. The electrochemical results were validated by ICP-OES measurements of the same solutions. The detection figures of merit for the disk electrode were as good or superior to those for the thin-film electrode. Detection limits were <= 5 mu g L-1 (S/N = 3) for a 120 s deposition period, and response variabilities were <5% RSD. The polished disk electrode presented a more limited linear dynamic range presumably because of the reduced surface area available for metal phase formation. The concentrations of Ag(I) in the two water samples, as determined by DPASV, were in good agreement with the concentrations determined by ICP-OES.
引用
收藏
页码:6477 / 6485
页数:9
相关论文
共 50 条
  • [41] Modelling and Optimization of Chlorpheniramine Treatment Using Anodic Oxidation Process on Boron Doped Diamond Electrode
    Askri, Houyem
    Rzig, Boutheina
    Djebali, Kais
    Maamar, Malak
    Bellakhal, Nizar
    CHEMISTRY AFRICA-A JOURNAL OF THE TUNISIAN CHEMICAL SOCIETY, 2024, 7 (07): : 4061 - 4073
  • [42] Application of boron-doped diamond electrodes for the anodic oxidation of pesticide micropollutants in a water treatment process: a critical review
    McBeath, Sean T.
    Wilkinsonb, David P.
    Grahama, Nigel J. D.
    ENVIRONMENTAL SCIENCE-WATER RESEARCH & TECHNOLOGY, 2019, 5 (12) : 2090 - 2107
  • [43] Electrochemical mineralization of uric acid with boron-doped diamond electrode: Factor analysis and degradation mechanism
    Liu, Min
    Dong, Jiayue
    Shen, Yawen
    Zhang, Chunyong
    Fu, Degang
    CHEMOSPHERE, 2019, 236
  • [44] Voltammetric determination of ciprofloxacin in urine samples and its interaction with dsDNA on a cathodically pretreated boron-doped diamond electrode
    Garbellini, Gustavo Stoppa
    Rocha-Filho, Romeu C.
    Fatibello-Filho, Orlando
    ANALYTICAL METHODS, 2015, 7 (08) : 3411 - 3418
  • [45] Dual use of boron-doped diamond electrode in antibiotics-containing water treatment and process control
    Vasilie, Sergiu
    Manea, Florica
    Baciu, Anamaria
    Pop, Aniela
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2018, 117 : 446 - 453
  • [46] Determination of Trace Lead and Cadmium in Water Samples by Anodic Stripping Voltammetry with a NafionIonic Liquid-Coated Bismuth Film Electrode
    Yang, Die
    Wang, Liang
    Chen, Zuliang
    Megharaj, Mallavarapu
    Naidu, Ravi
    ELECTROANALYSIS, 2014, 26 (03) : 639 - 647
  • [47] Investigation of the electrochemical properties of vinblastine on boron-doped diamond electrode treated with anodic pre-treatment in anionic surfactant medium
    Onal, Gunay
    DIAMOND AND RELATED MATERIALS, 2023, 133
  • [48] Determination of Copper in Water by Anodic Stripping Voltammetry Using Cu-DPABA-NA/GCE Modified Electrode
    Stankovic, Dalibor
    Roglic, Goran
    Mutic, Jelena
    Andjelkovic, Ivan
    Markovic, Marijana
    Manojlovic, Dragan
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2011, 6 (11): : 5617 - 5625
  • [49] Sensitive Voltammetric Sensor Based on Boron-Doped Diamond Electrode for Determination of the Chemotherapeutic Drug Methotrexate in Pharmaceutical and Biological Samples
    Selesovska, Renata
    Janikova-Bandzuchova, Lenka
    Chylkova, Jaromira
    ELECTROANALYSIS, 2015, 27 (01) : 42 - 51
  • [50] The cathodically pretreated boron-doped diamond electrode as an environmentally friendly electrochemical tool for the detection and monitoring of mesotrione in food samples
    Mijajlovic, Aleksandar
    Stankovic, Vesna
    Vlahovic, Filip
    Durdic, Sladana
    Manojlovic, Dragan
    Stankovic, Dalibor
    FOOD CHEMISTRY, 2024, 447