Analysis of Ag(I) Biocide in Water Samples Using Anodic Stripping Voltammetry with a Boron-Doped Diamond Disk Electrode

被引:27
|
作者
Maldonado, Vanessa Y. [1 ,5 ]
Espinoza-Montero, Patricio J. [2 ,3 ]
Rusinek, Cory A. [4 ]
Swain, Greg M. [5 ]
机构
[1] Escuela Politec Nacl, Fac Ingn Quim & Agroind, Ladron Guevara E11-253,POB 17-01-2759, Quito 170525, Ecuador
[2] Pontificia Univ Catolica Ecuador, Escuela Ciencias Quim, Ave 12 Octubre & Roca,POB 17-01-2184, Quito, Ecuador
[3] Escuela Politec Nacl, Dept Ingn Civil & Ambiental, Ladron Guevara E11-253,POB 17-01-2759, Quito, Ecuador
[4] Michigan State Univ, Fraunhofer Ctr Coatings & Diamond Technol, E Lansing, MI 48824 USA
[5] Michigan State Univ, Dept Chem, E Lansing, MI 48824 USA
关键词
CARBON-PASTE ELECTRODE; SOLID-PHASE EXTRACTION; THIN-FILM ELECTRODES; HEAVY-METAL IONS; HYDROGENATED GLASSY-CARBON; SILVER NANOPARTICLES; ELECTROCHEMICAL DETECTION; PYROLYTIC-GRAPHITE; IN-SITU; TOXICITY;
D O I
10.1021/acs.analchem.7b04983
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The electroanalytical performance of a new commercial boron doped diamond disk and a traditional nanocrystalline thin-film electrode were compared for the anodic stripping voltammetric determination of Ag(I). The diamond disk electrode is more flexible than the planar film as the former is compatible with most electrochemical cell designs including those incorporating magnetic stirring. Additionally, mechanical polishing and surface cleaning are simpler to execute. Differential pulse anodic stripping voltammetry (DPASV) was used to detect Ag(I) in standard solutions after optimization of the deposition potential, deposition time and scan rate. The optimized conditions were used to determine the concentration of Ag(I) in a NASA simulated potable water sample and a NIST standard reference solution. The electrochemical results were validated by ICP-OES measurements of the same solutions. The detection figures of merit for the disk electrode were as good or superior to those for the thin-film electrode. Detection limits were <= 5 mu g L-1 (S/N = 3) for a 120 s deposition period, and response variabilities were <5% RSD. The polished disk electrode presented a more limited linear dynamic range presumably because of the reduced surface area available for metal phase formation. The concentrations of Ag(I) in the two water samples, as determined by DPASV, were in good agreement with the concentrations determined by ICP-OES.
引用
收藏
页码:6477 / 6485
页数:9
相关论文
共 50 条
  • [21] Anodic oxidation of a simulated effluent containing Reactive Blue 19 on a boron-doped diamond electrode
    Petrucci, Elisabetta
    Montanaro, Daniele
    CHEMICAL ENGINEERING JOURNAL, 2011, 174 (2-3) : 612 - 618
  • [22] Imipramine sensing in pharmaceutical formulations using boron-doped diamond electrode
    Oliveira, Sameque N.
    Ribeiro, Francisco W. P.
    Sousa, Camila P.
    Soares, Janete Eliza S.
    Suffredini, Hugo B.
    Becker, Helena
    de Lima-Neto, Pedro
    Correia, Adriana N.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 788 : 118 - 124
  • [23] Simultaneous determination of nifedipine and atenolol in combined dosage forms using a boron-doped diamond electrode with differential pulse voltammetry
    Scremin, Jessica
    Sartori, Elen Romao
    CANADIAN JOURNAL OF CHEMISTRY, 2018, 96 (01) : 1 - 7
  • [24] Indirect determination of sulfide ions in water samples at trace level by anodic stripping voltammetry using mercury film electrode
    Huang, Deqian
    Xu, Bolei
    Tang, Jie
    Luo, Jian
    Chen, Luhong
    Yang, Lili
    Yang, Zhengbiao
    Bi, Shuping
    ANALYTICAL METHODS, 2010, 2 (02) : 154 - 158
  • [25] A Comparative Analysis of 2-(Thiocyanomethylthio)-Benzothiazole Degradation Using Electro-Fenton and Anodic Oxidation on a Boron-Doped Diamond Electrode
    Vazquez, Armando
    Alvarado, Lucia
    Lazaro, Isabel
    Cruz, Roel
    Nava, Jose Luis
    Rodriguez-Torres, Israel
    INTERNATIONAL JOURNAL OF PHOTOENERGY, 2018, 2018
  • [26] Simultaneous voltammetric detection of benzene, naphthalene and anthracene from water using boron-doped diamond electrode
    Pop, Aniela
    Manea, Florica
    Baciu, Anamaria
    Motoc, Sorina
    SENSING AND BIO-SENSING RESEARCH, 2024, 44
  • [27] The analysis of estrogenic compounds by flow injection analysis with amperometric detection using a boron-doped diamond electrode
    Brocenschi, Ricardo F.
    Rocha-Filho, Romeu C.
    Duran, Boris
    Swain, Greg M.
    TALANTA, 2014, 126 : 12 - 19
  • [28] The Immunosuppressive drug - Rapamycin - Electroanalytical Sensing Using Boron-Doped Diamond electrode
    Stankovic, Dalibor M.
    Katcher, Kurt
    ELECTROCHIMICA ACTA, 2015, 168 : 76 - 81
  • [29] Voltammetric behavior of benzo[a]pyrene at boron-doped diamond electrode: A study of its determination by adsorptive transfer stripping voltammetry based on the enhancement effect of anionic surfactant, sodium dodecylsulfate
    Yardim, Yavuz
    Levent, Abdulkadir
    Keskin, Ertugrul
    Senturk, Zuhre
    TALANTA, 2011, 85 (01) : 441 - 448
  • [30] Sensitive Determination of the Diquat Herbicide in Fresh Food Samples on a Highly Boron-Doped Diamond Electrode
    Melo, Luisa Celia
    De Souza, Djenaine
    de Lima-Neto, Pedro
    Correia, Adriana Nunes
    ELECTROANALYSIS, 2010, 22 (21) : 2502 - 2510