Analysis on energy efficiency of an integrated heat pipe system in data centers

被引:56
作者
Wang, Zhenying [1 ]
Zhang, Xiaotong [1 ]
Li, Zhen [1 ]
Luo, Ming [1 ]
机构
[1] Tsinghua Univ, Dept Engn Mech, Minist Educ, Key Lab Thermal Sci & Power Engn, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
Data center; Integrated system; Heat pipe; Energy efficiency; Climate; AIR-SIDE ECONOMIZERS; 2-PHASE THERMOSIPHON LOOP; CONDITIONER;
D O I
10.1016/j.applthermaleng.2015.07.078
中图分类号
O414.1 [热力学];
学科分类号
摘要
Energy saving in data centers is increasingly important along with the rapidly developing IT industry. This paper proposes an integrated cooling system for data centers which combines a heat pipe cooling cycle and a vapor compression cooling cycle. The operating mode of the system changes with the outdoor temperature. Key problems of the integrated system were solved such as the mix of the refrigerant and lubricant, the match of heat exchange areas and the durability of valves. A thermal equilibrium test was carried out to evaluate the system performance. Thermodynamic analyses based on experimental data show that the PUE (Power Usage Effectiveness) of data centers using the integrated heat pipe system can be 0.3 lower than using the conventional air cooling systems in cold areas like Beijing and Harbin. The energy saving potential of the integrated heat pipe system varies with seasonal and regional climate changes. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:937 / 944
页数:8
相关论文
共 28 条
[21]   Two-phase thermosyphon loop for cooling outdoor telecommunication equipments [J].
Samba, Ahmadou ;
Louahlia-Gualous, Hasna ;
Le Masson, Stephane ;
Noerterhaeuser, David .
APPLIED THERMAL ENGINEERING, 2013, 50 (01) :1351-1360
[22]   Potential of air-side economizers for data center cooling: A case study for key Australian cities [J].
Siriwardana, Jayantha ;
Jayasekara, Saliya ;
Halgamuge, Saman K. .
APPLIED ENERGY, 2013, 104 :207-219
[23]   A combined cooling solution for high heat density data centers using multi-stage heat pipe loops [J].
Tian, Hao ;
He, Zhiguang ;
Li, Zhen .
ENERGY AND BUILDINGS, 2015, 94 :177-188
[24]   Integrated system of mechanical refrigeration and thermosyphon for free cooling of data centers [J].
Zhang, Hainan ;
Shao, Shuangquan ;
Xu, Hongbo ;
Zou, Huiming ;
Tian, Changqing .
APPLIED THERMAL ENGINEERING, 2015, 75 :185-192
[25]   Free cooling of data centers: A review [J].
Zhang, Hainan ;
Shao, Shuangquan ;
Xu, Hongbo ;
Zou, Huiming ;
Tian, Changqing .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 35 :171-182
[26]   Heat recovery from Internet data centers for space heating based on an integrated air conditioner with thermosyphon [J].
Zhang, Penglei ;
Wang, Baolong ;
Wu, Wei ;
Shi, Wenxing ;
Li, Xianting .
RENEWABLE ENERGY, 2015, 80 :396-406
[27]  
Zhang X. T., 2014, 13 INT C SUST EN TEC
[28]   Modelling and applications of annual energy-using simulation module of separated heat pipe heat exchanger [J].
Zhu, Dan-dan ;
Yan, Da ;
Li, Zhen .
ENERGY AND BUILDINGS, 2013, 57 :26-33