A new point-of-care portable immunosensor for non-invasive assessment of oro-ileal transit time by oral fluid tauroursodeoxycholate measurement after its oral load

被引:0
作者
Simoni, Patrizia [1 ]
Magliulo, Maria [2 ,3 ]
Mirasoli, Mara [2 ,3 ]
Vestito, Amanda [1 ]
Festi, Davide [1 ]
Roda, Giulia [1 ]
Colecchia, Antonio [1 ]
Roda, Aldo [2 ,3 ]
机构
[1] Univ Bologna, Dept Med & Surg Sci, I-40138 Bologna, Italy
[2] Univ Bologna, Dept Chem G Ciamician, I-40126 Bologna, Italy
[3] Consorzio Interuniv, Ist Nazl Biostrutture & Biosistemi, I-00136 Rome, Italy
关键词
Oro-ileal transit time; Tauroursodeoxycholic acid; Oral fluid; Chemiluminescence immunoassay; Point-of-care testing; BREATH TEST; GASTROINTESTINAL MOTILITY; SULFAPYRIDINE APPEARANCE; GALLSTONE PATIENTS; SERUM ALBUMIN; BILE-ACIDS; SCINTIGRAPHY; VALIDATION; HYDROGEN; SALIVA;
D O I
10.1016/j.jpba.2013.03.013
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A non-invasive test for oro-ileal transit time (OITT) evaluation was developed, based on the measurement of tauroursodeoxycholic acid (TUDCA) oral fluid concentration profile after its oral administration. Exploiting the fact that TUDCA is actively absorbed only in the ileum, OITT is measured as the time corresponding to TUDCA maximum oral fluid concentration (t(max)). To measure oral fluid TUDCA concentration in a point-of-care setting, an ultrasensitive portable immunosensor was developed, based on a competitive chemiluminescent enzyme immunoassay (CL-EIA), using immobilized anti-TUDCA antibody and an ursodeoxycholic acid (UDCA)-peroxidase conjugate as tracer, detected by enhanced chemiluminescence employing a portable charge-coupled device (CCD)-based device. The test was validated in 24 healthy subjects before and after treatment with Loperamide, a drug that increases OITT. The developed CL-EIA was accurate and precise, with a LLOQ of 50 pmol L-1. The measured OITT for healthy subjects (291 +/- 50 min) was fairly well correlated with OITT values obtained by measuring TUDCA in serum (r = 0.89). An increased OITT was observed in all the studied subjects after Loperamide treatment. The CL immunosensor can be employed directly in gastroenterology and paediatric units and it can thus represent a new non-invasive simple test for OITT evaluation in a point-of-care setting, with improved. diagnostic utility. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 30 条
[1]  
ARGENYI EE, 1995, AM J GASTROENTEROL, V90, P938
[2]  
Azzaroli F, 1999, AM J GASTROENTEROL, V94, P2453
[3]   Ultrasensitive quantitative determination of paraquat: Application to river, ground, and drinking water analysis in an agricultural area [J].
Bacigalupo, MA ;
Meroni, G ;
Mirasoli, M ;
Parisi, D ;
Longhi, R .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2005, 53 (02) :216-219
[4]   Ursodeoxycholic acid improves gastrointestinal motility defects in gallstone patients [J].
Colecchia, A. ;
Mazzella, G. ;
Sandri, L. ;
Azzaroli, F. ;
Magliulo, M. ;
Simoni, P. ;
Bacchi-Reggiani, M. L. ;
Roda, E. ;
Festi, D. .
WORLD JOURNAL OF GASTROENTEROLOGY, 2006, 12 (33) :5336-5343
[5]   OROCECAL TRANSIT-TIME IN HUMANS ASSESSED BY SULFAPYRIDINE APPEARANCE IN SALIVA AFTER SULFASALAZINE INTAKE [J].
DHOTE, R ;
BERGMANN, JF ;
LEGLISE, P ;
CHASSANY, O ;
ELKHARRAT, D ;
CONORT, O ;
CAULIN, C .
CLINICAL PHARMACOLOGY & THERAPEUTICS, 1995, 57 (04) :461-470
[6]   EFFECT OF CISAPRIDE ON THE GASTROINTESTINAL TRANSIT OF A SOLID MEAL IN NORMAL HUMAN-SUBJECTS [J].
EDWARDS, CA ;
HOLDEN, S ;
BROWN, C ;
READ, NW .
GUT, 1987, 28 (01) :13-16
[7]  
ERLANGER BF, 1957, J BIOL CHEM, V228, P713
[8]  
Geypens B, 1999, J NUCL MED, V40, P1451
[9]  
Hofmann A F, 1976, Adv Intern Med, V21, P501
[10]   SULFAPYRIDINE APPEARANCE IN PLASMA AFTER SALICYLAZOSULFAPYRIDINE - ANOTHER SIMPLE MEASURE OF INTESTINAL TRANSIT [J].
KELLOW, JE ;
BORODY, TJ ;
PHILLIPS, SF ;
HADDAD, AC ;
BROWN, ML .
GASTROENTEROLOGY, 1986, 91 (02) :396-400