Appearances of pulmonary focal lesions at 0.5-mm slice thickness computed tomography: comparison with 1-mm slice thickness computed tomography

被引:2
|
作者
Nambu, Atsushi [1 ]
Kato, Satoshi [1 ]
Araki, Tsutomu [1 ]
Saito, Akitoshi [1 ]
机构
[1] Univ Yamanashi, Dept Radiol, Chuo, Yamanashi 4093898, Japan
关键词
Thin-section CT; High-resolution CT; Multi-detector row CT; Lung carcinoma; Ground-glass opacity; HIGH-RESOLUTION CT; THIN-SECTION CT; HELICAL CT; LUNG; RECONSTRUCTION; ADENOCARCINOMA;
D O I
10.1016/j.clinimag.2008.06.027
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aim: This study aimed to evaluate the validity of 0.5-mm thin-section computed tomography (CT) for the assessment of pulmonary nodular lesion in comparison with 1-mm CT. Materials and Methods: A total of 38 focal lesions from 30 patients, which were scanned with 0.5- and 1.0-mm collimation, were evaluated regarding the extent of ground-glass opacity (GGO) and well-defined margin, and the presence of pleural indentation, spicula, and internal air density. The frequency of each finding was statistically compared between 0.5- and 1-mm CT using the McNemar test. Results: No statistically significant difference was observed between 0.5- and 1-mm CT for each finding. Conclusion: The use of 0.5-mm CT is not justified if the original collimation of multi-detector row CT is near 1 mm. (C) 2009 Elsevier Inc. All rights reserved.
引用
收藏
页码:11 / 14
页数:4
相关论文
共 50 条
  • [31] Correlation between Aortic Wall Thickness and Coronary Artery Disease by 64 Slice Multidetector Computed Tomography
    Shakeri, Abolhassan
    Quran, Farnaz Hafez
    Javadrashid, Reza
    Abdekarimi, Mohammad Hossein
    Ghojazadeh, Morteza
    Fakhree, Mohammad Bassir Abolghassemi
    JOURNAL OF CARDIOVASCULAR AND THORACIC RESEARCH, 2013, 5 (03) : 91 - 95
  • [32] Impact of slice thickness on clinical utility of automated Alberta Stroke Program Early Computed Tomography Scores
    Ulf Neuberger
    Simon Nagel
    Johannes Pfaff
    Peter Arthur Ringleb
    Christian Herweh
    Martin Bendszus
    Markus Alfred Möhlenbruch
    Philipp Kickingereder
    European Radiology, 2020, 30 : 3137 - 3145
  • [33] Computed tomography liver volumetry in living donor liver transplantation: influence of the slice thickness on the volume calculation
    Fatima, Tooba
    Rafique, Muhammad Salman
    Kundi, Sana
    Malik, Tahir
    Ijaz, Faryal
    Zulfiqar, Sahar
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2025, 75 (04) : 564 - 568
  • [34] Impact of slice thickness on clinical utility of automated Alberta Stroke Program Early Computed Tomography Scores
    Neuberger, Ulf
    Nagel, Simon
    Pfaff, Johannes
    Ringleb, Peter Arthur
    Herweh, Christian
    Bendszus, Martin
    Moehlenbruch, Markus Alfred
    Kickingereder, Philipp
    EUROPEAN RADIOLOGY, 2020, 30 (06) : 3137 - 3145
  • [35] The accuracy and optimal slice thickness of multislice helical computed tomography for right and left ventricular volume measurement
    崔炜
    近藤武
    安野泰史Department of Radiological Technology
    School of Health Sciences Fujita Health University
    Toyoake 470-1192
    Japan
    郭玉印
    佐藤贵久
    皿井正羲
    篠崎仁史
    柿澤聡士
    杉浦厚司
    大岛慶太
    片田和廣
    菱田仁
    中华医学杂志(英文版), 2004, (09) : 3 - 7
  • [36] The accuracy and optimal slice thickness of multislice helical computed tomography for right and left ventricular volume measurement
    崔炜近藤武安野泰史Department of Radiological Technology School of Health Sciences Fujita Health University Toyoake Japan郭玉印佐藤贵久皿井正羲篠崎仁史柿澤聡士杉浦厚司大岛慶太片田和廣菱田仁
    Chinese Medical Journal, 2004, (09)
  • [37] PULMONARY NODULES IN SPIRAL VOLUMETRIC AND SINGLE SLICE COMPUTED-TOMOGRAPHY
    FRIESE, SA
    RIEBER, A
    FLEITER, T
    BRAMBS, HJ
    CLAUSSEN, CD
    EUROPEAN JOURNAL OF RADIOLOGY, 1994, 18 (01) : 48 - 51
  • [38] The accuracy and optimal slice thickness of multislice helical computed tomography for right and left ventricular volume measurement
    Cui, W
    Kondo, T
    Anno, H
    Guo, YY
    Sato, T
    Sarai, M
    Shinozaki, H
    Kakizawa, S
    Sugiura, K
    Oshima, K
    Katada, K
    Hishida, H
    CHINESE MEDICAL JOURNAL, 2004, 117 (09) : 1283 - 1287
  • [39] Semiautomated Renal Cortex Volumetry in Multislice Computed Tomography: Effect of Slice Thickness and Iterative Reconstruction Algorithms
    Houbois, Christian
    Haneder, Stefan
    Merkt, Martin
    Holz, Jasmin A.
    Morelli, John
    Kiel, Alexandra
    Doerner, Jonas
    Maintz, David
    Puesken, Michael
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2020, 44 (02) : 236 - 241
  • [40] Comparison of Different Slice Thicknesses in Computed Tomography for Labyrinthine Fistula Evaluation
    Du, Qiang
    Hong, Rujian
    Pan, Yucheng
    Liu, Junhua
    Liang, Qin
    Wang, Kaishi
    Han, Zhao
    Wang, Wuqing
    ORL-JOURNAL FOR OTO-RHINO-LARYNGOLOGY HEAD AND NECK SURGERY, 2020, 82 (01): : 8 - 14