Efficiency of MS2 phage and Qβ phage removal by membrane filtration in water treatment: Applicability of real-time RT-PCR method

被引:77
作者
Langlet, Jeremie [1 ]
Ogorzaly, Leslie [1 ]
Schrotter, Jean-Christophe [2 ]
Machinal, Claire [2 ]
Gaboriaud, Fabien [3 ]
Duval, Jerome F. L. [4 ]
Gantzer, Christophe [1 ]
机构
[1] Nancy Univ, CNRS, LCPME, F-54000 Nancy, France
[2] Water Res Ctr, F-78603 Maisons Laffitte, France
[3] Nancy Univ, CNRS, LCPME, F-54600 Villers Les Nancy, France
[4] Nancy Univ, CNRS, LEM, F-54501 Vandoeuvre Les Nancy, France
关键词
MS2; phage; Q beta phage; Filtration; Virus removal; Real-time RT-PCR; DRINKING-WATER; VIRUS REMOVAL; WASTE-WATER; BACTERIOPHAGE-MS2; MICROFILTRATION; AGGREGATION; TECHNOLOGY; PARAMETERS; PARTICLES; IMPACT;
D O I
10.1016/j.memsci.2008.09.044
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
MS2 phage is currently used as a surrogate to evaluate pathogenic virus removal efficiency by filtration membrane during water treatment. Phage removal is commonly defined upon comparing number of infectious units in permeate with that in feed solution by PFU method. This method may lead to overestimation of the virus removal because of possible occurrence of viruses aggregation. In this study, we report the removal efficiencies of various conventional membranes used in water treatment technology, with respect to suspensions of MS2 and Q beta bacteriophages. These phages - known to exhibit distinct interfacial characteristics in terms of electrostatic charge and degree of hydrophobicity were used in conditions where viral particle aggregation is negligible. Under such conditions, the feasibility of fast, easy to handle, molecular biology method, i.e. real-time RT-PCR, for measuring virus removal rates is clearly addressed. Comparison of the results provided by this method with those obtained via more traditional procedure is given. On the basis of the filtration results, it is shown that W phages are eliminated to a lower extent than MS2 phages, this being the case for all membranes considered here. Accordingly, the analysis questions the choice of MS2 phage as the best surrogate classically used for characterizing membrane virus removal propensity in worst possible conditions. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:111 / 116
页数:6
相关论文
共 22 条
[1]  
[Anonymous], 1995, 107051 ISO
[2]   Removal of coliphages in secondary effluent by microfiltration - mechanisms of removal and impact of operating parameters [J].
Farahbakhsh, K ;
Smith, DW .
WATER RESEARCH, 2004, 38 (03) :585-592
[3]   The effect of coagulation with MF/UF membrane filtration for the removal of virus in drinking water [J].
Fiksdal, Liv ;
Leiknes, TorOve .
JOURNAL OF MEMBRANE SCIENCE, 2006, 279 (1-2) :364-371
[4]   Presence of viral genomes in mineral water: A sufficient condition to assume infectious risk? [J].
Gassilloud, B ;
Schwartzbrod, L ;
Gantzer, C .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2003, 69 (07) :3965-3969
[5]   Removal of viruses by microfiltration membranes at different solution environments [J].
Herath, G ;
Yamamoto, K ;
Urase, T .
WATER SCIENCE AND TECHNOLOGY, 1999, 40 (4-5) :331-338
[6]   Removal of MS2 bacteriophage using membrane technologies [J].
Hu, JY ;
Ong, SL ;
Song, LF ;
Feng, YY ;
Liu, WT ;
Tan, TW ;
Lee, LY ;
Ng, WJ .
WATER SCIENCE AND TECHNOLOGY, 2003, 47 (12) :163-168
[7]  
JACANGELO JG, 1995, J AM WATER WORKS ASS, V87, P107
[8]   Role of membrane technology in drinking water treatment in the United States [J].
Jacangelo, JG ;
Trussell, RR ;
Watson, M .
DESALINATION, 1997, 113 (2-3) :119-127
[9]   Effects of pH on plaque forming unit counts and aggregation of MS2 bacteriophage [J].
Langlet, J. ;
Gaboriaud, F. ;
Gantzer, C. .
JOURNAL OF APPLIED MICROBIOLOGY, 2007, 103 (05) :1632-1638
[10]   Aggregation and surface properties of F-specific RNA phages: Implication for membrane filtration processes [J].
Langlet, Jeremie ;
Gaboriaud, Fabien ;
Duval, Jerome F. L. ;
Gantzer, Christophe .
WATER RESEARCH, 2008, 42 (10-11) :2769-2777