High-throughput metabolic genotoxicity screening with a fluidic microwell chip and electrochemiluminescence

被引:25
作者
Wasalathanthri, Dhanuka P. [1 ]
Malla, Spundana [1 ]
Bist, Itti [1 ]
Tang, Chi K. [1 ]
Faria, Ronaldo C. [1 ,2 ]
Rusling, James F. [1 ,3 ,4 ]
机构
[1] Univ Connecticut, Dept Chem, Storrs, CT 06269 USA
[2] Univ Fed Sao Carlos, Dept Quim, BR-13560 Sao Carlos, SP, Brazil
[3] Natl Univ Ireland, Sch Chem, Galway, Ireland
[4] Univ Connecticut, Ctr Hlth, Dept Cell Biol, Farmington, CT 06032 USA
基金
巴西圣保罗研究基金会;
关键词
REACTIVE METABOLITES; DNA-DAMAGE; BIOCOLLOID REACTORS; CYTOCHROME-P450; TOXICITY; INHIBITORS; ARRAYS; BENZO(A)PYRENE; COMMON;
D O I
10.1039/c3lc50698c
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A high throughput electrochemiluminescent (ECL) chip was fabricated and integrated into a fluidic system for screening toxicity-related chemistry of drug and pollutant metabolites. The chip base is conductive pyrolytic graphite onto which are printed 64 microwells capable of holding one-mu L droplets. Films combining DNA, metabolic enzymes and an ECL-generating ruthenium metallopolymer ((RuPVP)-P-II) are fabricated in these microwells. The system runs metabolic enzyme reactions, and subsequently detects DNA damage caused by reactive metabolites. The performance of the chip was tested by measuring DNA damage caused by metabolites of the well-known procarcinogen benzo[a]pyrene (B[a]P). Liver microsomes and cytochrome P450 (cyt P450) enzymes were used with and without epoxide hydrolase (EH), a conjugative enzyme required for multi-enzyme bioactivation of B[a]P. DNA adduct formation was confirmed by determining specific DNA-metabolite adducts using similar films of DNA/enzyme on magnetic bead biocolloid reactors, hydrolyzing the DNA, and analyzing by capillary liquid chromatography-mass spectrometry (CapLC-MS/MS). The fluidic chip was also used to measure IC50-values of inhibitors of cyt P450s. All results show good correlation with reported enzyme activity and inhibition assays.
引用
收藏
页码:4554 / 4562
页数:9
相关论文
共 60 条
[1]   Enzyme-DNA biocolloids for DNA adduct and reactive metabolite detection by chromatography-mass Spectrometry [J].
Bajrami, Besnik ;
Hvastkovs, Eli G. ;
Jensen, Gary C. ;
Schenkman, John B. ;
Rusling, James F. .
ANALYTICAL CHEMISTRY, 2008, 80 (04) :922-932
[2]   Rapid LC-MS Drug Metabolite Profiling Using Microsomal Enzyme Bioreactors in a Parallel Processing Format [J].
Bajrami, Besnik ;
Zhao, Linlin ;
Schenkman, John B. ;
Rusling, James F. .
ANALYTICAL CHEMISTRY, 2009, 81 (24) :9921-9929
[3]  
Bajrami Besnik, 2008, Drug Metab Lett, V2, P158, DOI 10.2174/187231208785425854
[4]   OXIDATION OF BENZO[A]PYRENE BY RECOMBINANT HUMAN CYTOCHROME-P450 ENZYMES [J].
BAUER, E ;
GUO, ZY ;
UENG, YF ;
BELL, LC ;
ZELDIN, D ;
GUENGERICH, FP .
CHEMICAL RESEARCH IN TOXICOLOGY, 1995, 8 (01) :136-142
[5]   High-performance liquid chromatography electrospray ionization tandem mass spectrometry for the detection and quantitation of benzo[a]pyrene-DNA adducts [J].
Beland, FA ;
Churchwell, MI ;
Von Tungeln, LS ;
Chen, SJ ;
Fu, PP ;
Culp, SJ ;
Schoket, B ;
Gyorffy, E ;
Minárovits, J ;
Poirier, MC ;
Bowman, ED ;
Weston, A ;
Doerge, DR .
CHEMICAL RESEARCH IN TOXICOLOGY, 2005, 18 (08) :1306-1315
[6]   Mechanisms of Chemical Carcinogenicity and Mutagenicity: A Review with Implications for Predictive Toxicology [J].
Benigni, Romualdo ;
Bossa, Cecilia .
CHEMICAL REVIEWS, 2011, 111 (04) :2507-2536
[7]   Nanostructured materials for electrochemiluminescence (ECL)-based detection methods: Recent advances and future perspectives [J].
Bertoncello, Paolo ;
Forster, Robert J. .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (11) :3191-3200
[8]  
Bourrie M, 1996, J PHARMACOL EXP THER, V277, P321
[9]   An update on in vitro test methods in human hepatic drug biotransformation research: pros and cons [J].
Brandon, EFA ;
Raap, CD ;
Meijerman, I ;
Beijnen, JH ;
Schellens, JHM .
TOXICOLOGY AND APPLIED PHARMACOLOGY, 2003, 189 (03) :233-246
[10]  
Chun YJ, 2001, DRUG METAB DISPOS, V29, P389