Partial CO2 Column-Averaged Dry-Air Mixing Ratio from Measurements by Coherent 2-μm Differential Absorption and Wind Lidar with Laser Frequency Offset Locking

被引:19
作者
Ishii, Shoken [1 ]
Mizutani, Kohei [1 ]
Baron, Philippe [1 ]
Iwai, Hironori [1 ]
Oda, Ryoko [1 ]
Itabe, Toshikazu [1 ]
Fukuoka, Hirotake [2 ]
Ishikawa, Takayoshi [3 ]
Koyama, Mizuki [4 ]
Tanaka, Tomoaki [5 ]
Morino, Isamu [5 ]
Uchino, Osamu [5 ]
Sato, Atsushi [6 ]
Asai, Kazuhiro [6 ]
机构
[1] Natl Inst Informat & Commun Technol, Koganei, Tokyo 1848795, Japan
[2] Hamamatsu Photon KK, Hamamatsu, Shizuoka, Japan
[3] Nippon Aleph Co, Yokohama, Kanagawa, Japan
[4] Tokyo Metropolitan Univ, Tokyo 158, Japan
[5] Natl Inst Environm Studies, Tsukuba, Ibaraki, Japan
[6] Tohoku Inst Technol, Sendai, Miyagi 982, Japan
关键词
MU-M; ATMOSPHERIC CO2; FOURIER-TRANSFORM; CARBON-DIOXIDE; SPECTROMETER; SYSTEM;
D O I
10.1175/JTECH-D-11-00180.1
中图分类号
P75 [海洋工程];
学科分类号
0814 ; 081505 ; 0824 ; 082401 ;
摘要
A coherent 2-mu m differential absorption and wind lidar (Co2DiaWiL) with a 2-mu m single-frequency Q-switched laser with laser frequency offset locking was used for long-range CO2 measurement. The frequency stabilization of the single-frequency A on pulsed laser was 1.0 MHz. Experimental horizontal CO2 measurement over a column range of 2.6-5.6 km and 900 shot pairs (1-min integration time) was conducted on 22 October 2009 to examine the detection sensitivity of the Co2DiaWiL. The achieved precision was less than 2.1%. The root-mean-square of the differences between the 30-min CO2 averages measured by the Co2DiaWiL and a ground-based in situ instrument was 0.9% (3.5 ppm). Experimental vertical CO2 measurements were conducted in February 2010 and January and February 2011. The partial CO2 column-averaged dry-air mixing ratios (XCO2) for an altitude between 0.4 and 1.0 km in 2010 and 2011 were 403.2 +/- 4.2 and 405.6 +/- 3.4 ppm, respectively. In the paper, the Co2DiaWiL results were well validated carefully against those of the airborne in situ instrument; they agreed well within the margin of error. The values of XCO2 measured in presence of cirrus clouds near the tropopause (hard target cases) show a difference of less than 4.1 ppm with the airborne measurements performed on 14 February 2010. This result demonstrates the capability of the Co2DiaWiL to measure XCO2 within a precision better than 1%.
引用
收藏
页码:1169 / 1181
页数:13
相关论文
共 24 条
[1]   Pulsed airborne lidar measurements of atmospheric CO2 column absorption [J].
Abshire, James B. ;
Riris, Haris ;
Allan, Graham R. ;
Weaver, Clark J. ;
Mao, Jianping ;
Sun, Xiaoli ;
Hasselbrack, William E. ;
Kawa, S. Randoph ;
Biraud, Sebastien .
TELLUS SERIES B-CHEMICAL AND PHYSICAL METEOROLOGY, 2010, 62 (05) :770-783
[2]   Development of an OPO system at 1.57 μm for integrated path DIAL measurement of atmospheric carbon dioxide [J].
Amediek, A. ;
Fix, A. ;
Wirth, M. ;
Ehret, G. .
APPLIED PHYSICS B-LASERS AND OPTICS, 2008, 92 (02) :295-302
[3]  
[Anonymous], 2010, P ILRC25 25 INT LAS
[4]   The orbiting carbon observatory (OCO) mission [J].
Crisp, D ;
Atlas, RM ;
Breon, FM ;
Brown, LR ;
Burrows, JP ;
Ciais, P ;
Connor, BJ ;
Doney, SC ;
Fung, IY ;
Jacob, DJ ;
Miller, CE ;
O'Brien, D ;
Pawson, S ;
Randerson, JT ;
Rayner, P ;
Salawitch, RJ ;
Sander, SP ;
Sen, B ;
Stephens, GL ;
Tans, PP ;
Toon, GC ;
Wennberg, PO ;
Wofsy, SC ;
Yung, YL ;
Kuang, ZM ;
Chudasama, B ;
Sprague, G ;
Weiss, B ;
Pollock, R ;
Kenyon, D ;
Schroll, S .
TRACE CONSTITUENTS IN THE TROPOSPHERE AND LOWER STRATOSPHERE, 2004, 34 (04) :700-709
[5]   Space-borne remote sensing of CO2, CH4, and N2O by integrated path differential absorption lidar:: a sensitivity analysis [J].
Ehret, G. ;
Kiemle, C. ;
Wirth, M. ;
Amediek, A. ;
Fix, A. ;
Houweling, S. .
APPLIED PHYSICS B-LASERS AND OPTICS, 2008, 90 (3-4) :593-608
[6]   Coherent Doppler lidar measurements of winds in the weak signal regime [J].
Frehlich, R ;
Hannon, SM ;
Henderson, SW .
APPLIED OPTICS, 1997, 36 (15) :3491-3499
[7]   Two-micrometer heterodyne differential absorption lidar measurements of the atmospheric Co2 mixing ratio in the boundary layer [J].
Gibert, Fabien ;
Flamant, Pierre H. ;
Bruneau, Didier ;
Loth, Claude .
APPLIED OPTICS, 2006, 45 (18) :4448-4458
[8]  
Gilbert F., 2008, J ATMOS OCEAN TECH, V25, P1477
[9]   FAST RESONANCE-DETECTION TECHNIQUE FOR SINGLE-FREQUENCY OPERATION OF INJECTION-SEEDED ND-YAG LASERS [J].
HENDERSON, SW ;
YUEN, EH ;
FRY, ES .
OPTICS LETTERS, 1986, 11 (11) :715-717
[10]  
Ishii S., 2007, P 14 COH LAS RAD C, P132