Incidences, Predictors, and Clinical Outcomes of Acute and Late Stent Malapposition Detected by Optical Coherence Tomography After Drug-Eluting Stent Implantation

被引:120
作者
Im, Eui [1 ]
Kim, Byeong-Keuk [1 ]
Ko, Young-Guk [1 ]
Shin, Dong-Ho [1 ]
Kim, Jung-Sun [1 ]
Choi, Donghoon [1 ]
Jang, Yangsoo [1 ,2 ]
Hong, Myeong-Ki [1 ,2 ]
机构
[1] Yonsei Univ, Coll Med, Severance Cardiovasc Hosp, Div Cardiol, Seoul 120752, South Korea
[2] Yonsei Univ, Coll Med, Severance Biomed Sci Inst, Seoul 120752, South Korea
关键词
INTRAVASCULAR ULTRASOUND ANALYSIS; FOLLOW-UP; COMERS TRIAL; MYOCARDIAL-INFARCTION; APPOSITION; INTERVENTION; THROMBOSIS; COVERAGE; RESOLUTE; PROLAPSE;
D O I
10.1161/CIRCINTERVENTIONS.113.000797
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-We investigated the incidences, predictors, and clinical outcomes of acute and late stent malapposition detected by optical coherence tomography (OCT) after drug-eluting stent implantation. Methods and Results-We analyzed the OCT images from 351 patients with 356 lesions who received poststent and followup OCT examinations. Acute stent malapposition was observed in 62% of lesions. Approximately half of the acute stent malappositions were located within the edges of the stents. Severe diameter stenosis, calcified lesions, and long stents were independent predictors of acute stent malapposition. Follow-up OCT examinations were performed 175±60 days after drug-eluting stent implantation. Thirty-one percent of lesions with acute stent malapposition remained malapposed (late-persistent stent malapposition) and were typically (72%) located within the edges of the stent. The location within the stent edges and the volume of acute stent malapposition were independent predictors of late-persistent stent malapposition. Acute stent malapposition with a volume >2.56 mm3 differentiated late-persistent stent malapposition from resolved acute stent malapposition. Late-acquired stent malapposition was detected in 15% of all lesions and was usually (61%) located within the stent body. Late-acquired stent malapposition was more frequently associated with plaque/thrombus prolapse on poststent OCT images (70% versus 42%; P<0.001). Clinical events, including cardiovascular death, nonfatal myocardial infarction, and stent thrombosis, did not occur in patients with late stent malapposition during the follow-up period of 28.6±10.3 months after drug-eluting stent implantation. Conclusions-Acute, late-persistent, and late-acquired stent malapposition had relatively high incidences but different predictors. The clinical outcome of stent malapposition was favorable. © 2014 American Heart Association, Inc.
引用
收藏
页码:88 / 96
页数:9
相关论文
共 26 条
[1]   Quantitative analysis of intracoronary optical coherence tomography measurements of stent strut apposition and tissue coverage [J].
Barlis, Peter ;
Dimopoulos, Konstantinos ;
Tanigawa, Jun ;
Dzielicka, Ewa ;
Ferrante, Giuseppe ;
Del Furia, Francesca ;
Di Mario, Carlo .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2010, 141 (02) :151-156
[2]   Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation [J].
Cook, Stephane ;
Wenaweser, Peter ;
Togni, Mario ;
Billinger, Michael ;
Morger, Cyrill ;
Seiler, Christian ;
Vogel, Rolf ;
Hess, Otto ;
Meier, Bernhard ;
Windecker, Stephan .
CIRCULATION, 2007, 115 (18) :2426-2434
[3]   An optical coherence tomography study of two new generation stents with biodegradable polymer carrier, eluting paclitaxel vs. biolimus-A9 [J].
Davlouros, Periklis A. ;
Mavronasiou, Eleni ;
Xanthopoulou, Ioanna ;
Karantalis, Vasileios ;
Tsigkas, Grigorios ;
Hahalis, George ;
Alexopoulos, Dimitrios .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2012, 157 (03) :341-346
[4]   Incidence, Mechanisms, Predictors, and Clinical Impact of Acute and Late Stent Malapposition After Primary Intervention in Patients With Acute Myocardial Infarction An Intravascular Ultrasound Substudy of the Harmonizing Outcomes With Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) Trial [J].
Guo, Ning ;
Maehara, Akiko ;
Mintz, Gary S. ;
He, Yong ;
Xu, Kai ;
Wu, Xiaofan ;
Lansky, Alexandra J. ;
Witzenbichler, Bernhard ;
Guagliumi, Giulio ;
Brodie, Bruce ;
Kellett, Mirle A., Jr. ;
Dressler, Ovidiu ;
Parise, Helen ;
Mehran, Roxana ;
Stone, Gregg W. .
CIRCULATION, 2010, 122 (11) :1077-1084
[5]   Vascular Tissue Reaction to Acute Malapposition in Human Coronary Arteries Sequential Assessment With Optical Coherence Tomography [J].
Gutierrez-Chico, Juan Luis ;
Wykrzykowska, Joanna ;
Nueesch, Eveline ;
van Geuns, Robert Jan ;
Koch, Karel T. ;
Koolen, Jacques J. ;
di Mario, Carlo ;
Windecker, Stephan ;
van Es, Gerrit-Anne ;
Gobbens, Pierre ;
Jueni, Peter ;
Regar, Evelyn ;
Serruys, Patrick W. .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (01) :20-U81
[6]   Tissue coverage of a hydrophilic polymer-coated zotarolimus-eluting stent vs. a fluoropolymer-coated everolimus-eluting stent at 13-month follow-up: an optical coherence tomography substudy from the RESOLUTE All Comers trial [J].
Gutierrez-Chico, Juan Luis ;
van Geuns, Robert Jan ;
Regar, Evelyn ;
van der Giessen, Willem J. ;
Kelbaek, Henning ;
Saunamaki, Kari ;
Escaned, Javier ;
Gonzalo, Nieves ;
di Mario, Carlo ;
Borgia, Francesco ;
Nueesch, Eveline ;
Garcia-Garcia, Hector M. ;
Silber, Sigmund ;
Windecker, Stephan ;
Serruys, Patrick W. .
EUROPEAN HEART JOURNAL, 2011, 32 (19) :2454-2463
[7]   Late stent malapposition risk is higher after drug-eluting stent compared with bare-metal stent implantation and associates with late stent thrombosis [J].
Hassan, Ayman K. M. ;
Bergheanu, Sandrin C. ;
Stijnen, Theo ;
van der Hoeven, Bas L. ;
Snoep, Jaapjan D. ;
Plevier, Josepha W. M. ;
Schalij, Martin J. ;
Jukema, J. Wouter .
EUROPEAN HEART JOURNAL, 2010, 31 (10) :1172-1180
[8]   Effect of Intensive Statin Therapy on Regression of Coronary Atherosclerosis in Patients With Acute Coronary Syndrome A Multicenter Randomized Trial Evaluated by Volumetric Intravascular Ultrasound Using Pitavastatin Versus Atorvastatin (JAPAN-ACS [Japan Assessment of Pitavastatin and Atorvastatin in Acute Coronary Syndrome] Study) [J].
Hiro, Takafumi ;
Kimura, Takeshi ;
Morimoto, Takeshi ;
Miyauchi, Katsumi ;
Nakagawa, Yoshihisa ;
Yamagishi, Masakazu ;
Ozaki, Yukio ;
Kimura, Kazuo ;
Saito, Satoshi ;
Yamaguchi, Tetsu ;
Daida, Hiroyuki ;
Matsuzaki, Masunori .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 54 (04) :293-302
[9]   Late stent malapposition after drug-eluting stent implantation - An intravascular ultrasound analysis with long-term follow-up [J].
Hong, MK ;
Mintz, GS ;
Lee, CW ;
Park, DW ;
Park, KM ;
Lee, BK ;
Kim, YH ;
Song, JM ;
Han, KH ;
Kang, DH ;
Cheong, SS ;
Song, JK ;
Kim, JJ ;
Park, SW ;
Park, SJ .
CIRCULATION, 2006, 113 (03) :414-419
[10]   Impact of late drug-eluting stent malapposition on 3-year clinical events [J].
Hong, Myeong-Ki ;
Mintz, Gary S. ;
Lee, Cheol Whan ;
Park, Duk-Woo ;
Lee, Seung-Whan ;
Kim, Young-Hak ;
Kang, Duk-Hyun ;
Cheong, Sang-Sig ;
Song, Jae-Kwan ;
Kim, Jae-Joong ;
Park, Seong-Wook ;
Park, Seung-Jung .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (15) :1515-1516