A Highly Sensitive and Selective OFF-ON Fluorescent Sensor for Cadmium in Aqueous Solution and Living Cell

被引:326
作者
Cheng, Tanyu [1 ]
Xu, Yuifang [1 ]
Zhang, Shenyi [1 ]
Zhu, Weiping [1 ]
Qian, Xuhong [1 ]
Duan, Liping [1 ]
机构
[1] E China Univ Sci & Technol, Sch Pharm, State Key Lab Bioreactor Engn, Shanghai Key Lab Chem Biol, Shanghai 200237, Peoples R China
基金
中国国家自然科学基金; 国家高技术研究发展计划(863计划);
关键词
D O I
10.1021/ja806928n
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A highly selective and sensitive OFF-ON fluorescent sensor 1, employing the PET mechanism, was designed and synthesized. It could be used to detect Cd2+ ion in aqueous solution and to image Cd2+ ion in living cells. The fluorescence intensity significantly enhanced about 195-fold and the quantum yield increased almost 100-fold. Moreover the fluorescence intensity of 1 increased linearly with high sensitivity (0-1 mu M) toward Cd2+.
引用
收藏
页码:16160 / +
页数:3
相关论文
共 58 条
[1]   Flow injection on-line hydrophobic sorbent extraction for flame atomic absorption spectrometric determination of cadmium in water samples [J].
Anthemidis, Aristidis N. ;
Karapatouchas, Christos-Paraskevas P. .
MICROCHIMICA ACTA, 2008, 160 (04) :455-460
[2]   A simple strategy for quantum dot assisted selective detection of cadmium ions [J].
Banerjee, Subhash ;
Kara, Soumitra ;
Santra, Swadeshmukul .
CHEMICAL COMMUNICATIONS, 2008, (26) :3037-3039
[3]   Microbead chemical switches: An approach to detection of reactive organophosphate chemical warfare agent vapors [J].
Bencic-Nagale, S ;
Sternfeld, T ;
Walt, DR .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2006, 128 (15) :5041-5048
[4]   Efficient immobilization of a cadmium chemosensor in a thin film: Generation of a cadmium sensor prototype [J].
Bronson, RT ;
Michaelis, DJ ;
Lamb, RD ;
Husseini, GA ;
Farnsworth, PB ;
Linford, MR ;
Izatt, RM ;
Bradshaw, JS ;
Savage, PB .
ORGANIC LETTERS, 2005, 7 (06) :1105-1108
[5]   Luminescent sensors and switches in the early 21st century [J].
Callan, JF ;
de Silva, AP ;
Magri, DC .
TETRAHEDRON, 2005, 61 (36) :8551-8588
[6]   Determination of cadmium in marine waters: on-line preconcentration and flow-through fluorescence detection [J].
Charles, S ;
Yunus, S ;
Dubois, F ;
Vander Donckt, E .
ANALYTICA CHIMICA ACTA, 2001, 440 (01) :37-43
[7]   Design of optical switches as metabolic indicators: New fluorogenic probes for monoamine oxidases (MAO A and B) [J].
Chen, G ;
Yee, DJ ;
Gubernator, NG ;
Sames, D .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2005, 127 (13) :4544-4545
[8]   A new reverse PET chemosensor and its chelatoselective aromatic cadmiation [J].
Choi, M ;
Kim, M ;
Lee, KD ;
Han, KN ;
Yoon, IA ;
Chung, HJ ;
Yoon, J .
ORGANIC LETTERS, 2001, 3 (22) :3455-3457
[9]   Enhanced metal ion selectivity of 2,9-di-(pyrid-2-yl)-1,10-phenanthroline and its use as a fluorescent sensor for cadmium(II) [J].
Cockrell, Gregory M. ;
Zhang, Gang ;
VanDerveer, Donald G. ;
Thummel, Randolph P. ;
Hancock, Robert D. .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2008, 130 (04) :1420-1430
[10]   Ion sensing coupled to resonance energy transfer: A highly selective and sensitive ratiometric fluorescent chemosensor for Ag(I) by a modular approach [J].
Coskun, A ;
Akkaya, EU .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2005, 127 (30) :10464-10465