Preparation of Pt/polypyrrole-ferrocene hydrogen peroxide sensitive electrode for the use as a biosensor

被引:13
作者
Arslan, F [1 ]
Yasar, A
Kiliç, E
机构
[1] Gazi Univ, TR-06500 Ankara, Turkey
[2] Ankara Univ, TR-06100 Ankara, Turkey
关键词
polypyrrole; hydrogen peroxide; ferrocene;
D O I
10.1134/S1023193506020042
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A polypyrrole electrode with ferrocene mediator is prepared and its sensitivity to hydrogen peroxide is investigated. The polypyrrole is deposited upon a 0.5 cm(2) Pt plate by the polymerization of pyrrole by scanning the electrode potential between 0.0 and 0.9 V at a scan rate of 50 mV/s. The platinum/polypyrrole-ferrocene (Pt/PPy-Fc) electrode is prepared by adding ferrocene to the coverage medium. The electrode's sensitivity to hydrogen peroxide is investigated at room temperature using 0.025 M phosphate buffer at pH 7. The working potential is 0.7 V, the concentrations of pyrrole and ferrocene are 0.2 M and 10 mM. Polypyrrole was coated on the electrode surface within 26 cycles.
引用
收藏
页码:137 / 140
页数:4
相关论文
共 17 条
[1]   Xanthine and hypoxanthine sensors based on xanthine oxidase immobilized in poly(mercapto-p-benzoquinone) film [J].
Arai, G ;
Takahashi, S ;
Yasumori, I .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1996, 410 (02) :173-179
[2]   Determination of hydrogen peroxide in disinfectant solutions using a biosensor with two antagonist enzymes [J].
Campanella, L ;
Favero, G ;
Giancola, D ;
Tomassetti, M .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 32 (4-5) :737-751
[3]   Mediated biosensors [J].
Chaubey, A ;
Malhotra, BD .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (6-7) :441-456
[4]   Immobilization of beef liver catalase on eggshell membrane for fabrication of hydrogen peroxide biosensor [J].
Choi, MMF ;
Yiu, TP .
ENZYME AND MICROBIAL TECHNOLOGY, 2004, 34 (01) :41-47
[5]   New fructose biosensors utilizing a polypyrrole film and D-fructose 5-dehydrogenase immobilized by different processes [J].
Garcia, CAB ;
Neto, GD ;
Kubota, LT .
ANALYTICA CHIMICA ACTA, 1998, 374 (2-3) :201-208
[6]   Application of conducting polymers to biosensors [J].
Gerard, M ;
Chaubey, A ;
Malhotra, BD .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (05) :345-359
[7]  
Gros P, 2000, ELECTROCHIM ACTA, V46, P643
[8]   Disposable creatinine sensor based on thick-film hydrogen peroxide electrode system [J].
Kim, EJ ;
Haruyama, T ;
Yanagida, Y ;
Kobatake, E ;
Aizawa, M .
ANALYTICA CHIMICA ACTA, 1999, 394 (2-3) :225-231
[9]   A three-enzyme microelectrode sensor for detecting purine release from central nervous system [J].
Llaudet, E ;
Botting, NP ;
Crayston, JA ;
Dale, N .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (01) :43-52
[10]   Amperometric biosensors for sensing of hydrogen peroxide based on electron transfer between horseradish peroxidase and ferrocene as a mediator [J].
Nakabayashi, Y ;
Yoshikawa, H .
ANALYTICAL SCIENCES, 2000, 16 (06) :609-613