Towards patient connected imaging with ACROBEAT: Adaptive CaRdiac cOne BEAm computed Tomography

被引:3
作者
Reynolds, Tess [1 ]
Shieh, Chun-Chien [1 ]
Keall, Paul J. [1 ]
O'Brien, Ricky T. [1 ]
机构
[1] Univ Sydney, Fac Med & Hlth, ACRF Image X Inst, Sydney, NSW 2006, Australia
基金
澳大利亚国家健康与医学研究理事会; 英国医学研究理事会;
关键词
cardiac imaging; C-arm computed tomography; dynamic imaging; prospective gating; radiotherapy; intervention radiology; C-ARM CT; CORONARY-ARTERIES; HEART-RATE; MOTION; RECONSTRUCTION; ANGIOGRAPHY; ACQUISITION; ABLATION; PHASES; TIME;
D O I
10.1088/1361-6560/ab03f4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Robotic C-arm cone beam computed tomography (CBCT) systems are playing an increasingly pivotal role in interventional cardiac procedures and high precision radiotherapy treatments. One of the main challenges in any form of cardiac imaging is mitigating the intrinsic motion of the heart, which causes blurring and artefacts in the 3D reconstructed image. Most conventional 3D cardiac CBCT acquisition techniques attempt to combat heart motion through retrospective gating techniques, whereby acquired projections are sorted into the desired cardiac phase after the completion of the scan. However, this results in streaking artefacts and unnecessary radiation exposure to the patient. Here, we present our Adaptive CaRdiac cOne BEAm computed Tomography (ACROBEAT) acquisition protocol that uses the patient's electrocardiogram (ECG) signal to adaptively regulate the gantry velocity and projection time interval in real-time. It enables prospectively gated patient connected imaging in a single sweep of the gantry. The XCAT digital software phantom was used to complete a simulation study to compare ACROBEAT to a conventional multi-sweep retrospective ECG gated acquisition, under a variety of different acquisition conditions. The effect of location and length of the acquisition window and total number of projections acquired on image quality and total scan time were examined. Overall, ACROBEAT enables up to a 5 times average improvement in the contrast-to-noise ratio, a 40% reduction in edge response width and an 80% reduction in total projections acquired compared to conventional multi- sweep retrospective ECG gated acquisition.
引用
收藏
页数:14
相关论文
共 41 条
[21]   Prospective ECG-gated 320 row detector computed tomography: implications for CT angiography and perfusion imaging [J].
Kitagawa, Kakuya ;
Lardo, Albert C. ;
Lima, Joao A. C. ;
George, Richard T. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2009, 25 :201-208
[22]   Towards cardiac C-arm computed tomography [J].
Lauritsch, Guenter ;
Boese, Jan ;
Wigstroem, Lars ;
Kemeth, Herbert ;
Fahrig, Rebecca .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (07) :922-934
[23]   Optimal ECG trigger point in electron-beam CT studies: Three methods for minimizing motion artifacts [J].
Mao, SS ;
Budoff, MJ ;
Bin, L ;
Liu, SCK .
ACADEMIC RADIOLOGY, 2001, 8 (11) :1107-1115
[24]   Radiation Dose Reduction and Coronary Assessability of Prospective Electrocardiogram-Gated Computed Tomography Coronary Angiography Comparison With Retrospective Electrocardiogram-Gated Helical Scan [J].
Maruyama, Takao ;
Takada, Masanori ;
Hasuike, Toshiaki ;
Yoshikawa, Atsushi ;
Namimatsu, Eiji ;
Yoshizumi, Tohru .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (18) :1450-1455
[25]   The impact of the MIT-BIH arrhythmia database [J].
Moody, GA ;
Mark, RG .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 2001, 20 (03) :45-50
[26]   Cardiac C-arm computed tomography using a 3D+time ROI reconstruction method with spatial and temporal regularization [J].
Mory, Cyril ;
Auvray, Vincent ;
Zhang, Bo ;
Grass, Michael ;
Schaefer, Dirk ;
Chen, S. James ;
Carroll, John D. ;
Rit, Simon ;
Peyrin, Francoise ;
Douek, Philippe ;
Boussel, Loic .
MEDICAL PHYSICS, 2014, 41 (02) :021903
[27]   Reducing 4DCBCT imaging time and dose: the first implementation of variable gantry speed 4DCBCT on a linear accelerator [J].
O'Brien, Ricky T. ;
Stankovic, Uros ;
Sonke, Jan-Jakob ;
Keall, Paul J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (11) :4300-4317
[28]   Respiratory motion guided four dimensional cone beam computed tomography: encompassing irregular breathing [J].
O'Brien, Ricky T. ;
Cooper, Benjamin J. ;
Kipritidis, John ;
Shieh, Chun-Chien ;
Keall, Paul J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (03) :579-595
[29]   Optimizing 4D cone beam computed tomography acquisition by varying the gantry velocity and projection time interval [J].
O'Brien, Ricky T. ;
Cooper, Benjamin J. ;
Keall, Paul J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (06) :1705-1723
[30]   Cardiac C-Arm CT: A Unified Framework for Motion Estimation and Dynamic CT [J].
Pruemmer, Marcus ;
Hornegger, Joachim ;
Lauritsch, Guenter ;
Wigstroem, Lars ;
Girard-Hughes, Erin ;
Fahrig, Rebecca .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (11) :1836-1849