Imaging at ultrahigh magnetic fields: History, challenges, and solutions

被引:102
作者
Ugurbil, Kamil [1 ]
机构
[1] Univ Minnesota, Sch Med, CMRR, Minneapolis, MN 55455 USA
关键词
HUMAN VISUAL-CORTEX; TO-NOISE RATIO; SPIN-ECHO FMRI; SIMULTANEOUS MULTISLICE EXCITATION; VIVO H-1-NMR SPECTROSCOPY; OCULAR DOMINANCE COLUMNS; CEREBRAL METABOLIC-RATE; BRAIN HEATING DECREASE; INDUCED SIGNAL CHANGES; HIGH-RESOLUTION FMRI;
D O I
10.1016/j.neuroimage.2017.07.007
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Following early efforts in applying nuclear magnetic resonance (NMR) spectroscopy to study biological processes in intact systems, and particularly since the introduction of 4 T human scanners circa 1990, rapid progress was made in imaging and spectroscopy studies of humans at 4 T and animal models at 9.4 T, leading to the introduction of 7 T and higher magnetic fields for human investigation at about the turn of the century. Work conducted on these platforms has provided numerous technological solutions to challenges posed at these ultrahigh fields, and demonstrated the existence of significant advantages in signal-to-noise ratio and biological information content. Primary difference from lower fields is the deviation from the near field regime at the radiofrequencies (RF) corresponding to hydrogen resonance conditions. At such ultrahigh fields, the RF is characterized by attenuated traveling waves in the human body, which leads to image non-uniformities for a given sample-coil configuration because of destructive and constructive interferences. These non-uniformities were initially considered detrimental to progress of imaging at high field strengths. However, they are advantageous for parallel imaging in signal reception and transmission, two critical technologies that account, to a large extend, for the success of ultrahigh fields. With these technologies and improvements in instrumentation and imaging methods, today ultrahigh fields have provided unprecedented gains in imaging of brain function and anatomy, and started to make inroads into investigation of the human torso and extremities. As extensive as they are, these gains still constitute a prelude to what is to come given the increasingly larger effort committed to ultrahigh field research and development of ever better instrumentation and techniques. (C) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:7 / 32
页数:26
相关论文
共 278 条
[91]   Robust fully automated shimming of the human brain for high-field 1H spectroscopic imaging [J].
Hetherington, Hoby P. ;
Chu, Wen-Jang ;
Gonen, Oded ;
Pan, Jullie W. .
MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (01) :26-33
[92]   Regional Blood Flow in the Normal and Ischemic Brain Is Controlled by Arteriolar Smooth Muscle Cell Contractility and Not by Capillary Pericytes [J].
Hill, Robert A. ;
Tong, Lei ;
Yuan, Peng ;
Murikinati, Sasidhar ;
Gupta, Shobhana ;
Grutzendler, Jaime .
NEURON, 2015, 87 (01) :95-110
[93]   Depth-resolved optical imaging and microscopy of vascular compartment dynamics during somatosensory stimulation [J].
Hillman, Elizabeth M. C. ;
Devor, Anna ;
Bouchard, Matthew B. ;
Dunn, Andrew K. ;
Krauss, G. W. ;
Skoch, Jesse ;
Bacskai, Brian J. ;
Dale, Anders M. ;
Boas, David A. .
NEUROIMAGE, 2007, 35 (01) :89-104
[94]  
Hoogenraad FGC, 2001, MAGNET RESON MED, V45, P233, DOI 10.1002/1522-2594(200102)45:2<233::AID-MRM1032>3.0.CO
[95]  
2-W
[96]  
Hoogenraad FGC, 1999, JMRI-J MAGN RESON IM, V9, P475, DOI 10.1002/(SICI)1522-2586(199903)9:3<475::AID-JMRI17>3.0.CO
[97]  
2-Y
[98]   THE FIELD-DEPENDENCE OF NMR IMAGING .2. ARGUMENTS CONCERNING AN OPTIMAL FIELD-STRENGTH [J].
HOULT, DI ;
CHEN, CN ;
SANK, VJ .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (05) :730-746
[99]   SENSITIVITY OF THE ZEUGMATOGRAPHIC EXPERIMENT INVOLVING HUMAN SAMPLES [J].
HOULT, DI ;
LAUTERBUR, PC .
JOURNAL OF MAGNETIC RESONANCE, 1979, 34 (02) :425-433
[100]  
Hoult DI, 2000, J MAGN RESON IMAGING, V12, P46, DOI 10.1002/1522-2586(200007)12:1<46::AID-JMRI6>3.0.CO