Effect of Negative Air Ions on Fog and Smoke

被引:38
作者
Sawant, V. S. [1 ]
Meena, G. S. [2 ]
Jadhav, D. B. [2 ]
机构
[1] YC Inst Sci, Dept Phys, Satara 415001, Maharashtra, India
[2] Indian Inst Trop Meteorol, Pune 411008, Maharashtra, India
关键词
Air pollutants; NAI generator; Light intensity; Visibility; Removal efficiency; UNIPOLAR; REMOVAL; ENVIRONMENTS; IONIZATION; PARTICLES; VOLATILE; LOSSES;
D O I
10.4209/aaqr.2011.11.0214
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A negative electric discharge voltage generator (NAI Generator) was designed and used to investigate the possibility of reducing (neutralizing) fog, dhoop smoke, and vehicle smoke collected in closed glass containers. The experiment was carried out in a dark room, and two identical glass containers were used. Various sensitivity tests were carried out with fog and smoke. Light intensity was measured for each run as a function of time with and without a negative air ion generator. Negative air ions attach to particulate matter to enhance visibility. At a high negative ion emission rate, the particle mobility becomes sufficient so that particle migration results in their deposition on walls and other indoor surfaces. The performance characteristics of the negative electric discharge generator designed in this work, which produces uni-polar ions by corona discharge at a relatively high emission rate, were evaluated. This device, if operated continuously for six minutes, resulted in the removal of about 93% to 97% of the particles in the glass container, in addition to the natural decay effect. The rate of change of particle removal was higher for fog than for smoke. This study demonstrates that it is possible to neutralize and reduce the concentration of fog and smoke to a significant degree using negative air ions, resulting in increasing visibility in a closed chamber.
引用
收藏
页码:1007 / 1015
页数:9
相关论文
共 43 条
[1]   UNIPOLAR AND BIPOLAR DIFFUSION CHARGING OF ULTRAFINE AEROSOL-PARTICLES [J].
ADACHI, M ;
KOUSAKA, Y ;
OKUYAMA, K .
JOURNAL OF AEROSOL SCIENCE, 1985, 16 (02) :109-123
[2]   Relationship of visibility, aerosol optical thickness and aerosol size distribution in an ageing air mass over South-West Germany [J].
Baeumer, D. ;
Vogel, B. ;
Versick, S. ;
Rinke, R. ;
Moehler, O. ;
Schnaiter, M. .
ATMOSPHERIC ENVIRONMENT, 2008, 42 (05) :989-998
[3]   ON THE EFFECT OF A NEGATIVE ION-GENERATOR AND A MIXING FAN ON THE PLATE-OUT OF RADON DECAY PRODUCTS IN A RADON BOX [J].
BIGU, J .
HEALTH PHYSICS, 1983, 44 (03) :259-266
[4]  
Bohgard M., 1998, J AEROSOL SCI, V29, pS1313
[5]   ON THE INFLUENCE OF THE PHYSICOCHEMICAL PROPERTIES OF AEROSOLS ON THE LIFE-CYCLE OF RADIATION FOGS [J].
BOTT, A .
BOUNDARY-LAYER METEOROLOGY, 1991, 56 (1-2) :1-31
[6]  
COOPER G, 1979, J APPL METEOROL, V18, P57, DOI 10.1175/1520-0450(1979)018<0057:SALIAM>2.0.CO
[7]  
2
[8]   PARTICLE WALL LOSS RATES IN VESSELS [J].
CRUMP, JG ;
FLAGAN, RC ;
SEINFELD, JH .
AEROSOL SCIENCE AND TECHNOLOGY, 1983, 2 (03) :303-309
[9]   On the ionization of air for removal of noxious effluvia (Air ionization of indoor environments for control of volatile and particulate contaminants with nonthermal plasmas generated by dielectric-barrier discharge) [J].
Daniels, SL .
IEEE TRANSACTIONS ON PLASMA SCIENCE, 2002, 30 (04) :1471-1481
[10]  
Frank G., 1998, Contributions to Atmospheric Physics, V71, P65