Agreement of Mammographic Measures of Volumetric Breast Density to MRI
被引:31
作者:
Wang, Jeff
[1
]
Azziz, Ania
[1
]
Fan, Bo
[1
]
Malkov, Serghei
[1
]
Klifa, Catherine
[2
]
Newitt, David
[1
]
Yitta, Silaja
[1
]
Hylton, Nola
[1
]
Kerlikowske, Karla
[3
,4
]
Shepherd, John A.
[1
]
机构:
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94143 USA
[2] Synarc Inc, Newark, CA USA
[3] Univ Calif San Francisco, Dept Med, San Francisco, CA 94143 USA
[4] Univ Calif San Francisco, Dept Epidemiol Biostat, San Francisco, CA 94143 USA
来源:
PLOS ONE
|
2013年
/
8卷
/
12期
关键词:
CANCER RISK;
SCREENING MAMMOGRAPHY;
TISSUE COMPOSITION;
BODY-COMPOSITION;
TAMOXIFEN;
WOMEN;
MODEL;
REDUCTION;
PATTERNS;
INDEX;
D O I:
10.1371/journal.pone.0081653
中图分类号:
O [数理科学和化学];
P [天文学、地球科学];
Q [生物科学];
N [自然科学总论];
学科分类号:
07 ;
0710 ;
09 ;
摘要:
Background: Clinical scores of mammographic breast density are highly subjective. Automated technologies for mammography exist to quantify breast density objectively, but the technique that most accurately measures the quantity of breast fibroglandular tissue is not known. Purpose: To compare the agreement of three automated mammographic techniques for measuring volumetric breast density with a quantitative volumetric MRI-based technique in a screening population. Materials and Methods: Women were selected from the UCSF Medical Center screening population that had received both a screening MRI and digital mammogram within one year of each other, had Breast Imaging Reporting and Data System (BI-RADS) assessments of normal or benign finding, and no history of breast cancer or surgery. Agreement was assessed of three mammographic techniques (Single-energy X-ray Absorptiometry [SXA], Quantra, and Volpara) with MRI for percent fibroglandular tissue volume, absolute fibroglandular tissue volume, and total breast volume. Results: Among 99 women, the automated mammographic density techniques were correlated with MRI measures with R-2 values ranging from 0.40 (log fibroglandular volume) to 0.91 (total breast volume). Substantial agreement measured by kappa statistic was found between all percent fibroglandular tissue measures (0.72 to 0.63), but only moderate agreement for log fibroglandular volumes. The kappa statistics for all percent density measures were highest in the comparisons of the SXA and MRI results. The largest error source between MRI and the mammography techniques was found to be differences in measures of total breast volume. Conclusion: Automated volumetric fibroglandular tissue measures from screening digital mammograms were in substantial agreement with MRI and if associated with breast cancer could be used in clinical practice to enhance risk assessment and prevention.