Analysis of Ag(I) Biocide in Water Samples Using Anodic Stripping Voltammetry with a Boron-Doped Diamond Disk Electrode

被引:27
|
作者
Maldonado, Vanessa Y. [1 ,5 ]
Espinoza-Montero, Patricio J. [2 ,3 ]
Rusinek, Cory A. [4 ]
Swain, Greg M. [5 ]
机构
[1] Escuela Politec Nacl, Fac Ingn Quim & Agroind, Ladron Guevara E11-253,POB 17-01-2759, Quito 170525, Ecuador
[2] Pontificia Univ Catolica Ecuador, Escuela Ciencias Quim, Ave 12 Octubre & Roca,POB 17-01-2184, Quito, Ecuador
[3] Escuela Politec Nacl, Dept Ingn Civil & Ambiental, Ladron Guevara E11-253,POB 17-01-2759, Quito, Ecuador
[4] Michigan State Univ, Fraunhofer Ctr Coatings & Diamond Technol, E Lansing, MI 48824 USA
[5] Michigan State Univ, Dept Chem, E Lansing, MI 48824 USA
关键词
CARBON-PASTE ELECTRODE; SOLID-PHASE EXTRACTION; THIN-FILM ELECTRODES; HEAVY-METAL IONS; HYDROGENATED GLASSY-CARBON; SILVER NANOPARTICLES; ELECTROCHEMICAL DETECTION; PYROLYTIC-GRAPHITE; IN-SITU; TOXICITY;
D O I
10.1021/acs.analchem.7b04983
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The electroanalytical performance of a new commercial boron doped diamond disk and a traditional nanocrystalline thin-film electrode were compared for the anodic stripping voltammetric determination of Ag(I). The diamond disk electrode is more flexible than the planar film as the former is compatible with most electrochemical cell designs including those incorporating magnetic stirring. Additionally, mechanical polishing and surface cleaning are simpler to execute. Differential pulse anodic stripping voltammetry (DPASV) was used to detect Ag(I) in standard solutions after optimization of the deposition potential, deposition time and scan rate. The optimized conditions were used to determine the concentration of Ag(I) in a NASA simulated potable water sample and a NIST standard reference solution. The electrochemical results were validated by ICP-OES measurements of the same solutions. The detection figures of merit for the disk electrode were as good or superior to those for the thin-film electrode. Detection limits were <= 5 mu g L-1 (S/N = 3) for a 120 s deposition period, and response variabilities were <5% RSD. The polished disk electrode presented a more limited linear dynamic range presumably because of the reduced surface area available for metal phase formation. The concentrations of Ag(I) in the two water samples, as determined by DPASV, were in good agreement with the concentrations determined by ICP-OES.
引用
收藏
页码:6477 / 6485
页数:9
相关论文
共 50 条
  • [1] Determination of trace levels of Cd(II) in tap water samples by anodic stripping voltammetry with an electrografted boron-doped diamond electrode
    Innuphat, Chalermpol
    Chooto, Pipat
    SCIENCEASIA, 2017, 43 (01): : 33 - 41
  • [2] Determination of trace levels of Pb(II) in tap water by anodic stripping voltammetry with boron-doped diamond electrode
    Chooto, Pipat
    Wararatananurak, Puchong
    Innuphat, Chalermpol
    SCIENCEASIA, 2010, 36 (02): : 150 - 156
  • [3] Determination of Trace Amounts of Uranium by Stripping Voltammetry Using a Boron-Doped Diamond Electrode
    Taguchi, Shigeo
    Surugaya, Naoki
    Kurosawa, Akira
    Hiyama, Toshiaki
    Tanaka, Tatsuhiko
    BUNSEKI KAGAKU, 2010, 59 (11) : 1035 - 1041
  • [4] Determination of Cd2+ by ultrasound-assisted square wave anodic stripping voltammetry with a boron-doped diamond electrode
    Zhang, Tianjin
    Li, Chongying
    Mao, Benjiang
    An, Yan
    IONICS, 2015, 21 (06) : 1761 - 1769
  • [5] Sensitive Detection of Capsaicin by Adsorptive Stripping Voltammetry at a Boron-Doped Diamond Electrode in the Presence of Sodium Dodecylsulfate
    Yardim, Yavuz
    ELECTROANALYSIS, 2011, 23 (10) : 2491 - 2497
  • [6] Electrochemical determination of pterostilbene at a cathodically pretreated boron-doped diamond electrode using square-wave adsorptive anodic stripping voltammetry in cationic surfactant media
    Yigit, Aydin
    Yardim, Yavuz
    Zorer, Ozlem Selcuk
    Senturk, Zuhre
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 231 : 688 - 695
  • [7] The Use of Boron-Doped Diamond Electrode for the Determination of Selected Biocides in Water Samples
    Mielech-Lukasiewicz, Katarzyna
    Starczewska, Barbara
    WATER, 2019, 11 (08)
  • [8] Determination of methiocarb pesticide using differential pulse voltammetry with a boron-doped diamond electrode
    Chylkova, J.
    Tomaskova, M.
    Svancara, I.
    Janikova, L.
    Selesovska, R.
    ANALYTICAL METHODS, 2015, 7 (11) : 4671 - 4677
  • [9] Determination of Nitrophenols in Drinking and River Water by Differential Pulse Voltammetry at Boron-Doped Diamond Film Electrode
    Musilova, Jana
    Barek, Jiri
    Peckova, Karolina
    ELECTROANALYSIS, 2011, 23 (05) : 1236 - 1244
  • [10] Electroanalytical sensing of indigo carmine dye in water samples using a cathodically pretreated boron-doped diamond electrode
    Silva, Tiago Almeida
    Pereira, Gabriel Fernandes
    Fatibello-Filho, Orlando
    Barrios Eguiluz, Katlin Lyon
    Salazar-Banda, Giancarlo Richard
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 769 : 28 - 34