Metal artifact reduction through MVCBCT and kVCT in radiotherapy

被引:9
作者
Gao Liugang [1 ]
Sun Hongfei [1 ]
Ni Xinye [1 ]
Fang Mingming [2 ]
Cao Zheng [3 ]
Lin Tao [1 ]
机构
[1] Nanjing Med Univ, Peoples Hosp Changzhou 2, Changzhou 213003, Peoples R China
[2] Soochow Univ, Changzhou Canc Hosp, Changzhou 213001, Peoples R China
[3] Anhui Med Univ, Affiliated Hosp 3, Hefei 230000, Anhui, Peoples R China
来源
SCIENTIFIC REPORTS | 2016年 / 6卷
关键词
CT ARTIFACTS; IMAGES; NMAR;
D O I
10.1038/srep37608
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This study proposes a new method for removal of metal artifacts from megavoltage cone beam computed tomography (MVCBCT) and kilovoltage CT (kVCT) images. Both images were combined to obtain prior image, which was forward projected to obtain surrogate data and replace metal trace in the uncorrected kVCT image. The corrected image was then reconstructed through filtered back projection. A similar radiotherapy plan was designed using the theoretical CT image, the uncorrected kVCT image, and the corrected image. The corrected images removed most metal artifacts, and the CT values were accurate. The corrected image also distinguished the hollow circular hole at the center of the metal. The uncorrected kVCT image did not display the internal structure of the metal, and the hole was misclassified as metal portion. Dose distribution calculated based on the corrected image was similar to that based on the theoretical CT image. The calculated dose distribution also evidently differed between the uncorrected kVCT image and the theoretical CT image. The use of the combined kVCT and MVCBCT to obtain the prior image can distinctly improve the quality of CT images containing large metal implants.
引用
收藏
页数:11
相关论文
共 24 条
  • [1] Evaluation of a metal artifact reduction algorithm in CT studies used for proton radiotherapy treatment planning
    Andersson, Karin M.
    Ahnesjo, Anders
    Dahlgren, Christina Vallhagen
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (05): : 112 - 119
  • [2] Metal artifact reduction in CT using tissue-class modeling and adaptive prefiltering
    Bal, Matthieu
    Spies, Lothar
    [J]. MEDICAL PHYSICS, 2006, 33 (08) : 2852 - 2859
  • [3] Correction of CT artifacts and its influence on Monte Carlo dose calculations
    Bazalova, Magdalena
    Beaulieu, Luc
    Palefsky, Steven
    Verhaegen, Frank
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2119 - 2132
  • [4] Changes realized from extended bit-depth and metal artifact reduction in CT
    Glide-Hurst, C.
    Chen, D.
    Zhong, H.
    Chetty, I. J.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [5] Prior-based artifact correction (PBAC) in computed tomography
    Heusser, Thorsten
    Brehm, Marcus
    Ritschl, Ludwig
    Sawall, Stefan
    Kachelriess, Marc
    [J]. MEDICAL PHYSICS, 2014, 41 (02)
  • [6] Generation of hybrid sinograms for the recovery of kV-CT images with metal artifacts for helical tomotherapy
    Jeon, Hosang
    Park, Dahl
    Youn, Hanbean
    Nam, Jiho
    Lee, Jayoung
    Kim, Wontaek
    Ki, Yongkan
    Kim, Yong Ho
    Lee, Ju Hye
    Kim, Dongwon
    Kim, Ho Kyung
    [J]. MEDICAL PHYSICS, 2015, 42 (08) : 4654 - 4667
  • [7] Metal artifact reduction for CT: Development, implementation, and clinical comparison of a generic and a scanner-specific technique
    Joemai, Raoul M. S.
    de Bruin, Paul W.
    Veldkamp, Wouter J. H.
    Geleijns, Jacob
    [J]. MEDICAL PHYSICS, 2012, 39 (02) : 1125 - 1132
  • [8] REDUCTION OF CT ARTIFACTS CAUSED BY METALLIC IMPLANTS
    KALENDER, WA
    HEBEL, R
    EBERSBERGER, J
    [J]. RADIOLOGY, 1987, 164 (02) : 576 - 577
  • [9] Segmentation of artifacts and anatomy in CT metal artifact reduction
    Karimi, Seemeen
    Cosman, Pamela
    Wald, Christoph
    Martz, Harry
    [J]. MEDICAL PHYSICS, 2012, 39 (10) : 5857 - 5868
  • [10] Generation of virtual monochromatic CBCT from dual kV/MV beam projections
    Li, Hao
    Liu, Bo
    Yin, Fang-Fang
    [J]. MEDICAL PHYSICS, 2013, 40 (12)