Semiempirical simulation of x-ray detectors for imaging applications

被引:8
作者
Bontempi, Marco [1 ,2 ]
Bettuzzi, Matteo [3 ]
Visani, Andrea [2 ]
机构
[1] Ist Ortoped Rizzoli, Lab NaBi Nano Biotecnol, I-40136 Bologna, Italy
[2] Ist Ortoped Rizzoli, Lab Biomeccan & Innovaz Tecnol, I-40136 Bologna, Italy
[3] Univ Bologna, Dept Phys, I-40137 Bologna, Italy
关键词
Monte Carlo; x-rays; detector; imaging; MONTE-CARLO-SIMULATION; PHYSICAL-CHARACTERISTICS; COMPUTED-TOMOGRAPHY; CT SYSTEM; BEAM; MAMMOGRAPHY;
D O I
10.1118/1.4767768
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The Monte Carlo (MC) simulation is widely used to design and test complex physical phenomena. This paper presents a simulator of x-ray detector for imaging applications by providing a simple component that can be embedded into a MC code and allowing developers to focus their attention on the primary goals without hanging in the quality of the final output image. Methods: A simplified semiempirical model of x-ray detector was developed and implemented starting from the definition of absorber material and developing scintillator and photoconductor screens and detectors. The validation was done by comparing a Hamamatsu C10900D digital flat panel with a simulation of the same detector using the presented model: MTF, nNPS, and NEQ. Results: The results of validation tests shown excellent agreement of the simulation with respect to the experimental data. The simulation was fast and efficient even in older computers (2004) and it was excellent in newer multicore computers (2010). Conclusions: Comparisons between experimental data and simulations shown that the simulator is able to mimic the output of a real imaging system, and it can have many applications in fields such as industry, medical physics, and teaching. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4767768]
引用
收藏
页码:7677 / 7685
页数:9
相关论文
共 32 条
[1]   A digital detector performance evaluation using Monte Carlo technique [J].
Alcón, EPQ .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 217 (02) :361-367
[2]  
Attix F H, 1986, INTRO RADIOLOGICAL P
[3]  
Ay M. R., 2005, BIOMED TECH, V50, P360
[4]   Development and validation of MCNP4C-based Monte Carlo simulator for fan- and cone-beam x-ray CT [J].
Ay, MR ;
Zaidi, H .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (20) :4863-4885
[5]   Monte Carlo simulation of a computed tomography x-ray tube [J].
Bazalova, Magdalena ;
Verhaegen, Frank .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (19) :5945-5955
[6]  
Bettuzzi M., 2007, P SOC PHOTO-OPT INS, V6616
[7]   Monte-Carlo simulation of industrial radiography images and experimental designs [J].
Bonin, A ;
Chalmond, B ;
Lavayssière, B .
NDT & E INTERNATIONAL, 2002, 35 (08) :503-510
[8]   Monte Carlo simulator of realistic x-ray beam for diagnostic applications [J].
Bontempi, Marco ;
Andreani, Lucia ;
Rossi, Pier Luca ;
Visani, Andrea .
MEDICAL PHYSICS, 2010, 37 (08) :4201-4209
[9]   Electron ionization cross-section calculations for liquid water at high impact energies [J].
Bousis, C. ;
Emfietzoglou, D. ;
Hadjidoukas, P. ;
Nikjoo, H. ;
Pathak, A. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2008, 266 (08) :1185-1192
[10]  
Carlsson C. A., 1996, LIHRADR008 LINK U FA