Microfluidic aqueous two phase system for leukocyte concentration from whole blood

被引:101
|
作者
SooHoo, Jeffrey R. [1 ]
Walker, Glenn M.
机构
[1] N Carolina State Univ, Joint Dept Biomed Engn, Raleigh, NC 27695 USA
关键词
Microfluidics; Leukocyte; Aqueous two phase separation; Blood; PEG; Dex; MEMBRANE-SURFACE PROPERTIES; PHASE SYSTEMS; COUNTERCURRENT DISTRIBUTION; FLOW FRACTIONATION; CELLS; PARTITION; LYMPHOCYTES; SEPARATION; POLYMER; DEVICE;
D O I
10.1007/s10544-008-9238-8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Leukocytes from a whole blood sample were concentrated using a microfluidic aqueous two phase system (mu ATPS). Whole blood was simultaneously exposed to polyethylene glycol (PEG) and dextran (Dex) phase streams and cells were partitioned based on their differential affinity for the streams. The laminar flow characteristic of microfluidic devices was used to create zero, one, and two stable interfaces between the polymer streams. Three different patterns of three polymer streams each were evaluated for their effectiveness in concentrating leukocytes: immiscible PEG-PEG-Dex, immiscible Dex-PEG-Dex, and miscible PEG-PBS-Dex. The most effective configuration was the Dex-PEG-Dex stream pattern which on average increased the ratio of leukocytes to erythrocytes by a factor of 9.13 over unconcentrated blood.
引用
收藏
页码:323 / 329
页数:7
相关论文
共 50 条
  • [31] Synthesis of two pH-responsive copolymers in pilot scale and its application in aqueous two-phase system
    Yang, Ting
    Pan, Hongxia
    He, Juan
    Gai, Zhiliang
    Cao, Xuejun
    PROCESS BIOCHEMISTRY, 2019, 79 : 185 - 194
  • [32] An automated two-phase microfluidic system for kinetic analyses and the screening of compound libraries
    Clausell-Tormos, Jenifer
    Griffiths, Andrew D.
    Merten, Christoph A.
    LAB ON A CHIP, 2010, 10 (10) : 1302 - 1307
  • [33] Factors influencing the capillary separation of leukocytes from whole blood in a plastic-based microfluidic chip
    Isoda, T.
    Urushibara, I.
    Umino, K.
    Ishida, Y.
    Sato, H.
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 133 (01) : 213 - 221
  • [34] One-Step Microfluidic Purification of White Blood Cells from Whole Blood for Immunophenotyping
    Kim, Byeongyeon
    Kim, Kyung Hwan
    Chang, Yunjung
    Shin, Suyeon
    Shin, Eui-Cheol
    Choi, Sungyoung
    ANALYTICAL CHEMISTRY, 2019, 91 (20) : 13230 - 13236
  • [35] Aqueous two-phase system to isolate extracellular vesicles from urine for prostate cancer diagnosis
    Shin, Hyunwoo
    Park, Yong Hyun
    Kim, Yong-Goo
    Lee, Ji Youl
    Park, Jaesung
    PLOS ONE, 2018, 13 (03):
  • [36] A Novel Optical Assay System for Bilirubin Concentration Measurement in Whole Blood
    Ndabakuranye, Jean Pierre
    Rajapaksa, Anushi E.
    Burchall, Genia
    Li, Shiqiang
    Prawer, Steven
    Ahnood, Arman
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2022, 69 (02) : 983 - 990
  • [37] Automatically Controlled Microfluidic System for Continuous Separation of Rare Bacteria from Blood
    Yoon, Taehee
    Moon, Hui-Sung
    Song, Jae-Woo
    Hyun, Kyung-A
    Jung, Hyo-Il
    CYTOMETRY PART A, 2019, 95 (11) : 1135 - 1144
  • [38] An aqueous two-phase system as a strategy for serum albumin depletion
    Oseas da Silva, Marcelo Anselmo
    Zezzi Arruda, Marco Aurelio
    TALANTA, 2009, 77 (03) : 985 - 990
  • [39] Inertial microfluidic cube for automatic and fast extraction of white blood cells from whole blood
    Zhu, Shu
    Wu, Dan
    Han, Yu
    Wang, Cailian
    Xiang, Nan
    Ni, Zhonghua
    LAB ON A CHIP, 2020, 20 (02) : 244 - 252
  • [40] Wicking microfluidic approach to separate blood plasma from whole blood to facilitate downstream assays
    Bandara, Gayan C.
    Unitan, Linus J.
    Kremer, Matthew H.
    Shellhammer, Owen T.
    Bracha, Shay
    Remcho, Vincent T.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (17) : 4511 - 4520