Four-year clinical evaluation of a self-adhesive luting agent for ceramic inlays

被引:57
作者
Peumans, Marleen [1 ]
Voet, M. [1 ]
De Munck, J. [1 ]
Van Landuyt, K. [1 ]
Van Ende, A. [1 ]
Van Meerbeek, B. [1 ]
机构
[1] Katholieke Univ Leuven, Sch Dent Oral Pathol & Maxillofacial Surg, Dept Conservat Dent, Leuven BIOMAT Res Cluster, B-3000 Louvain, Belgium
关键词
Glass ceramics; Adhesive inlays; Luting composite; Self-adhesive; Clinical trial; MICROTENSILE BOND STRENGTH; IPS EMPRESS INLAYS; RESIN CEMENTS; ENAMEL; PERFORMANCE; COMPOSITE; DENTIN; ONLAYS; RESTORATIONS; CROWNS;
D O I
10.1007/s00784-012-0762-9
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this randomized controlled clinical trial was to evaluate the 4-year clinical performance of a self-adhesive resin cement, RelyX Unicem (3M ESPE), used for cementation of ceramic inlays. In addition, the influence of selectively acid-etching enamel prior to luting on the clinical performance of the restorations was assessed. Sixty-two IPS Empress 2 inlays/onlays were placed in 31 patients by two experienced clinicians. The restorations were luted with RelyX Unicem with (=experimental group: E) or without (=control group: NE) prior enamel etching with phosphoric acid. At baseline, 6 months, and 1, 2, and 4 years after placement, the restorations were assessed by two calibrated investigators using modified USPHS criteria. Ten selected samples of each group were investigated under SEM regarding morphological changes at the cement-inlay interface. The recall rate at 4 years was 97 %. Two restorations (1 E, 1 NE) were lost, and one (E) had to be replaced due to inlay and tooth fracture resulting in a survival rate of 95 %. No significant differences between the experimental and control group were noticed regarding all criteria (McNemar, p < 0.05). An obvious deterioration in marginal integrity was observed after 4 years as only 5 % (E = 7 %; NE = 3 %) of the restorations exhibited an excellent marginal adaptation. In 90 % of the restorations small, still clinically acceptable marginal deficiencies were observed. SEM of the luting gap showed an increased wear of the RelyX Unicem cement over the 4-year period. The self-adhesive luting cement RelyX Unicem can be recommended for bonding of ceramic inlays/onlays. Additional selective enamel etching does not improve the clinical performance of the restorations within the 4-year period. The self-adhesive resin composite RelyX Unicem showed acceptable clinical performance after 4 years of clinical service.
引用
收藏
页码:739 / 750
页数:12
相关论文
共 65 条
  • [1] Bond strength of a new universal self-adhesive resin luting cement to dentin and enamel
    Abo-Hamar, SE
    Hiller, KA
    Jung, H
    Federlin, M
    Friedl, KH
    Schmalz, G
    [J]. CLINICAL ORAL INVESTIGATIONS, 2005, 9 (03) : 161 - 167
  • [2] Fracture toughness and hardness evaluation of three pressable all-ceramic dental materials
    Albakry, M
    Guazzato, M
    Swain, MV
    [J]. JOURNAL OF DENTISTRY, 2003, 31 (03) : 181 - 188
  • [3] Marginal adaptation of three self-adhesive resin cements vs. a well-tried adhesive luting agent
    Behr, M.
    Hansmann, M.
    Rosentritt, M.
    Handel, G.
    [J]. CLINICAL ORAL INVESTIGATIONS, 2009, 13 (04) : 459 - 464
  • [4] In vitro wear gap formation of self-adhesive resin cements: A CLSM evaluation
    Belli, Renan
    Pelka, Matthias
    Petschelt, Anselm
    Lohbauer, Ulrich
    [J]. JOURNAL OF DENTISTRY, 2009, 37 (12) : 984 - 993
  • [5] Bonding Efficacy of New Self-etching, Self-adhesive Dual-curing Resin Cements to Dental Enamel
    Benetti, Paula
    Boas Fernandes Junior, Virgilio Vilas
    Gomes Torres, Carlos Rocha
    Pagani, Clovis
    [J]. JOURNAL OF ADHESIVE DENTISTRY, 2011, 13 (03) : 231 - 234
  • [6] Clinical and SEM evaluation of all-ceramic chair-side CAD/CAM-generated partial crowns
    Bindl, A
    Mörmann, WH
    [J]. EUROPEAN JOURNAL OF ORAL SCIENCES, 2003, 111 (02) : 163 - 169
  • [7] Fracture behavior of lithia disilicate- and leucite-based ceramics
    Bona, AD
    Mecholsky, JJ
    Anusavice, KJ
    [J]. DENTAL MATERIALS, 2004, 20 (10) : 956 - 962
  • [8] Bonding potential of self-adhesive luting agents used at different temperatures to lute composite onlays
    Cantoro, Amerigo
    Goracci, Cecilia
    Carvalho, Carlos Augusto
    Coniglio, Ivanovic
    Ferrari, Marco
    [J]. JOURNAL OF DENTISTRY, 2009, 37 (06) : 454 - 461
  • [9] The Influence of Luting Systems on the Microtensile Bond Strength of Dentin to Indirect Resin-based Composite and Ceramic Restorations
    D'Arcangelo, C.
    De Angelis, F.
    D'Amario, M.
    Zazzeroni, S.
    Ciampoli, C.
    Caputi, S.
    [J]. OPERATIVE DENTISTRY, 2009, 34 (03) : 328 - 336
  • [10] Bonding of an auto-adhesive luting material to enamel and dentin
    De Munck, J
    Vargas, M
    Van Landuyt, K
    Hikita, K
    Lambrechts, P
    Van Meerbeek, B
    [J]. DENTAL MATERIALS, 2004, 20 (10) : 963 - 971