CCD and offset after Nanos short stem in total hip arthroplasty

被引:13
作者
Ettinger, M. [1 ]
Ettinger, P. [2 ]
Ezechieli, M. [1 ]
Bueermann, S. [1 ]
Budde, S. [1 ]
Calliess, T. [1 ]
Petri, M. [4 ]
Thorey, F. [3 ]
机构
[1] Hannover Med Sch, Dept Orthopaed Surg, D-30625 Hannover, Germany
[2] Melle Christian Clin, Dept Orthopaed Surg, Melle, Germany
[3] ATOS Hosp Heidelberg, Ctr Hip Knee & Foot Surg, Heidelberg, Germany
[4] Hannover Med Sch, Dept Traumatol, D-30625 Hannover, Germany
关键词
Short hip stem; Nanos; total hip arthrosplasty; radiology; FEMORAL COMPONENT; REPLACEMENT; PROSTHESIS;
D O I
10.3233/THC-130716
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
BACKGROUND: Many short stems for total hip arthroplasty have been introduced by the manufacturers only during the last decade. One of them is the Nanos short stem (Smith and Nephew, Marl, Germany). The development of short stems was aimed at preserving bone and soft tissue by utilizing a minimally invasive approach, thus allowing a quick return to an active life. It was purpose of this study to evaluate the radiological changes after using this device. METHODS: We present the radiological results of 202 cementless THAs which were performed in 172 patients using the Nanos stem. Radiological evaluation was performed using standing anterior-posterior (AP) and lateral radiographs of the proximal femur preoperatively, postoperatively and during the follow up. We analyzed the preoperative and postoperativ CCD angle, the subsisdence, preoperative and postoperative offset, osteolysis, bone resorption, increased density, neocortex and periarthricular ossifications. RESULTS: One stem had to be revised due to subsidence four days after implantation. Two cups (BiconPlus, Smith and Nephew, Marl, Germany) had to be revised during the time of follow up due to an aseptic cup loosening. Two stems showed radiolucent lines at the implant-bone-interface at the last follow-up. An increase of bone density could be detected in 18 hips (8.9%). 14 hips showed periarticular ossifications. Measurable subsidence was detected in a total of four stems (1.9%). The preoperative neck-shaft-angle angle was 133.8 +/- 4.4 degrees(range: 118.5-146.2) and the neck-shaft-angle angle at the time of follow up was 134.6 +/- 4.3 degrees (range: 123.3-147; P < 0.05). The preoperative and postoperative offset changed from 109.3 +/- 11.9 mm (range: 80.9-131.6) to 109.7 +/- 12.3 mm (range: 79.7-155.6; P < 0.05). CONCLUSION: In summary, this study shows that a correct anatomical reconstruction is possible with a device of this design. The outcome is comparable to that of other short stems. Further studies should be performed in a prospective and randomized design to evaluate the advantage of such a device with a higher level of evidence.
引用
收藏
页码:149 / 155
页数:7
相关论文
共 31 条
[1]   The prophylaxis and treatment of heterotopic ossification following lower limb arthroplasty [J].
Board, T. N. ;
Karva, A. ;
Board, R. E. ;
Gambhir, A. K. ;
Porter, M. L. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (04) :434-440
[2]   Two-Year Results of a Modular Short Hip Stem Prosthesis - A Prospective Study [J].
Braun, A. ;
Sabah, A. .
ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2009, 147 (06) :700-706
[3]   Mid-term results of 155 patients treated with a collum femoris preserving (CFP) short stem prosthesis [J].
Briem, Daniel ;
Schneider, Michael ;
Bogner, Nicole ;
Botha, Nadine ;
Gebauer, Matthias ;
Gehrke, Thorsten ;
Schwantes, Bernd .
INTERNATIONAL ORTHOPAEDICS, 2011, 35 (05) :655-660
[4]   ECTOPIC OSSIFICATION FOLLOWING TOTAL HIP-REPLACEMENT - INCIDENCE AND A METHOD OF CLASSIFICATION [J].
BROOKER, AF ;
BOWERMAN, JW ;
ROBINSON, RA ;
RILEY, LH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1973, A 55 (08) :1629-1632
[5]   TOTAL HIP-REPLACEMENT IN PATIENTS YOUNGER THAN 30 YEARS OLD - A 5-YEAR FOLLOW-UP-STUDY [J].
CHANDLER, HP ;
REINECK, FT ;
WIXSON, RL ;
MCCARTHY, JC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1981, 63 (09) :1426-1434
[6]   External beam radiation helps prevent heterotopic bone formation in patients with a history of heterotopic ossification [J].
Chao, Samuel T. ;
Lee, Shih-Yuan ;
Borden, Lester S. ;
Joyce, Michael J. ;
Krebs, Viktor E. ;
Suh, John H. .
JOURNAL OF ARTHROPLASTY, 2006, 21 (05) :731-736
[7]   Maintenance of bone mineral density after implantation of a femoral neck hip prosthesis [J].
Decking, Ralf ;
Rokahr, Christoph ;
Zurstegge, Matthias ;
Simon, Ulrich ;
Decking, Jens .
BMC MUSCULOSKELETAL DISORDERS, 2008, 9 (1)
[8]   Mid-term results of the cementless femoral neck prosthesis CUT [J].
Ender, S. A. ;
Machner, A. ;
Hubbe, J. ;
Pap, G. ;
Neumann, H. W. .
ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2006, 144 (05) :477-483
[9]   The accuracy and reproducibility of radiographic assessment of stress-shielding - A postmortem analysis [J].
Engh, CA ;
McAuley, JP ;
Sychterz, CJ ;
Sacco, ME ;
Engh, CA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (10) :1414-1420
[10]   The NANOS short stem in total hip arthroplasty: a mid term follow-up [J].
Ettinger, Max ;
Ettinger, Peter ;
Lerch, Matthias ;
Radtke, Kerstin ;
Budde, Stefan ;
Ezechieli, Marco ;
Becher, Christoph ;
Thorey, Fritz .
HIP INTERNATIONAL, 2011, 21 (05) :583-586