Markerless Motion Capture and Measurement of Hand Kinematics: Validation and Application to Home-Based Upper Limb Rehabilitation

被引:73
作者
Metcalf, Cheryl D. [1 ]
Robinson, Rebecca [2 ]
Malpass, Adam J. [2 ]
Bogle, Tristan P. [2 ]
Dell, Thomas A. [2 ]
Harris, Chris [3 ]
Demain, Sara H. [1 ]
机构
[1] Univ Southampton, Fac Hlth Sci, Southampton SO17 1BJ, Hants, England
[2] Univ Southampton, Dept Elect & Comp Sci, Southampton SO17 1BJ, Hants, England
[3] ROKE Manor Res Ltd, Romsey SO51 0ZN, Hants, England
基金
美国国家卫生研究院;
关键词
Hand kinematics; markerless; Microsoft Kinect; telerehabilitation; MODEL; RELIABILITY; RANGE;
D O I
10.1109/TBME.2013.2250286
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Dynamic movements of the hand, fingers, and thumb are difficult to measure due to the versatility and complexity of movement inherent in function. An innovative approach to measuring hand kinematics is proposed and validated. The proposed system utilizes the Microsoft Kinect and goes beyond gesture recognition to develop a validated measurement technique of finger kinematics. The proposed system adopted landmark definition (validated through ground truth estimation against assessors) and grip classification algorithms, including kinematic definitions (validated against a laboratory-based motion capture system). The results of the validation show 78% accuracy when identifying specific markerless landmarks. In addition, comparative data with a previously validated kinematic measurement technique show accuracy of MCP +/- 10 degrees (average absolute error (AAE) = 2.4 degrees), PIP +/- 12 degrees (AAE = 4.8 degrees), and DIP +/- 11 degrees (AAE = 4.8 degrees). These results are notably better than clinically based alternative manual measurement techniques. The ability to measure hand movements, and therefore functional dexterity, without interfering with underlying composite movements, is the paramount objective to any bespoke measurement system. The proposed system is the first validated markerless measurement system using the Microsoft Kinect that is capable of measuring finger joint kinematics. It is suitable for home-based motion capture for the hand and, therefore, achieves this objective.
引用
收藏
页码:2184 / 2192
页数:9
相关论文
共 45 条
  • [1] Alnowami M., 2012, P SPIE, V8316
  • [2] [Anonymous], 4 INT S 3D DAT PROC
  • [3] A comparison of ground truth estimation methods
    Biancardi, Alberto M.
    Jirapatnakul, Artit C.
    Reeves, Anthony P.
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2010, 5 (03) : 295 - 305
  • [4] Kinematic performance of a six degree-of-freedom hand model (6DHand) for use in occupational biomechanics
    Buczek, Frank L.
    Sinsel, Erik W.
    Gloekler, Daniel S.
    Wimer, Bryan M.
    Warren, Christopher M.
    Wu, John Z.
    [J]. JOURNAL OF BIOMECHANICS, 2011, 44 (09) : 1805 - 1809
  • [5] Byron K., 2009, THESIS IOWA STATE U
  • [6] Multi-finger coordination in healthy subjects and stroke patients: a mathematical modelling approach
    Carpinella, Ilaria
    Jonsdottir, Johanna
    Ferrarin, Maurizio
    [J]. JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2011, 8
  • [7] Accuracy and Reliability of Three Different Techniques for Manual Goniometry for Wrist Motion: A Cadaveric Study
    Carter, Timothy I.
    Pansy, Brian
    Wolff, Aviva L.
    Hillstrom, Howard J.
    Backus, Sherry I.
    Lenhoff, Mark
    Wolfe, Scott W.
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2009, 34A (08): : 1422 - 1428
  • [8] HandPuppet3D: Motion capture and analysis for character animation
    Condell, Joan
    Moore, George
    [J]. ARTIFICIAL INTELLIGENCE REVIEW, 2009, 31 (1-4) : 45 - 59
  • [9] A markerless motion capture system to study musculoskeletal biomechanics:: Visual hull and simulated annealing approach
    Corazza, S.
    Mundermann, L.
    Chaudhari, A. M.
    Demattio, T.
    Cobelli, C.
    Andriacchi, T. P.
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2006, 34 (06) : 1019 - 1029
  • [10] Cordella F., 2012, 4 IEEE RAS EMBS INT