The heritability of corneal hysteresis and ocular pulse amplitude - A twin study

被引:52
作者
Carbonaro, Francis [1 ]
Andrew, Toby [2 ]
Mackey, David A. [3 ]
Spector, Tim D. [1 ]
Hammond, Chris J. [1 ,4 ]
机构
[1] Kings Coll London, Sch Med, Twin Res & Genet Epidemiol Unit, London WC2R 2LS, England
[2] Univ London Imperial Coll Sci Technol & Med, Dept Epidemiol & Publ Hlth, London, England
[3] Univ Melbourne, Royal Victorian Eye & Ear Hosp, Ctr Eye Res Australia, Melbourne, Vic, Australia
[4] Bromley Hosp NHS Trust, Princess Royal Univ Hosp, Orpington, England
关键词
D O I
10.1016/j.ophtha.2008.02.011
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To examine the roles of genetic and environmental factors in corneal hysteresis and ocular pulse amplitude by performing a classic twin study. Design: Cross-sectional twin study. Participants and/or Controls: Two hundred sixty-four twin pairs: 135 monozygotic (MZ) and 129 dizygotic (DZ). Methods: Corneal hysteresis was measured using the Reichert Ocular Response Analyzer (ORA; Reichert, Buffalo, NY), and ocular pulse amplitude was measured using the Pascal Dynamic Contour Tonometer (DCT; Swiss Microtechnology AG, Port, Switzerland). Main Outcome Measures: Contribution of genetic and environmental effects on corneal hysteresis and OPA among MZ and DZ twins. Results: The mean corneal hysteresis was of 10.24 +/- 1.54 mmHg and the mean ocular pulse amplitude was 2.88 +/- 0.97 mmHg. The MZ correlations were higher than DZ for both corneal hysteresis and ocular pulse amplitude (correlation coefficients, 0.75:0.42 and 0.59:0.32 for MZ:DZ twins, respectively). Modeling suggested heritability of corneal hysteresis of 0.77 (95% confidence interval [CI], 0.70-0.82), with the remaining proportion of variance because of individual environmental effects of 0.23 (95% CI, 0.18-0.30). For ocular pulse amplitude, the heritability was 0.62 (95% CI, 0.51-0.70), with the remaining proportion of variance the result of individual environmental effects of 0.38 (95% CI, 0.30-0.49). Conclusions: This study demonstrated that additive genetic influences explained most of the individual differences in corneal hysteresis and ocular pulse amplitude among these twins.
引用
收藏
页码:1545 / 1549
页数:5
相关论文
共 35 条
  • [1] Andrew T, 2001, Twin Res, V4, P464, DOI 10.1375/twin.4.6.464
  • [2] Central corneal thickness and corneal hysteresis associated with glaucoma damage
    Congdon, NG
    Broman, AT
    Bandeen-Roche, K
    Grover, D
    Quigley, HA
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 141 (05) : 868 - 875
  • [3] EHLERS N, 1975, ACTA OPHTHALMOL, V53, P34
  • [4] EHLERS N, 1970, Acta Ophthalmologica, V48, P1107
  • [5] The short-term effect of latanoprost on intraocular pressure and pulsatile ocular blood flow
    Georgopoulos, GT
    Diestelhorst, M
    Fisher, R
    Ruokonen, P
    Krieglstein, GK
    [J]. ACTA OPHTHALMOLOGICA SCANDINAVICA, 2002, 80 (01): : 54 - 58
  • [6] Gordon MO, 2002, ARCH OPHTHALMOL-CHIC, V120, P714
  • [7] The influence of corneal hysteresis and corneal resistance factor on the measurement of intraocular pressure
    Hager A.
    Schroeder B.
    Sadeghi M.
    Großherr M.
    Wiegand W.
    [J]. Der Ophthalmologe, 2007, 104 (6): : 484 - 489
  • [8] Changes in corneal hysteresis after clear corneal cataract surgery
    Hager, Annette
    Loge, Kristina
    Fuellhas, Marc-Oliver
    Schroeder, Ernd
    Grossherr, Martin
    Wiegand, Wolfgang
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 144 (03) : 341 - 346
  • [9] Measuring intraocular pressure-adjustments for corneal thickness and new technologies
    Herndon, Leon W.
    [J]. CURRENT OPINION IN OPHTHALMOLOGY, 2006, 17 (02) : 115 - 119
  • [10] Hoffmann Esther M, 2004, BMC Ophthalmol, V4, P4