The Asymmetric Vascular Stent Efficacy in a Rabbit Aneurysm Model

被引:29
作者
Ionita, Ciprian N. [1 ,2 ,5 ]
Paciorek, Ann M. [1 ,5 ]
Dohatcu, Andreea [4 ]
Hoffmann, Kenneth R. [1 ,4 ,5 ]
Bednarek, Daniel R. [2 ,4 ,5 ]
Kolega, John [3 ]
Levy, Elad I. [1 ,2 ,5 ,6 ]
Hopkins, L. Nelson [1 ,2 ,5 ,6 ]
Rudin, Stephen [1 ,2 ,5 ]
Mocco, J. Duffy [1 ,6 ]
机构
[1] SUNY Buffalo, Sch Med & Biomed Sci, Dept Neurosurg, Buffalo, NY 14260 USA
[2] SUNY Buffalo, Sch Med & Biomed Sci, Dept Radiol, Buffalo, NY 14260 USA
[3] SUNY Buffalo, Sch Med & Biomed Sci, Dept Pathol, Buffalo, NY 14260 USA
[4] SUNY Buffalo, Sch Med & Biomed Sci, Dept Phys, Buffalo, NY 14260 USA
[5] SUNY Buffalo, Sch Med & Biomed Sci, Toshiba Stroke Res Ctr, Buffalo, NY 14260 USA
[6] Kaleida Hlth, Millard Fillmore Gates Hosp, Dept Neurosurg, Buffalo, NY USA
关键词
aneurysm; asymmetrical; elastase; hemodynamics; modification; stent model; vascular; NECKED INTRACRANIAL ANEURYSMS; CEREBRAL ANEURYSMS; NEUROFORM STENT; SACCULAR ANEURYSMS; FLOW MODIFICATION; FOLLOW-UP; EXPERIENCE; ANGIOGRAPHY; POROSITY; COILS;
D O I
10.1161/STROKEAHA.108.524124
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose-Development of hemodynamic modifying devices to treat intracranial aneurysms is an active area of research. The asymmetrical vascular stent (AVS), a stent containing a low-porosity patch, is such device. We evaluate AVS efficacy in an in vivo intracranial aneurysm model. Methods-We created 24 elastase rabbit model aneurysms: 13 treated with the AVS, 5 treated with standard coronary stents, and 6 untreated controls. Four weeks after treatment, aneurysms underwent follow-up angiography, cone-beam micro-CT, histological evaluation, and selective electron microscopy scanning. Results-Four rabbits died early in the study: 3 during AVS treatment and 1 control ( secondary to intraprocedural vessel injury and an unrelated tumor, respectively). AVS-treated aneurysms exhibited very weak or no aneurysm flow immediately after treatment and no flow in all aneurysms at follow-up. Standard stent-treated aneurysms showed flow both after treatment (5/5) and at follow- up (3/5). All control aneurysms remained patent during the study. Micro-CT scans showed: 9 of 9 scanned AVS aneurysms were occluded, 6 of 9 AVS were ideally placed, and 3 of 9 low-porosity region partially covered the aneurysm neck; standard stent-treated aneurysms were 1 of 5 occluded, 2 of 5 patent, and 2 of 5 partially patent. Histology results demonstrated: for AVS-treated aneurysms, advanced thrombus organization in the (9/9); for standard stent-treated aneurysms, (1/4) no thrombus, (2/4) partially thrombosed, and (1/4) fully thrombosed; for control aneurysms (4/4), no thrombus. Conclusion-The use of AVS shows promise as a viable new therapeutic in intracranial aneurysm treatment. These data encourage further investigation and provide substantial support to the AVS concept. ( Stroke. 2009; 40: 959-965.)
引用
收藏
页码:959 / 965
页数:7
相关论文
共 34 条
[1]  
Akpek S, 2005, AM J NEURORADIOL, V26, P1223
[2]   Creation of saccular aneurysms in the rabbit: A model suitable for testing endovascular devices [J].
Altes, TA ;
Cloft, HJ ;
Short, JG ;
DeGast, A ;
Do, HM ;
Helm, GA ;
Kallmes, DF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (02) :349-354
[3]   Endovascular occlusion of wide-necked aneurysms with a new intracranial microstent (neuroform) and detachable coils [J].
Benitez, RP ;
Silva, MT ;
Klem, J ;
Veznedaroglu, E ;
Rosenwasser, RH .
NEUROSURGERY, 2004, 54 (06) :1359-1367
[4]   Biocompatibility aspects of new stent technology [J].
Bertrand, OF ;
Sipehia, R ;
Mongrain, R ;
Rodés, JR ;
Tardif, JC ;
Bilodeau, L ;
Côté, G ;
Bourassa, MG .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (03) :562-571
[5]   Neuroform stent-assisted coil embolization of wide-neck intracranial aneurysms: Strategies in stent deployment and midterm follow-up [J].
Biondi, Alessandra ;
Janardhan, Vallabh ;
Katz, Jeffrey M. ;
Salvaggio, Kimberly ;
Riina, Howard A. ;
Gobin, Y. Pierre .
NEUROSURGERY, 2007, 61 (03) :460-468
[6]  
Cebral JR, 2005, AM J NEURORADIOL, V26, P2550
[7]   Double-stent method: therapeutic alternative for small wide-necked aneurysms [J].
Doerfler, A ;
Wanke, I ;
Egelhof, T ;
Stolke, D ;
Forsting, M .
JOURNAL OF NEUROSURGERY, 2004, 100 (01) :150-154
[8]   Regional time density curves (R-TDC) derived from angiographic sequences for analysis of aneurysmal flow modification resulting from endovascular image-guided interventions [J].
Dohatcu, A. C. ;
Ionita, C. N. ;
Sherman, J. R. ;
Rangwalla, H. S. ;
Bednarek, D. R. ;
Hoffman, K. ;
Rudin, S. .
MEDICAL PHYSICS, 2007, 34 (06) :2367-2367
[9]   Usefulness of the neuroform stent for the treatment of cerebral aneurysms: Results at initial (3-6-mo) follow-up [J].
Fiorella, D ;
Albuquerque, FC ;
Deshmukh, VR ;
McDougall, CG .
NEUROSURGERY, 2005, 56 (06) :1191-1201
[10]   Preliminary experience using the neuroform stent for the treatment of cerebral aneurysms [J].
Fiorella, D ;
Albuquerque, FC ;
Han, P ;
McDougall, CG .
NEUROSURGERY, 2004, 54 (01) :6-16